SearcharxivSearch

arXiv subjects

M Manceau

Publications and source records attributed to M Manceau.

2 recordsLinked to original sources

Near-to mid-IR spectral purity transfer with a tunable frequency comb: methanol frequency metrology over a record frequency span

We report the upgrade and operation of a frequency-comb-assisted high-resolution mid-infrared molecular spectrometer allowing us to combine high spectral purity, SI-traceability, wide tunability and high sensitivity. An optical frequency comb is used to transfer the spectral purity of a SI-traceable 1.54 $\mu$m metrology-grade frequency reference to a 10.3 $\mu$m quantum cascade laser (QCL). The near-infrared reference is operated at the French time/frequency metrology institute, calibrated there to primary frequency standards, and transferred to Laboratoire de Physique des Lasers via the REFIMEVE fiber network. The QCL exhibits a line width of $\delta\nu\sim 0.1$ Hz, a sub-$10^{-15}$ relative frequency stability from 0.1 to 10 s and its frequency is traceable to the SI with a total relative uncertainty better than $4\times10^{-14}$ after 1-s averaging time. We have developed the instrumentation allowing comb modes to be continuously tuned over 9 GHz resulting in a QCL of record spectral purity uninterruptedly tunable at the precision of the reference over an unprecedented span of $\Delta\nu$ = 1.4 GHz. We have used our apparatus to conduct sub-Doppler spectroscopy of methanol in a multi-pass cell, demonstrating state-of-art frequency uncertainties down to the few kilohertz level ($\sim10^{-10}$ in relative value). We have observed weak intensity resonances unreported so far, resolved subtle doublets never seen before and brought to light discrepancies with the HITRAN database. This demonstrates the potential of our apparatus for probing subtle internal molecular processes, building accurate spectroscopic models of polyatomic molecules of atmospheric or astrophysical interest, and carrying out precise spectroscopic tests of fundamental physics.

physics.atom-ph

Demonstration and frequency noise characterization of a 17 $\mu$m quantum cascade laser

We evaluate the spectral performance of a novel continuous-wave room-temperature distributed feedback quantum cascade laser operating at the long wavelength of 17 $\mu$m. By demonstrating broadband laser absorption spectroscopy of the $\nu$2 fundamental vibrational mode of N2O molecules, we have determined the spectral range and established the spectroscopic potential of this laser. We have characterized the frequency noise and measured the line width of this new device, uncovering a discrepancy with the current consensus on the theoretical modeling of quantum cascade lasers. Our results confirm the potential of such novel narrow-line-width sources for vibrational spectroscopy. Extending laser spectroscopy to longer wavelength is a fascinating prospect that paves the way for a wide range of opportunities from chemical detection, to frequency metrology as well as for exploring light-matter interaction with an extended variety of molecules, from ultra-cold diatomic species to increasingly complex molecular systems.

physics.atom-ph