SearcharxivSearch

arXiv subjects

M. Agostini

Publications and source records attributed to M. Agostini.

At least 19 recordsLinked to original sources

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{\beta\beta} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det

Non-dimensional confinement scaling in similar negative triangularity plasmas on the DIII-D and TCV tokamaks

Similarity experiments were performed on the DIII-D and TCV tokamaks to explore the scaling of energy confinement in negative triangularity plasmas using non-dimensional variables. Near up-down symmetric plasmas with large top-bottom averaged negative triangularity were created in a lower single null configuration, with the shape of the separatrix being closely matched between the two devices. The normalized energy confinement is found to weakly improve at increasing collisionality and, between the two devices, shows a machine size scaling behavior between Bohm and gyro-Bohm. Engineering scaling on a large DIII-D dataset is in agreement with the non-dimensional experiment.

physics.plasm-ph

Optical calibration systems of the Pacific Ocean Neutrino Experiment

This work presents the design and performance characterization of the optical calibration systems produced for the Pacific Ocean Neutrino Experiment (P-ONE), which target gain, energy and time calibration in the detector. These systems include novel light-pulse driver circuitry based on gallium nitride field-effect transistor technology and its application to directional and isotropic, self-monitoring optical calibration instruments. A total of 330 directional light pulsers and two isotropic, 17-inch calibration modules (P-CALs) were produced for the first P-ONE line. We present the designs and performance of both the directional and isotropic calibration devices and perform detailed optical characterizations of both full-production batches. In a wavelength range of $365 - 520\,$nm, our developed driver circuits achieve emission intensities up to $10^{11}\,$photons and pulse widths as small as $1.4\,$ns, respectively. Light-pulse drivers and self-monitoring electronics in the P-CAL were characterized using the same experimental setup, and the instrument's optical-isotropy design was optimized in combination with a dedicated GEANT4-based simulation framework. The optimized P-CAL achieves a simulated isotropy grade of $1.00 \pm 0.01$ across the entire $4\pi\,$solid angle range. These simulation investigations were explicitly confirmed by dedicated measurements in both air and water using two independent experimental setups, and we report the results. With this, a detailed performance estimate for deployed P-CAL modules in P-ONE was possible.

physics.ins-det

Long term study of sedimentation and biofouling at Cascadia Basin, the site of the Pacific Ocean Neutrino Experiment

STRings for Absorption Length in Water (STRAW)-a and b were pathfinder instruments deployed to characterize the anticipated site of the Pacific Ocean Neutrino Experiment (P-ONE), which is a future neutrino telescope that will be located in the North Pacific Ocean. Measurements of the evolution of the optical transmission efficiency from STRAW-a showed a decline over the detector's lifetime for the upward-facing modules. Video footage of the pathfinders strongly suggested this decline was caused by biofouling and sedimentation. We measure the effect of biofouling and sedimentation to be a decrease in the transparency of upward-facing optical surfaces over 5 years of operations. A majority of downward-facing optical surfaces, which will dominate P-ONE's sensitivity to astrophysical sources, showed no visible biofouling. Extrapolations motivated by biological growth models estimated that these losses started around 2.5 years after deployment, and suggest a reduction in transparency ranging from 35$\%$ of the original to complete obscuration for the upward-facing modules. Samples of biofouling were taken in order to identify the microbial diversity of these organisms and inform potential intervention strategies. Results of the microbial samples and a candidate anti-biofouling strategy that will be tested on upcoming P-ONE instruments are discussed.

hep-ex

Search for the in-situ production of $^{77}$Ge in the GERDA neutrinoless double-beta decay experiment

The beta decay of $^{77}$Ge and $^{77\mathrm{m}}$Ge, both produced by neutron capture on $^{76}$Ge, is a potential background for Germanium based neutrinoless double-beta decay search experiments such as GERDA or the LEGEND experiment. In this work we present a search for $^{77}$Ge decays in the full GERDA Phase II data set. A delayed coincidence method was employed to identify the decay of $^{77}$Ge via the isomeric state of $^{77}$As (9/2$^+$, 475 keV, ${T_{1/2} = 114}\,\mu $s, $^{77\mathrm{m}}$As). New digital signal processing methods were employed to select and analyze pile-up signals. No signal was observed, and an upper limit on the production rate of was set at $<0.216$ nuc/(kg$\cdot$yr) (90% CL). This corresponds to a total production rate of $^{77}$Ge and $^{77\mathrm{m}}$Ge of $<0.38$ nuc/(kg$\cdot$ yr) (90% CL), assuming equal production rates. A previous Monte Carlo study predicted a value for in-situ $^{77}$Ge and $^{77\mathrm{m}}$Ge production of (0.21$\pm$0.07) nuc/(kg$\cdot$yr), a prediction that is now further corroborated by our experimental limit. Moreover, tagging the isomeric state of $^{77\mathrm{m}}$As can be utilised to further suppress the $^{77}$Ge background. Considering the similar experimental configurations of LEGEND-1000 and GERDA, the cosmogenic background in LEGEND-1000 at LNGS is estimated to remain at a sub-dominant level.

