SearcharxivSearch

arXiv subjects

Lukas Gerritzen

Publications and source records attributed to Lukas Gerritzen.

3 recordsLinked to original sources

Performance of an LYSO-Based Active Converter for a Conversion Spectrometer aiming for 52.8 MeV photon detection in Future $μ^+ \to e^+ γ$ Search Experiments

To facilitate future $μ^+ \to e^+ γ$ search experiments with a branching-ratio sensitivity of $10^{-15}$, we are developing a conversion spectrometer that incorporates an active LYSO converter. The converter generates $e^+e^-$ pairs from incident photons while simultaneously measuring their energy deposition and timing, thereby enabling precise reconstruction of 52.8 MeV photons. The design goals include a time resolution of 30 ps and an energy resolution of 200 keV for the detection of 52.8 MeV photons. Based on simulation studies, we optimized the converter thickness and segment dimensions, followed by the fabrication of prototype LYSO segments. The single-MIP detection performance of these prototypes was evaluated using an electron beam at the KEK PF-AR test beamline. The prototypes demonstrated excellent performance, achieving a time resolution of 25 ps and a light yield of $10^4$ photoelectrons, both of which significantly exceed the design requirements.

physics.ins-det

Photon energy reconstruction with the MEG II liquid xenon calorimeter

The MEG II experiment searches for a charged-lepton-flavour-violating $μ\to e γ$ with the target sensitivity of $6 \times 10^{-14}$. A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is $3\text{-}5 \times 10^{7}~\text{s}^{-1}$, multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of the energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.

physics.ins-det

The Mu3e Data Acquisition

The Mu3e experiment aims to find or exclude the lepton flavour violating decay $μ^+\to e^+e^-e^+$ with a sensitivity of one in 10$^{16}$ muon decays. The first phase of the experiment is currently under construction at the Paul Scherrer Institute (PSI, Switzerland), where beams with up to 10$^8$ muons per second are available. The detector will consist of an ultra-thin pixel tracker made from High-Voltage Monolithic Active Pixel Sensors (HV-MAPS), complemented by scintillating tiles and fibres for precise timing measurements. The experiment produces about 100 Gbit/s of zero-suppressed data which are transported to a filter farm using a network of FPGAs and fast optical links. On the filter farm, tracks and three-particle vertices are reconstructed using highly parallel algorithms running on graphics processing units, leading to a reduction of the data to 100 Mbyte/s for mass storage and offline analysis. The paper introduces the system design and hardware implementation of the Mu3e data acquisition and filter farm.

physics.ins-det