SearcharxivSearch

arXiv subjects

M. Amano

Publications and source records attributed to M. Amano.

6 recordsLinked to original sources

Isochronous mass spectrometry at the RIKEN Rare-RI Ring facility

A dedicated isochronous storage ring, named the Rare-RI Ring, was constructed at the RI Beam Factory of RIKEN, aiming at precision mass measurements of nuclei located in uncharted territories of the nuclear chart. The Rare-RI Ring employs the isochronous mass spectrometry technique with the goal to achieve a relative mass precision of $10^{-6}$ within a measurement time of less than 1 ms. The performance of the facility was demonstrated through mass measurements of neutron-rich nuclei with well-known masses. Velocity or magnetic rigidity is measured for every particle prior to its injection into the ring, wherein its revolution time is accurately determined. The latter quantity is used to determine the mass of the particle, while the former one is needed for non-isochronicity corrections. Mass precisions on the order of $10^{-5}$ were achieved in the first commissioning, which demonstrates that Rare-RI Ring is a powerful tool for mass spectrometry of short-lived nuclei.

nucl-ex

Charge-changing cross sections for $^{42\textrm{--}51}$Ca and effect of charged-particle evaporation induced by neutron removal reaction

Charge-changing cross sections $σ_\mathrm{CC}$ for $^{42\textrm{--}51}$Ca on a carbon target at around 280~MeV/nucleon have been measured. The measured $σ_\mathrm{CC}$ values differ significantly from the previously developed calculations based on the Glauber model. However, through introduction of the charged-particle evaporation effect induced by the neutron-removal reaction in addition to the Glauber-model calculation, experimental $σ_\mathrm{CC}$ values on $^{12}$C at around 300~MeV/nucleon for nuclides from C to Fe isotopes are all reproduced with approximately 1\% accuracy. This proposed model systematically reproduces $σ_\mathrm{CC}$ data without phenomenological corrections, and can also explain experimental $σ_\mathrm{CC}$ values obtained in other energy regions.

nucl-ex

Development and operation of an electrostatic time-of-flight detector for the Rare RI storage Ring

An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil, potential grids, and a microchannel plate. Secondary electrons are released from the surface of the foil when a heavy ion hits it. The electrons are accelerated and deflected by 90$^\circ$ toward the microchannel plate by electrostatic potentials. A thin carbon foil and a thin aluminum-coated mylar foil were used as conversion foils. We obtained time resolutions of 69(1) ps and 43(1) ps (standard deviation) for a $^{84}$Kr beam at an energy of 170 MeV/u when using the carbon and the aluminum-coated mylar foils, respectively. A detection efficiency of approximately 90% was obtained for both foils. The E-MCP detector equipped with the carbon foil was installed inside the Rare-RI Ring to confirm particle circulation within a demonstration experiment on mass measurements of nuclei around $^{78}$Ge produced by in-flight fission of uranium beam at the RI Beam Factory in RIKEN. Periodic time signals from circulating ions were clearly observed. Revolution times for $^{78}$Ge, $^{77}$Ga, and $^{76}$Zn were obtained. The results confirmed successful circulation of the short-lived nuclei inside the Rare-RI Ring.

physics.ins-det

The second law of thermodynamics from concavity of energy eigenvalues

Quantum dynamics controlled by a time-dependent coupling constant are studied. It is proven that an energy eigenstate expectation value of work done by the system in a quench process cannot exceed the work in the corresponding quasi-static process, if and only if the energy eigenvalue is a concave function of the coupling constant. We propose this concavity of energy eigenvalues as a new universal criterion for quantum dynamical systems to satisfy the second law of thermodynamics. We argue simple universal conditions on quantum systems for the concavity, and show that every energy eigenvalue is indeed concave in some specific quantum systems. These results agree with the maximal work principle for adiabatic quench and quasi-static processes as an expression of the second law of thermodynamics. Our result gives a simple example of an integrable system satisfying an analogue to the strong eigenstate thermalization hypothesis (ETH) with respect to the principle of maximum work.

cond-mat.stat-mech

The second law of thermodynamics from concave energy in classical mechanics

A recently proposed quantum mechanical criterion `concavity of energy' for the second law of thermodynamics is studied also for classical particle systems confined in a bounded region by a potential with a time-dependent coupling constant. It is shown that the time average of work done by particles in a quench process cannot exceed that in the corresponding quasi-static process, if the energy is a concave function of the coupling constant. It is proven that the energy is indeed concave for a general confining potential with certain properties. This result implies that the system satisfies the principle of maximum work in the adiabatic environment as an expression of the second law of thermodynamics.

cond-mat.stat-mech

Swelling of doubly magic $^{48}$Ca core in Ca isotopes beyond $N=28$

Interaction cross sections for $^{42\textrm{-}51}$Ca on a carbon target at 280 MeV/nucleon have been measured for the first time. The neutron number dependence of derived root-mean-square matter radii shows a significant increase beyond the neutron magic number $N=28$. Furthermore, this enhancement of matter radii is much larger than that of the previously measured charge radii, indicating a novel growth in neutron skin thickness. A simple examination based on the Fermi-type distribution, and the Mean-Field calculations point out that this anomalous enhancement of the nuclear size beyond $N=28$ results from an enlargement of the core by a sudden increase in the surface diffuseness of the neutron density distribution, which implies the swelling of the bare $^{48}$Ca core in Ca isotopes beyond $N=28$.

nucl-ex