nucl-ex

First Results on the Search for Lepton Number Violating Neutrinoless Double Beta Decay with the LEGEND-200 Experiment

The LEGEND collaboration is searching for neutrinoless double beta ($0\nu\beta\beta$) decay by operating high-purity germanium detectors enriched in $^{76}$Ge in a low-background liquid argon environment. Building on key technological innovations from GERDA and the MAJORANA DEMONSTRATOR, LEGEND-200 has performed a first $0\nu\beta\beta$ decay search based on 61.0 kg yr of data. Over half of this exposure comes from our highest performing detectors, including newly developed inverted-coaxial detectors, and is characterized by an estimated background level of $0.5^{+0.3}_{-0.2}$ cts/(keV kg yr) in the $0\nu\beta\beta$ decay signal region. A combined analysis of data from GERDA, the MAJORANA DEMONSTRATOR, and LEGEND-200, characterized by a 90% confidence level exclusion sensitivity of $2.8 \times 10^{26}$ yr on the half-life of $0\nu\beta\beta$ decay, reveals no evidence for a signal and sets a new observed lower limit at $T^{0\nu}_{1/2} > 1.9 \times 10^{26}$ yr (90% confidence level). Assuming the decay is mediated by Majorana neutrinos, this corresponds to an upper limit on the effective Majorana mass in the range $m_{\beta\beta} < 75-200$ meV, depending on the adopted nuclear matrix element.

hep-ex

Prototype acoustic positioning system for the Pacific Ocean Neutrino Experiment

We present the design and initial performance characterization of the prototype acoustic positioning system intended for the Pacific Ocean Neutrino Experiment. It comprises novel piezo-acoustic receivers with dedicated filtering- and amplification electronics installed in P-ONE instruments and is complemented by a commercial system comprised of cabled and autonomous acoustic pingers for sub-sea installation manufactured by Sonardyne Ltd. We performed an in-depth characterization of the acoustic receiver electronics and their acoustic sensitivity when integrated into P-ONE pressure housings. These show absolute sensitivities of up to $-125\,$dB re V$^2/\mu$Pa$^2$ in a frequency range of $10-40\,$kHz. We furthermore conducted a positioning measurement campaign in the ocean by deploying three autonomous acoustic pingers on the seafloor, as well as a cabled acoustic interrogator and a P-ONE prototype module deployed from a ship. Using a simple peak-finding detection algorithm, we observe high accuracy in the tracking of relative ranging times at approximately $230-280\,\mu$s at distances of up to $1600\,$m, which is sufficient for positioning detectors in a cubic-kilometer detector and which can be further improved with more involved detection algorithms. The tracking accuracy is further confirmed by independent ranging of the Sonardyne system and closely follows the ship's drift in the wind measured by GPS. The absolute positioning shows the same tracking accuracy with its absolute precision only limited by the large uncertainties of the deployed pinger positions on the seafloor.

physics.ins-det

Searches for new physics below twice the electron mass with GERDA

A search for full energy depositions from bosonic keV-scale dark matter candidates of masses between 65 keV and 1021 keV has been performed with data collected during Phase II of the GERmanium Detector Array (GERDA) experiment. Our analysis includes direct dark matter absorption as well as dark Compton scattering. With a total exposure of 105.5 kg yr, no evidence for a signal above the background has been observed. The resulting exclusion limits deduced with either Bayesian or Frequentist statistics are the most stringent direct constraints in the major part of the 140-1021 keV mass range. As an example, at a mass of 150 keV the dimensionless coupling of dark photons and axion-like particles to electrons has been constrained to $\alpha$'/$\alpha$ < 8.7x10$^{-24}$ and g$_{ae}$ < 3.3x10$^{-12}$ at 90% credible interval (CI), respectively. Additionally, a search for peak-like signals from beyond the Standard Model decays of nucleons and electrons is performed. We find for the inclusive decay of a single neutron in $^{76}$Ge a lower lifetime limit of $\tau_n$ > 1.5x10$^{24}$ yr and for a proton $\tau_p$ > 1.3x10$^{24}$ yr at 90% CI. For the electron decay e$^-\rightarrow\nu_e\gamma$ a lower limit of $\tau_e$ > 5.4x10$^{25}$ yr at 90% CI has been determined.

