Searcharxiv⌕ Search

arXiv subjects

M. A. Leutenegger

Publications and source records attributed to M. A. Leutenegger.

At least 19 recordsLinked to original sources

High-resolution X-ray spectroscopy with XRISM/Resolve reveals super-Solar abundance ratios in Virgo/M87

The chemical composition of the intracluster medium (ICM) provides key insights into the enrichment history of galaxy clusters. However, high-resolution abundance measurements with X-ray microcalorimeters remain available for only a few systems. While most cool-core clusters exhibit near-Solar elemental abundance ratios relative to Fe, previous studies of the Virgo cluster suggested super-Solar ratios in its core. We investigate the chemical properties of the Virgo cluster core using XRISM/Resolve observations, focusing on precise measurements of Si, S, Ar, Ca, Cr, Fe, and Ni abundances. We aim to determine whether Virgo displays abundance patterns distinct from other nearby cool-core clusters and to explore the origin of any differences. We analysed XRISM/Resolve spectra in four regions of the Virgo core (center, east, northwest, and southwest) in the 1.7-11 keV band. Single-temperature, multi-temperature, and multi-abundance models were applied to characterize the thermal structure and derive elemental abundances. The resulting abundance ratios were compared between pointings, with previous studies of Virgo/M87, and with recent XRISM measurements of other clusters. All four pointings exhibit systematically super-Solar X/Fe ratios, although the northwest region shows values closer to Solar. Multi-abundance modeling of the eastern and southwestern regions reveals that cool, metal-rich gas uplifted by the AGN coexists with a hotter, more chemically homogeneous ambient ICM. The super-Solar ratios are robust against variations in bandpass and temperature structure. We interpret these enhanced ratios as reflecting the enrichment history of the old stellar population in M87 combined with a limited cold gas reservoir. The Virgo core exhibits spatially resolved chemical enrichment that differs from the abundance patterns observed in other cool-core clusters.

astro-ph.GA↗

Dynamics of AGN feedback in the X-ray bright East and Southwest arms of M87, mapped by XRISM

As the central galaxy in the nearest cluster, M87 provides the best spatial resolution for disentangling the complex interactions between AGN jets and the surrounding environment. We investigate the velocity structure of the multitemperature X-ray gas in M87, particularly in the eastern and southwestern arms associated with past AGN outbursts, using high-resolution spectroscopy from XRISM/Resolve. We analyze a mosaic of XRISM/Resolve observations covering the core of M87, fitting single- and multi-temperature models to spectra extracted from different regions and energy bands. We assess the line-of-sight velocities and velocity dispersions of the hotter ambient and cooler uplifted gas phases, and evaluate systematic uncertainties related to instrumental gain calibration. The hotter ICM phase, traced by Fe He-$α$ emission, shows velocity dispersions below $\sim100$ km/s, and no significant velocity shifts between the arms and a relaxed offset region, suggesting limited dynamical impact from older AGN lobes. In contrast, the cooler gas phase appears to exhibit larger line of sight velocity gradients up to several hundred km/s as well as a higher velocity dispersion than the ambient hot phase, although these conclusions remain tentative pending improvements in the robustness of the gain calibration at lower energies. The first microcalorimeter-resolved map of gas dynamics in M87 supports the uplift scenario for the X-ray arms, with the cooler gas in the east and southwest seemingly moving in opposite directions along the line of sight. The kinetic energy is a small fraction of the gravitational potential energy associated with the gas uplift, and XRISM further suggests that AGN-driven motions may be short-lived in the hot ambient ICM. These constraints provide important input towards shaping future models of AGN feedback.

