SearcharxivSearch

arXiv subjects

Luyang Yu

Publications and source records attributed to Luyang Yu.

4 recordsLinked to original sources

REIN: Bridging the Gap between Reasoning and Reliability via Reflection and Abstention Alignment

Large reasoning models (LRMs) are prone to hallucination, which undermines their reliability and poses challenges for safe deployment. Hallucinations in LRMs arise from two distinct failure sources: reasoning hallucination, where flawed inference steps propagate to an incorrect conclusion, and knowledge hallucination, where the model lacks the requisite factual knowledge to answer the query. To address reasoning hallucination, we propose REIN, an alignment framework that trains LRMs to produce a structured reasoning sequence, $\texttt{ } $$\rightarrow$ $\texttt{ } $$\rightarrow$ $\texttt{ }$, enabling explicit self-reflection before committing to a final answer. To address knowledge hallucination, REIN introduces a reward mechanism that encourages explicit abstention (e.g., "I don't know") when none of the sampled reasoning chains yields a correct answer, allowing the model to refrain from unsupported predictions. Extensive evaluations on mathematical and commonsense reasoning benchmarks show that REIN consistently improves selective accuracy, reduces incorrect-but-self-endorsed responses, and maintains high coverage compared with competitive baselines. Notably, REIN achieves these gains within a single forward pass, without requiring process supervision, inference-time controllers, external search, or multi-round critiques. Experiments on multiple backbones show that REIN reduces the hallucination proxy by $58\sim72\%$ relative to the base models while maintaining $86\sim91\%$ average coverage, and improves selective accuracy on attempted questions by $6.6\sim14.2\%$.

cs.AI

Beam Test Results of High Q CBPM prototype for SXFEL

Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics has developed a high Q cavity beam position monitor (CBPM) that the resonant frequency is 4.7 GHz and relevant BPM electronics include dedicated RF front-end and home-made digital BPM (DBPM) also has been done. The cavity design, cold test, system architecture and the beam test with three adjacent pickups has been performed in Shanghai Deep ultraviolet free electron laser(SDUV-FEL) facility are included. The beam experiment results show that the physical design of our CBPM is consistent with the expectations basically and the beam position resolution can fulfill the resolution requirements for the SXFEL project if we optimize the beam conditions.

physics.acc-ph

Experimental Study using Touschek Lifetime as Machine Status Flag in SSRF

The stabilities of the beam and machine have almost the highest priority in a modern light source. Although a lot of machine parameters could be used to represent the beam quality, there lacks a single one that could indicate the global information for the machine operators and accelerator physicists, recently. A new parameter has been studied for the last few years as a beam quality flag in Shanghai Synchrotron Radiation Facility (SSRF). Calculations, simulations and detailed analysis of the real-time data from the storage ring had been made and interesting results had confirmed its feasibility.

physics.acc-ph

Design and test of SX-FEL cavity BPM

This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1{\mu}m, even 0.1{\mu}m. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117dB, and the shunt impedance is about 200{\Omega}@4.65GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90mV/mm when the source was 6dBm, and the accomplishable minimum voltage was about 200{\mu}V. The resolution of the CBPM was about 0.1{\mu}m from the linear fitting result based on the cold test.

physics.acc-ph