Searcharxiv⌕ Search

arXiv subjects

M. Ö. Sahin

Publications and source records attributed to M. Ö. Sahin.

2 recordsLinked to original sources

Lepton and photon energy scale and resolution corrections based on the minimization of an analytical likelihood: IJazZ2.0

We present a novel method to determine lepton energy scale and resolution corrections by means of an analytical likelihood maximization applied to Drell--Yan \(Z \to \ell\ell\) events. The approach relies on an exact analytical treatment of the Gaussian energy smearing model, avoiding random-number-based convolution techniques. This formulation results in a fully differentiable likelihood enabling the use of automatic differentiation algorithms, and thus a substantial reduction in computational cost. The method, implemented in the \ijazz software, allows the simultaneous extraction of scale and resolution parameters across multiple lepton categories defined by detector or kinematic variables. We validate the technique using toy Monte Carlo studies and realistic Pythia-based simulations, demonstrating unbiased parameter recovery and accurate uncertainty estimates. Particular attention is given to categorizations involving lepton transverse momentum, for which a relative-\(p_T\) strategy is introduced to mitigate biases induced by category migration and kinematic correlations. The method is further adapted to photon-energy scale measurement in \(Z \to μ^+μ^-γ\) decays. Compared to conventional approaches, the analytical method improves numerical stability, robustness of the minimization, and computational performance, making it well suited for large-scale precision calibration tasks at the LHC.

hep-ex↗

The CMS Barrel Timing Layer: test beam confirmation of module timing performance

First of its kind, the barrel section of the MIP Timing Detector is a large area timing detector based on LYSO:Ce crystals and SiPMs which are required to operate in an unprecedentedly harsh radiation environment (up to an integrated fluence of $2\times10^{14}$ 1 MeV $n_{eq}/cm^2$). It is designed as a key element of the upgrade of the existing CMS detector to provide a time resolution for minimum ionizing particles in the range between 30-60 ps throughout the entire operation at the High Luminosity LHC. A thorough optimization of its components has led to the final detector module layout which exploits 25 $\rm μm$ cell size SiPMs and 3.75 mm thick crystals. This design achieved the target performance in a series of test beam campaigns. In this paper we present test beam results which demonstrate the desired performance of detector modules in terms of radiation tolerance, time resolution and response uniformity.

physics.ins-det↗