astro-ph.GA↗

Frequently Used References For Atomic Data In X-ray Spectroscopy

Accurate atomic physics reference data are a crucial requirement for analysis and interpretation of observed spectra, even more so for observations with high spectral resolution. This document provides a curated list of atomic physics references frequently used for plasma diagnostics in X-ray spectroscopy, outside of comprehensive plasma models that typically come with their own underlying atomic databases. The list includes references to physical constants, laboratory benchmarks, transition energies, position and line shapes of neutral fluorescence lines, radiative branching ratios, and commonly used notation for prominent transitions. Quick-look tables for transition energies in H-, He-, and Li-like ions and line positions and shapes for fluorescence lines in neutrals. The main focus is on K-shell transitions. For the H- and He-like tables, we cite state-of-the art calculations that we consider currently the best available reference energies, which are considered high accuracy and thus typically used for energy scale calibration in laboratory measurements. Omissions in these tables are due to the lack of availability in the chosen references, and are not a statement about the relevance of these lines. Due to their complex and highly source-dependent line shape, the atomic data for neutrals is of lower accuracy than that for the highly charged ions, and the best reference data for these line shapes typically consist of empirical models derived from very high-resolution laboratory measurements. The table for neutrals provided here is consistent with the reference used for the energy gain scale calibration of XRISM/Resolve. This document is meant to serve as a resource to help find relevant references and conveniently formatted overview tables. When making use of the information found in these papers, credit should be given to their original authors by citing the appropriate references.

astro-ph.IM↗

Discovery of extraordinary X-ray emission from magnetospheric interaction in the unique binary stellar system $ε$ Lupi

We report detailed X-ray observations of the unique binary system $ε$ Lupi, the only known short-period binary consisting of two magnetic early-type stars. The components have comparably strong, but anti-aligned magnetic fields. The orbital and magnetic properties of the system imply that the magnetospheres overlap at all orbital phases, suggesting the possibility of variable inter-star magnetospheric interaction due to the non-negligible eccentricity of the orbit. To investigate this effect, we observed the X-ray emission from $ε$ Lupi both near and away from periastron passage, using the Neutron Star Interior Composition Explorer mission (NICER) X-ray Telescope. We find that the system produces excess X-ray emission at the periastron phase, suggesting the presence of variable inter-star magnetospheric interaction. We also discover that the enhancement at periastron is confined to a very narrow orbital phase range ($\approx 5\%$ of the orbital period), but the X-ray properties close to periastron phase are similar to those observed away from periastron. From these observations, we infer that the underlying cause is magnetic reconnection heating the stellar wind plasma, rather than shocks produced by wind-wind collision. Finally, by comparing the behavior of $ε$ Lupi with that observed for cooler magnetic binary systems, we propose that elevated X-ray flux at periastron phase is likely a general characteristic of interacting magnetospheres irrespective of the spectral types of the constituent stars.

astro-ph.HE↗

A new benchmark of soft X-ray transition energies of Ne, CO$_2$, and SF$_6$: paving a pathway towards ppm accuracy

A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of Ne, CO$_2$, and SF$_6$ gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s-np fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the CO$_2$ result agrees well with previous measurements, the SF$_6$ spectrum appears shifted by ~0.5 eV, about twice the uncertainty of the earlier results. Our result for Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1-10 meV, however, systematic contributions still limit the uncertainty to ~40-100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1-10 meV.

astro-ph.IM↗

High-Precision Determination of Oxygen-K$α$ Transition Energy Excludes Incongruent Motion of Interstellar Oxygen

We demonstrate a widely applicable technique to absolutely calibrate the energy scale of x-ray spectra with experimentally well-known and accurately calculable transitions of highly charged ions, allowing us to measure the K-shell Rydberg spectrum of molecular O$_2$ with 8 meV uncertainty. We reveal a systematic $\sim$450 meV shift from previous literature values, and settle an extraordinary discrepancy between astrophysical and laboratory measurements of neutral atomic oxygen, the latter being calibrated against the aforementioned O$_2$ literature values. Because of the widespread use of such, now deprecated, references, our method impacts on many branches of x-ray absorption spectroscopy. Moreover, it potentially reduces absolute uncertainties there to below the meV level.

physics.atom-ph↗

Radiography in high mass X-ray binaries -- Micro-structure of the stellar wind through variability of the column density