nucl-ex

An improved limit on the neutrinoless double-electron capture of $^{36}$Ar with GERDA

The GERmanium Detector Array (GERDA) experiment operated enriched high-purity germanium detectors in a liquid argon cryostat, which contains 0.33% of $^{36}$Ar, a candidate isotope for the two-neutrino double-electron capture (2$\nu$ECEC) and therefore for the neutrinoless double-electron capture (0$\nu$ECEC). If detected, this process would give evidence of lepton number violation and the Majorana nature of neutrinos. In the radiative 0$\nu$ECEC of $^{36}$Ar, a monochromatic photon is emitted with an energy of 429.88 keV, which may be detected by the GERDA germanium detectors. We searched for the $^{36}$Ar 0$\nu$ECEC with GERDA data, with a total live time of 4.34 yr (3.08 yr accumulated during GERDA Phase II and 1.26 yr during GERDA Phase I). No signal was found and a 90% C.L. lower limit on the half-life of this process was established T$_{1/2}$ > 1.5x10$^{22}$ yr

nucl-ex

Final Results of GERDA on the Two-Neutrino Double-$\beta$ Decay Half-Life of $^{76}$Ge

We present the measurement of the two-neutrino double-$\beta$ decay rate of $^{76}$Ge performed with the GERDA Phase II experiment. With a subset of the entire GERDA exposure, 11.8 kg$\cdot$yr, the half-life of the process has been determined: $T^{2\nu}_{1/2} = (2.022 \pm 0.018_{stat} \pm 0.038_{sys})\times10^{21}$ yr. This is the most precise determination of the $^{76}$Ge two-neutrino double-$\beta$ decay half-life and one of the most precise measurements of a double-$\beta$ decay process. The relevant nuclear matrix element can be extracted: $M^{2\nu}_{\text{eff}} = (0.101\pm0.001).$

nucl-ex

Search for tri-nucleon decays of $^{76}$Ge in GERDA

We search for tri-nucleon decays of $^{76}$Ge in the dataset from the GERmanium Detector Array (GERDA) experiment. Decays that populate excited levels of the daughter nucleus above the threshold for particle emission lead to disintegration and are not considered. The ppp-, ppn-, and pnn-decays lead to $^{73}$Cu, $^{73}$Zn, and $^{73}$Ga nuclei, respectively. These nuclei are unstable and eventually proceed by the beta decay of $^{73}$Ga to $^{73}$Ge (stable). We search for the $^{73}$Ga decay exploiting the fact that it dominantly populates the 66.7 keV $^{73m}$Ga state with half-life of 0.5 s. The nnn-decays of $^{76}$Ge that proceed via $^{73m}$Ge are also included in our analysis. We find no signal candidate and place a limit on the sum of the decay widths of the inclusive tri-nucleon decays that corresponds to a lower lifetime limit of 1.2x10$^{26}$ yr (90% credible interval). This result improves previous limits for tri-nucleon decays by one to three orders of magnitude.

nucl-ex

Probing Beyond the Standard Model Physics with Double-beta Decays

Nuclear double-beta decays are a unique probe to search for new physics beyond the Standard Model. Still-unknown particles, non-standard interactions, or the violation of fundamental symmetries would affect the decay kinematic, creating detectable and characteristic experimental signatures. In particular, the energy distribution of the electrons emitted in the decay gives an insight into the decay mechanism and has been studied in several isotopes and experiments. No deviations from the prediction of the Standard Model have been reported yet. However, several new experiments are underway or in preparation and will soon increase the sensitivity of these beyond the Standard Model physics searches, exploring uncharted parts of the parameter space. This review brings together phenomenological and experimental aspects related to new-physics searches in double-beta decay experiments, focusing on the testable models, the most-sensitive detection techniques, and the discovery opportunities of this field.

hep-ex

Lessons learned after three years of SPIDER operation and the first MITICA integrated tests

ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.

physics.plasm-ph

Liquid argon light collection and veto modeling in GERDA Phase II

The ability to detect liquid argon scintillation light from within a densely packed high-purity germanium detector array allowed the GERDA experiment to reach an exceptionally low background rate in the search for neutrinoless double beta decay of $^{76}$Ge. Proper modeling of the light propagation throughout the experimental setup, from any origin in the liquid argon volume to its eventual detection by the novel light read-out system, provides insight into the rejection capability and is a necessary ingredient to obtain robust background predictions. In this paper, we present a model of the GERDA liquid argon veto, as obtained by Monte Carlo simulations and constrained by calibration data, and highlight its application for background decomposition.

