Searcharxiv⌕ Search

arXiv subjects

M. A. Castellanos-Beltran

Publications and source records attributed to M. A. Castellanos-Beltran.

12 recordsLinked to original sources

Coherence-limited digital control of a superconducting qubit using a Josephson pulse generator at 3 K

Compared to traditional semiconductor control electronics (TSCE) located at room temperature, cryogenic single flux quantum (SFQ) electronics can provide qubit measurement and control alternatives that address critical issues related to scalability of cryogenic quantum processors. Single-qubit control and readout have been demonstrated recently using SFQ circuits coupled to superconducting qubits. Experiments where the SFQ electronics are co-located with the qubit have suffered from excess decoherence and loss due to quasiparticle poisoning of the qubit. A previous experiment by our group showed that moving the control electronics to the 3 K stage of the dilution refrigerator avoided this source of decoherence in a high-coherence 3D transmon geometry. In this paper, we also generate the pulses at the 3 K stage but have optimized the qubit design and control lines for scalable 2D transmon devices. We directly compare the qubit lifetime $T_1$, coherence time $T_2^*$ and gate fidelity when the qubit is controlled by the Josephson pulse generator (JPG) circuit versus the TSCE setup. We find agreement to within the daily fluctuations for $T_1$ and $T_2^*$, and agreement to within 10% for randomized benchmarking. We also performed interleaved randomized benchmarking on individual JPG gates demonstrating an average error per gate of $0.46$% showing good agreement with what is expected based on the qubit coherence and higher-state leakage. These results are an order of magnitude improvement in gate fidelity over our previous work and demonstrate that a Josephson microwave source operated at 3 K is a promising component for scalable qubit control.

quant-ph↗

Measurable Improvement in Multi-Qubit Readout Using a Kinetic Inductance Traveling Wave Parametric Amplifier

Increasing the size and complexity of quantum information systems requires highly-multiplexed readout architectures, as well as amplifier chains operating near the quantum limit (QL) of added noise. While documented prior efforts in KITWPA integration in quantum systems are scarce, in this work we demonstrate integration of a KI-TWPA with a multiplexed-qubit device. To quantify the system noise improvement we perform an ac Stark shift calibration to precisely determine noise power levels on-chip (at each cavity's reference plane) and the total system gain. We then characterize the qubit state measurement fidelity and the corresponding signal-to-noise ratio (SNR). To conduct the most faithful measurement of the benefits offered by the KI-TWPA we perform these measurements for readout chains where the high electron mobility transistor (HEMT) amplifier is the first-stage amplifier (FSA) - with none of the external hardware required to operate the KI-TWPA - and with the KI-TWPA as the FSA. While some readout cavities fall outside the KI-TWPA bandwidth, for those inside the bandwidth we demonstrate a maximum improvement in the state measurement SNR by a factor of 1.45, and increase the fidelity from 96.2% to 97.8%. These measurements demonstrate a system noise below 5 quanta referenced on-chip and we bound the KI-TWPA excess noise to be below 4 quanta for the six cavities inside its bandwidth. These results show a promising path forward for realizing quantum-limited readout chains in large qubit systems using a single parametric amplifier.

quant-ph↗

Transmon qubit modeling and characterization for Dark Matter search

This study presents the design, simulation, and experimental characterization of a superconducting transmon qubit circuit prototype for potential applications in dark matter detection experiments. We describe a planar circuit design featuring two non-interacting transmon qubits, one with fixed frequency and the other flux tunable. Finite-element simulations were employed to extract key Hamiltonian parameters and optimize component geometries. The qubit was fabricated and then characterized at $20$ mK, allowing for a comparison between simulated and measured qubit parameters. Good agreement was found for transition frequencies and anharmonicities (within 1\% and 10\% respectively) while coupling strengths exhibited larger discrepancies (30\%). We discuss potential causes for measured coherence times falling below expectations ($T_1\sim\,$1-2 \textmu s) and propose strategies for future design improvements. Notably, we demonstrate the application of a hybrid 3D-2D simulation approach for energy participation ratio evaluation, yielding a more accurate estimation of dielectric losses. This work represents an important first step in developing planar Quantum Non-Demolition (QND) single-photon counters for dark matter searches, particularly for axion and dark photon detection schemes.

quant-ph↗

Coherent-State Storage and Retrieval Between Superconducting Cavities Using Parametric Frequency Conversion

In superconducting quantum information, machined aluminum superconducting cavities have proven to be a well-controlled, low-dissipation electromagnetic environment for quantum circuits such as qubits. They can possess large internal quality factors, $Q_{int}>10^8$, and present the possibility of storing quantum information for times far exceeding those of microfabricated circuits. However, in order to be useful as a storage element, these cavities require a fast "read/write" mechanism--- in other words, they require tunable coupling between other systems of interest such as other cavity modes and qubits, as well as any associated readout hardware. In this work, we demonstrate these qualities in a simple dual cavity architecture in which a low-Q "readout" mode is parametrically coupled to a high-Q "storage" mode, allowing us to store and retrieve classical information. Specifically, we employ a flux-driven Josephson junction-based coupling scheme to controllably swap coherent states between two cavities, demonstrating full, sequenced control over the coupling rates between modes.

quant-ph↗

Fabrication and characterization of large arrays of mesoscopic gold rings on large-aspect-ratio cantilevers