In high mass X-ray binaries (HMXBs), an accreting compact object orbits a high mass star which loses mass through a dense and inhomogeneous wind. Using the compact object as an X-ray backlight, the time variability of the absorbing column density in the wind can be exploited in order to shed light on the micro-structure of the wind and obtain unbiased stellar mass loss rates for high mass stars. We explore the impact of clumpiness on the variability of the column density with a simplified wind model. In particular, we focus on the standard deviation of the column density and the characteristic duration of enhanced absorption episodes, and compare them with analytical predictions based on the porosity length. We identified the favorable systems and orbital phases to determine the wind micro-structure. The coherence time scale of the column density is shown to be the self-crossing time of a clump in front of the compact object. We provide a recipe to get accurate measurements of the size and of the mass of the clumps, purely based on the observable time variability of the column density. The coherence time scale grants direct access to the size of the clumps while their mass can be deduced separately from the amplitude of the variability. If it is due to unaccreted passing-by clumps, the high column density variations in some HMXBs requires high mass clumps to reproduce the observed peak-to-peak amplitude and coherence time scales. These clump properties are hardly compatible with the ones derived from first principles. Alternatively, other components could contribute to the variability of the column density: larger orbital scale structures produced by a mechanism still to be identified, or a dense environment in the immediate vicinity of the accretor such as an accretion disk, an outflow or a spherical shell around the magnetosphere of the accreting neutron star.

astro-ph.HE↗

Simple, compact, high-resolution monochromatic x-ray source for characterization of x-ray calorimeter arrays

X-ray calorimeters routinely achieve very high spectral resolution, typically a few eV full width at half maximum (FWHM). Measurements of calorimeter line shapes are usually dominated by the natural linewidth of most laboratory calibration sources. This compounds the data acquisition time necessary to statistically sample the instrumental line broadening, and can add systematic uncertainty if the intrinsic line shape of the source is not well known. To address these issues, we have built a simple, compact monochromatic x-ray source using channel cut crystals. A commercial x-ray tube illuminates a pair of channel cut crystals which are aligned in a dispersive configuration to select the \kaone line of the x-ray tube anode material. The entire device, including x-ray tube, can be easily hand carried by one person and may be positioned manually or using a mechanical translation stage. The output monochromatic beam provides a collimated image of the anode spot with magnification of unity in the dispersion direction (typically 100-200 $μ$m for the x-ray tubes used here), and is unfocused in the cross-dispersion direction, so that the source image in the detector plane appears as a line. We measured output count rates as high as 10 count/s/pixel for the Hitomi Soft X-ray Spectrometer, which had 819 $μ$m square pixels. We implemented different monochromator designs for energies of 5.4 keV (one design) and 8.0 keV (two designs) which have effective theoretical FWHM energy resolution of 0.125, 0.197, and 0.086 eV, respectively; these are well-suited for optimal calibration measurements of state-of-the art x-ray calorimeters. We measured an upper limit for the energy resolution of our \crkaone monochromator of 0.7 eV FWHM at 5.4 keV, consistent with the theoretical prediction of 0.125 eV.

astro-ph.IM↗

High-resolution Charge Exchange Spectra with L-shell Nickel Show Striking Differences from Models

We present the first high-resolution laboratory spectra of X-ray emission following L-shell charge exchange between nickel ions and neutral H2 and He. We employ the commonly used charge exchange models found in XSPEC and SPEX, ACX and SPEX-CX, to simulate our experimental results. We show that significant differences between data and models exist in both line energies and strengths. In particular, we find that configuration mixing may play an important role in generating lines from core-excited states, and may be improperly treated in models. Our results indicate that if applied to astrophysical data, these models may lead to incorrect assumptions of the physical and chemical parameters of the region of interest.

astro-ph.HE↗

Feeding and feedback in the powerful radio galaxy 3C 120

We present the spectral analysis of a 200~ks observation of the broad-line radio galaxy 3C~120 performed with the high energy transmission grating (HETG) spectrometer on board the \emph{Chandra} X-ray Observatory. We find (i) a neutral absorption component intrinsic to the source with column density of $\text{log}N_H = 20.67\pm0.05$~cm$^{-2}$, (ii) no evidence for a warm absorber with an upper limit on the column density of just $\text{log}N_H < 19.7$~cm$^{-2}$ assuming the typical ionization parameter log$ξ$$\simeq$2.5~erg~s$^{-1}$~cm, the warm absorber may instead be replaced by (iii) a hot emitting gas with temperature $kT \simeq 0.7$~keV observed as soft X-ray emission from ionized Fe L-shell lines which may originate from a kpc scale shocked bubble inflated by the AGN wind or jet with a shock velocity of about 1,000~km~s$^{-1}$ determined by the emission line width, (iv) a neutral Fe K$α$ line and accompanying emission lines indicative of a Compton-thick cold reflector with low reflection fraction $R\simeq0.2$, suggesting a large opening angle of the torus, (v) a highly ionized Fe~XXV emission feature indicative of photoionized gas with ionization parameter log$ξ$$=$$3.75^{+0.27}_{-0.38}$~erg~s$^{-1}$~cm and a column density of $\text{log}N_H > 22$~cm$^{-2}$ localized within $\sim$2~pc from the X-ray source, and (vi) possible signatures for a highly ionized disk wind. Together with previous evidence for intense molecular line emission, these results indicate that 3C~120 is likely a late state merger undergoing strong AGN feedback.