physics.ins-det

Search for exotic physics in double-$β$ decays with GERDA Phase II

A search for Beyond the Standard Model double-$β$ decay modes of $^{76}$Ge has been performed with data collected during the Phase II of the GERmanium Detector Array (GERDA) experiment, located at Laboratori Nazionali del Gran Sasso of INFN (Italy). Improved limits on the decays involving Majorons have been obtained, compared to previous experiments with $^{76}$Ge, with half-life values on the order of 10$^{23}$ yr. For the first time with $^{76}$Ge, limits on Lorentz invariance violation effects in double-$β$ decay have been obtained. The isotropic coefficient $\mathring{a}_\text{of}^{(3)}$, which embeds Lorentz violation in double-$β$ decay, has been constrained at the order of $10^{-6}$ GeV. We also set the first experimental limits on the search for light exotic fermions in double-$β$ decay, including sterile neutrinos.

nucl-ex

Pulse shape analysis in GERDA Phase II

The GERmanium Detector Array (GERDA) collaboration searched for neutrinoless double-$β$ decay in $^{76}$Ge using isotopically enriched high purity germanium detectors at the Laboratori Nazionali del Gran Sasso of INFN. After Phase I (2011-2013), the experiment benefited from several upgrades, including an additional active veto based on LAr instrumentation and a significant increase of mass by point-contact germanium detectors that improved the half-life sensitivity of Phase II (2015-2019) by an order of magnitude. At the core of the background mitigation strategy, the analysis of the time profile of individual pulses provides a powerful topological discrimination of signal-like and background-like events. Data from regular $^{228}$Th calibrations and physics data were both considered in the evaluation of the pulse shape discrimination performance. In this work, we describe the various methods applied to the data collected in GERDA Phase II corresponding to an exposure of 103.7 kg$\cdot$yr. These methods suppress the background by a factor of about 5 in the region of interest around Q$_{ββ}$ = 2039 keV, while preserving (81$\pm$3)% of the signal. In addition, an exhaustive list of parameters is provided which were used in the final data analysis.

physics.ins-det

Correlated and Integrated Directionality for sub-MeV solar neutrinos in Borexino

Liquid scintillator detectors play a central role in the detection of neutrinos from various sources. In particular, it is the only technique used so far for the precision spectroscopy of sub-MeV solar neutrinos, as demonstrated by the Borexino experiment at the Gran Sasso National Laboratory in Italy. The benefit of a high light yield, and thus a low energy threshold and a good energy resolution, comes at the cost of the directional information featured by water Cherenkov detectors, measuring $^8$B solar neutrinos above a few MeV. In this paper we provide the first directionality measurement of sub-MeV solar neutrinos which exploits the correlation between the first few detected photons in each event and the known position of the Sun for each event. This is also the first signature of directionality in neutrinos elastically scattering off electrons in a liquid scintillator target. This measurement exploits the sub-dominant, fast Cherenkov light emission that precedes the dominant yet slower scintillation light signal. Through this measurement, we have also been able to extract the rate of $^{7}$Be solar neutrinos in Borexino. The demonstration of directional sensitivity in a traditional liquid scintillator target paves the way for the possible exploitation of the Cherenkov light signal in future kton-scale experiments using liquid scintillator targets. Directionality is important for background suppression as well as the disentanglement of signals from various sources.

hep-ex

First Directional Measurement of sub-MeV Solar Neutrinos with Borexino

We report the measurement of sub-MeV solar neutrinos through the use of their associated Cherenkov radiation, performed with the Borexino detector at the Laboratori Nazionali del Gran Sasso. The measurement is achieved using a novel technique that correlates individual photon hits of events to the known position of the Sun. In an energy window between 0.54 MeV to 0.74 MeV, selected using the dominant scintillation light, we have measured 10887$^{+2386}_{-2103} (\mathrm{stat.})\pm 947 (\mathrm{syst.})$ ($68\%$ confidence interval) solar neutrinos out of 19904 total events. This corresponds to a $^{7}$Be neutrino interaction rate of 51.6$^{+13.9}_{-12.5}$ counts/(day$\cdot$ 100 ton), which is in agreement with the Standard Solar Model predictions and the previous spectroscopic results of Borexino. The no-neutrino hypothesis can be excluded with $>$5$σ$ confidence level. For the first time, we have demonstrated the possibility of utilizing the directional Cherenkov information for sub-MeV solar neutrinos, in a large-scale, high light yield liquid scintillator detector. This measurement provides an experimental proof of principle for future hybrid event reconstruction using both Cherenkov and scintillation signatures simultaneously.

hep-ex