SearcharxivSearch

arXiv subjects

M. Ahn

Publications and source records attributed to M. Ahn.

4 recordsLinked to original sources

Measurement of coherent elastic neutrino nucleus scattering on germanium by COHERENT

The COHERENT collaboration reports the most precise measurement of the coherent elastic neutrino-nucleus scattering cross section to date. This measurement was performed with COHERENT's germanium detector array, Ge-Mini, at the Spallation Neutron Source at Oak Ridge National Laboratory. A cumulative exposure of $4.68\times10^{22}$ protons on target yielded a total number of observed counts of $124^{+14}_{-12}$ and a flux-averaged cross section of $1.00 \pm 0.10 \mathrm{(statistical)} \pm 0.10 \mathrm{(systematic)}$ relative to the standard-model expectation of $5.9\times10^{-39} \mathrm{cm}^2$. The well-understood energy and timing distributions of the neutrino source allow for independent measurements of muon- and electron-neutrino scattering rates. This information is used to improve constraints on non-standard neutrino interactions mediated by heavy particles.

hep-ex

The COHERENT Experiment: 2026 Update

The COHERENT experiment measures neutrino-induced recoils from coherent elastic neutrino-nucleus scattering (CEvNS) with multiple nuclear targets at the Spallation Neutron Source (SNS) at the Oak Ridge National Laboratory (ORNL), USA. Several successful CEvNS measurements have been achieved in recent years with tens-of-kg detector masses, with a CsI scintillating crystal, a liquid argon single-phase detector, and high-purity germanium spectrometers. For the next phase, COHERENT aims at high-statistics detection of CEvNS events for precision tests of the standard model of particle physics, and to probe new physics beyond-the-standard model. Percent-level precision can be achieved by lowering thresholds, reducing backgrounds, and by scaling up the detector masses. It goes hand in hand with benchmarking the neutrino flux from the SNS. Further detectors will measure CEvNS in additional nuclei, including lighter target nuclei such as sodium and neon, to continue to test the expected neutron-number-squared dependence of the cross section. COHERENT can furthermore study charged-current and neutral-current inelastic neutrino-nucleus cross sections on various nuclei at neutrino energies below $\sim$50 MeV. Many of these cross sections have never been measured before, but are critical input for the interpretation of core-collapse supernova detection in large-scale neutrino experiments such as DUNE, Super-K, Hyper-K, and HALO.

hep-ex

Evidence of Coherent Elastic Neutrino-Nucleus Scattering with COHERENT's Germanium Array

We report the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on natural germanium, measured at the Spallation Neutron Source at Oak Ridge National Laboratory. The Ge-Mini detector of the COHERENT collaboration employs large-mass, low-noise, high-purity germanium spectrometers, enabling excellent energy resolution, and an analysis threshold of 1.5 keV electron-equivalent ionization energy. We observe a on-beam excess of 20.6 +7.1 -6.3 counts with a total exposure of 10.22 GWhkg and we reject the no-CEvNS hypothesis with 3.9 sigma significance. The result agrees with the predicted standard model of particle physics signal rate within 2 sigma.

hep-ex

The CDFII Time-Of-Flight Detector and Impact on Beauty Flavor Tagging

The new CDFII detector incorporates a Time-of-Flight detector (TOF), employing plastic scintillator bars and fine-mesh photomultipliers. Since August 2001 the TOF system has been fully instrumented and integrated into the CDFII data acquisition system. With a design goal of $100 ps$ resolution the TOF system will provide at least two standard deviations separation between $K^{\pm}$ and $π^{\pm}$ for momenta $p<1.6 GeV/c$, complementing low momentum particle identification by means of the specific ionization energy loss measured in the drift chamber. We describe the design of the TOF detector and discuss the current status of its calibration and initial performances. Finally we review the expected impact of the TOF detector in the flavor tagging of neutral $B_S$ meson.

hep-ex