astro-ph.HE↗

The complex circumnuclear environment of the broad-line radio galaxy 3C 390.3 revealed by Chandra HETG

We present the first high spectral resolution X-ray observation of the broad-line radio galaxy 3C 390.3 obtained with the high energy transmission grating (HETG) spectrometer on board the Chandra X-ray Observatory. The spectrum shows complex emission and absorption features in both the soft X-rays and Fe K band. We detect emission and absorption lines in the energy range between E = 700-1000 eV associated with ionized Fe L transitions (Fe XVII-XX). An emission line at the energy of E=6.4 keV consistent with the Fe Kαis also observed. Our best-fit model requires at least three different components: (i) a hot emission component likely associated with the hot interstellar medium in this elliptical galaxy with temperature kT=0.5+/-0.1 keV; (ii) a warm absorber with ionization parameter logξ=2.3+/-0.5 erg s^{-1} cm, column density logN_H=20.7+/-0.1 cm^{-2}, and outflow velocity of v_{out}<150 km s^{-1}; (iii) a lowly ionized reflection component in the Fe K band likely associated with the optical broad line region or the outer accretion disk. These evidences suggest the possibility that we are looking directly down the ionization cone of this active galaxy and that the central X-ray source only photoionizes along the unobscured cone. This is overall consistent with the angle-dependent unified picture of active galactic nuclei.

astro-ph.HE↗

Long term variability of Cygnus X-1: VII. Orbital variability of the focussed wind in Cyg X-1 / HDE 226868 system

Binary systems with an accreting compact object are a unique chance to investigate the strong, clumpy, line-driven winds of early type supergiants by using the compact object's X-rays to probe the wind structure. We analyze the two-component wind of HDE 226868, the O9.7Iab giant companion of the black hole Cyg X-1 using 4.77 Ms of RXTE observations of the system taken over the course of 16 years. Absorption changes strongly over the 5.6 d binary orbit, but also shows a large scatter at a given orbital phase, especially at superior conjunction. The orbital variability is most prominent when the black hole is in the hard X-ray state. Our data are poorer for the intermediate and soft state, but show signs for orbital variability of the absorption column in the intermediate state. We quantitatively compare the data in the hard state to a toy model of a focussed Castor-Abbott-Klein-wind: as it does not incorporate clumping, the model does not describe the observations well. A qualitative comparison to a simplified simulation of clumpy winds with spherical clumps shows good agreement in the distribution of the equivalent hydrogen column density for models with a porosity length on the order of the stellar radius at inferior conjunction; we conjecture that the deviations between data and model at superior conjunction could be either due to lack of a focussed wind component in the model or a more complicated clump structure.

astro-ph.HE↗

ASTRO-H White Paper - Stars -- Accretion, Shocks, Charge Exchanges and Magnetic Phenomena

X-ray emission from stars has origins as diverse as the stars themselves: accretion shocks, shocks generated in wind-wind collisions, or release of magnetic energy. Although the scenarios responsible for X-ray emission are thought to be known, the physical mechanisms operating are in many cases not yet fully understood. Full testing of many of these mechanisms requires high energy resolution, large effective area, and coverage of broad energy bands. The loss of the X-ray calorimeter spectrometer on board ASTRO-E2 was a huge blow to the field; it would have provided a large sample of high resolution spectra of stars with high signal-to-noise ratio. Now, with the advent of the ASTRO-H Soft X-ray Spectrometer and Hard X-ray Imager, we will be able to examine some of the hot topics in stellar astrophysics and solve outstanding mysteries.

astro-ph.HE↗

Accelerator experiments with soft protons and hyper-velocity dust particles: application to ongoing projects of future X-ray missions