We have fabricated large arrays of mesoscopic metal rings on ultrasensitive cantilevers. The arrays are defined by electron beam lithography and contain up to $10^5$ rings. The rings have a circumference of 1 $μ$m, and are made of ultrapure (6N) Au that is deposited onto a silicon-on-insulator wafer without an adhesion layer. Subsequent processing of the SOI wafer results in each array being supported at the end of a free-standing cantilever. To accommodate the large arrays while maintaining a low spring constant, the cantilevers are nearly 1 mm in both lateral dimensions and 100 nm thick. The extreme aspect ratio of the cantilevers, the large array size, and the absence of a sticking layer are intended to enable measurements of the rings' average persistent current $\langle I \rangle$ in the presence of relatively small magnetic fields. We describe the motivation for these measurements, the fabrication of the devices, and the characterization of the cantilevers' mechanical properties. We also discuss the devices' expected performance in measurements of $\langle I \rangle$.

cond-mat.mes-hall↗

Measurement of the full distribution of the persistent current in normal-metal rings

We have measured the persistent current in individual normal metal rings over a wide range of magnetic fields. From this data, we extract the first six cumulants of the single-ring persistent current distribution. Our results are consistent with the theoretical prediction that this distribution should be nearly Gaussian (i.e., that these cumulants should be nearly zero) for diffusive metallic rings. This measurement highlights the particular sensitivity of persistent current to the mesoscopic fluctuations within a single coherent volume.

cond-mat.mes-hall↗

Quantum state tomography of an itinerant squeezed microwave field

We perform state tomography of an itinerant squeezed state of the microwave field prepared by a Josephson parametric amplifier (JPA). We use a second JPA as a pre-amplifier to improve the quantum efficiency of the field quadrature measurement (QM) from 2% to 36 +/- 4%. Without correcting for the detection inefficiency we observe a minimum quadrature variance which is 69 +/- 8% of the variance of the vacuum. We reconstruct the state's density matrix by a maximum likelihood method and infer that the squeezed state has a minimum variance less than 40% of the vacuum, with uncertainty mostly caused by calibration systematics.

quant-ph↗

Strongly quadrature-dependent noise in superconducting micro-resonators measured at the vacuum-noise limit

We measure frequency- and dissipation-quadrature noise in superconducting lithographed microwave resonators with sensitivity near the vacuum noise level using a Josephson parametric amplifier. At an excitation power of 100~nW, these resonators show significant frequency noise caused by two-level systems. No excess dissipation-quadrature noise (above the vacuum noise) is observed to our measurement sensitivity. These measurements demonstrate that the excess dissipation-quadrature noise is negligible compared to vacuum fluctuations, at typical readout powers used in micro-resonator applications. Our results have important implications for resonant readout of various devices such as detectors, qubits and nano-mechanical oscillators.

cond-mat.supr-con↗

Nanomechanical motion measured with precision beyond the standard quantum limit

Nanomechanical oscillators are at the heart of ultrasensitive detectors of force, mass and motion. As these detectors progress to even better sensitivity, they will encounter measurement limits imposed by the laws of quantum mechanics. For example, if the imprecision of a measurement of an oscillator's position is pushed below the standard quantum limit (SQL), quantum mechanics demands that the motion of the oscillator be perturbed by an amount larger than the SQL. Minimizing this quantum backaction noise and nonfundamental, or technical, noise requires an information efficient measurement. Here we integrate a microwave cavity optomechanical system and a nearly noiseless amplifier into an interferometer to achieve an imprecision below the SQL. As the microwave interferometer is naturally operated at cryogenic temperatures, the thermal motion of the oscillator is minimized, yielding an excellent force detector with a sensitivity of 0.51 aN/rt(Hz). In addition, the demonstrated efficient measurement is a critical step towards entangling mechanical oscillators with other quantum systems.

cond-mat.mes-hall↗

Bandwidth and dynamic range of a widely tunable Josephson parametric amplifier

The ability to manipulate quantum information encoded in microwave fields has led to a renewed interest in Josephson parametric amplifiers (JPAs). For these applications the ability of JPAs to amplify signals with the least amount of added noise is critical. Unfortunately JPAs are typically narrow band amplifiers with small dynamic range. It is therefore important to understand the bandwidth and dynamic range of any particular JPA in order to determine if it is appropriate for these applications. We recently introduced a new kind of JPA. Although it is still narrow band, the amplified band can be tuned over a full octave. We have shown that it has good noise performance and can squeeze the vacuum noise by 10 dB. Here we characterize other important parameters of this amplifier, specifically the signal-bandwidth, dynamic range and saturation power.

cond-mat.mes-hall↗

Amplification and squeezing of quantum noise with a tunable Josephson metamaterial

It has recently become possible to encode the quantum state of superconducting qubits and the position of nanomechanical oscillators into the states of microwave fields. However, to make an ideal measurement of the state of a qubit, or to detect the position of a mechanical oscillator with quantum-limited sensitivity requires an amplifier that adds no noise. If an amplifier adds less than half a quantum of noise, it can also squeeze the quantum noise of the electromagnetic vacuum. Highly squeezed states of the vacuum serve as an important quantum information resource. They can be used to generate entanglement or to realize back-action-evading measurements of position. Here we introduce a general purpose parametric device, which operates in a frequency band between 4 and 8 GHz. It is a subquantum-limited microwave amplifier, it amplifies quantum noise above the added noise of commercial amplifiers, and it squeezes quantum fluctuations by 10 dB.

cond-mat.mes-hall↗

A widely tunable parametric amplifier based on a SQUID array resonator

We create a Josephson parametric amplifier from a transmission line resonator whose inner conductor is made from a series SQUID array. By changing the magnetic flux through the SQUID loops, we are able to adjust the circuit's resonance frequency and, consenquently, the center of the amplified band, between 4 and 7.8 GHz. We observe that the amplifier has gains as large as 28 dB and infer that it adds less than twice the input vacuum noise.

cond-mat.supr-con↗