We report on our activities, currently in progress, aimed at performing accelerator experiments with soft protons and hyper-velocity dust particles. They include tests of different types of X-ray detectors and related components (such as filters) and measurements of scattering of soft protons and hyper-velocity dust particles off X-ray mirror shells. These activities have been identified as a goal in the context of a number of ongoing space projects in order to assess the risk posed by environmental radiation and dust and qualify the adopted instrumentation with respect to possible damage or performance degradation. In this paper we focus on tests for the Silicon Drift Detectors (SDDs) used aboard the LOFT space mission. We use the Van de Graaff accelerators at the University of Tübingen and at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg, for soft proton and hyper-velocity dust tests respectively. We present the experimental set-up adopted to perform the tests, status of the activities and some very preliminary results achieved at present time.

astro-ph.IM↗

Solving the Puzzle of the Massive Star System Theta 2 Orionis A

The young O9.5 V spectroscopic binary Theta 2 Ori A shows moderately hard X-ray emission and relatively narrow X-ray lines, suggesting that it may be a Magnetically Confined Wind Shock (MCWS) source, similar to its more massive analogue Theta 1 Ori C. X-ray flares occurring near periastron led to the suggestion that the flares are produced via magnetic reconnection as magnetospheres on both components of the Theta 2 Ori A binary interact at closest approach. We use a series of high-resolution spectropolarimetric observations of Theta 2 Ori A to place an upper limit on the magnetic field strength of 135 G (95% credible region). Such a weak dipole field would not produce magnetic confinement, or a large magnetosphere. A sub-pixel analysis of the Chandra ACIS images of Theta 2 Ori A obtained during quiescence and flaring show that the hard, flaring X-rays are offset from the soft, quiescent emission by 0.4 arcsec. If the soft emission is associated with the A1/A2 spectroscopic binary, the offset and position angle of the hard, flaring source place it at the location of the intermediate-mass A3 companion, discovered via speckle interferometry. The spectropolarimetric and X-ray results taken together point to the A3 companion, not the massive A1/A2 binary, as the source of hard, flaring X-ray emission. We also discuss a similar analysis performed for the magnetic Bp star Sigma Ori E. We find a similar origin for its X-ray flaring.

astro-ph.SR↗

Measurement of anomalously strong emission from the 1s-9p transition in the spectrum of H-like phosphorus following charge exchange with molecular hydrogen

We have measured K-shell x-ray spectra of highly ionized argon and phosphorus following charge exchange with molecular hydrogen at low collision energy in an electron beam ion trap using an x-ray calorimeter array with $\sim$6 eV resolution. We find that the emission at the high-end of the Lyman series is greater by a factor of 2 for phosphorus than for argon, even though the measurement was performed concurrently and the atomic numbers are similar. This does not agree with current theoretical models and deviates from the trend observed in previous measurements.

physics.atom-ph↗

On the Importance of the Interclump Medium for Superionization: O VI Formation in the Wind of Zeta Pup

We have studied superionization and X-ray line formation in the spectra of Zeta Pup using our new stellar atmosphere code (XCMFGEN) that can be used to simultaneously analyze optical, UV, and X-ray observations. Here, we present results on the formation of the O VI ll1032, 1038 doublet. Our simulations, supported by simple theoretical calculations, show that clumped wind models that assume void in the interclump space cannot reproduce the observed O VI profiles. However, enough O VI can be produced if the voids are filled by a low density gas. The recombination of O VI is very efficient in the dense material but in the tenuous interclump region an observable amount of O VI can be maintained. We also find that different UV resonance lines are sensitive to different density regimes in Zeta Pup : C IV is almost exclusively formed within the densest regions, while the majority of O VI resides between clumps. N V is an intermediate case, with contributions from both the tenuous gas and clumps.

astro-ph↗

Resonance scattering in the X-ray emission line profiles of Zeta Puppis

We present XMM-Newton Reflection Grating Spectrometer observations of pairs of X-ray emission line profiles from the O star Zeta Pup that originate from the same He-like ion. The two profiles in each pair have different shapes and cannot both be consistently fit by models assuming the same wind parameters. We show that the differences in profile shape can be accounted for in a model including the effects of resonance scattering, which affects the resonance line in the pair but not the intercombination line. This implies that resonance scattering is also important in single resonance lines, where its effect is difficult to distinguish from a low effective continuum optical depth in the wind. Thus, resonance scattering may help reconcile X-ray line profile shapes with literature mass-loss rates.

astro-ph↗