Searcharxiv⌕ Search

arXiv subjects

M. Antonello

Publications and source records attributed to M. Antonello.

42 records · Page 3Linked to original sources

A search for the analogue to Cherenkov radiation by high energy neutrinos at superluminal speeds in ICARUS

The OPERA collaboration has claimed evidence of superluminal ν{_μ} propagation between CERN and the LNGS. Cohen and Glashow argued that such neutrinos should lose energy by producing photons and e+e- pairs, through Z0 mediated processes analogous to Cherenkov radiation. In terms of the parameter delta=(v^2_nu-v^2_c)/v^2_c, the OPERA result implies delta = 5 x 10^-5. For this value of δa very significant deformation of the neutrino energy spectrum and an abundant production of photons and e+e- pairs should be observed at LNGS. We present an analysis based on the 2010 and part of the 2011 data sets from the ICARUS experiment, located at Gran Sasso National Laboratory and using the same neutrino beam from CERN. We find that the rates and deposited energy distributions of neutrino events in ICARUS agree with the expectations for an unperturbed spectrum of the CERN neutrino beam. Our results therefore refute a superluminal interpretation of the OPERA result according to the Cohen and Glashow prediction for a weak current analog to Cherenkov radiation. In particular no superluminal Cherenkov like e+e- pair or gamma emission event has been directly observed inside the fiducial volume of the "bubble chamber like" ICARUS TPC-LAr detector, setting the much stricter limit of delta < 2.5 10^-8 at the 90% confidence level, comparable with the one due to the observations from the SN1987A.

hep-ex↗

Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature

Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments.

physics.ins-det↗

Underground operation of the ICARUS T600 LAr-TPC: first results

Open questions are still present in fundamental Physics and Cosmology, like the nature of Dark Matter, the matter-antimatter asymmetry and the validity of the particle interaction Standard Model. Addressing these questions requires a new generation of massive particle detectors exploring the subatomic and astrophysical worlds. ICARUS T600 is the first large mass (760 ton) example of a novel detector generation able to combine the imaging capabilities of the old famous "bubble chamber" with an excellent energy measurement in huge electronic detectors. ICARUS T600 now operates at the Gran Sasso underground laboratory, studying cosmic rays, neutrino oscillation and proton decay. Physical potentialities of this novel telescope are presented through few examples of neutrino interactions reconstructed with unprecedented details. Detector design and early operation are also reported.

hep-ex↗

Study of Pion Production in ν_μCC Interactions on O16 Using Different MC Generators

In this report we present simulated event numbers, for various MC generators, for pion production in $ν_μ$ CC reactions on $\nucl{16}{O}$. For the simulation we used four different neutrino interaction generators: GENIE, FLUKA, NEUT, and NuWro, as proposed during the 45th Karpacz Winter School on neutrino interactions. First we give a brief outline of the theoretical models relevant to pion production. We then present results, in the form of tables showing the occupancy of primary and final state pion topologies, for all the generated samples. Finally we compare the results from the different generators and draw conclusions about the similarities and differences. For some of the generators we explore the effect of varying the axial mass parameter or the use of a different nuclear model.

hep-ph↗

Oxygen contamination in liquid Argon: combined effects on ionization electron charge and scintillation light

A dedicated test of the effects of Oxygen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. Two detectors have been used: the WArP 2.3 lt prototype and a small (0.7 lt) dedicated detector, coupled with a system for the injection of controlled amounts of gaseous Oxygen. Purpose of the test with the 0.7 lt detector is to detect the reduction of the long-lived component lifetime of the Argon scintillation light emission at increasing O2 concentration. Data from the WArP prototype are used for determining the behavior of both the ionization electron lifetime and the scintillation long-lived component lifetime during the O2-purification process activated in closed loop during the acquisition run. The electron lifetime measurements allow to infer the O2 content of the Argon and correlate it with the long-lived scintillation lifetime data. The effect of Oxygen contamination on the scintillation light has been thus measured over a wide range of O2 concentration, spanning from about 10^-3 ppm up to about 10 ppm. The rate constant of the light quenching process induced by Oxygen in LAr has been found to be k'(O2)=0.54+-0.03 micros^-1 ppm^-1.

nucl-ex↗

Effects of Nitrogen contamination in liquid Argon

A dedicated test of the effects of Nitrogen contamination in liquid Argon has been performed at the INFN-Gran Sasso Laboratory (LNGS, Italy) within the WArP R&D program. A detector has been designed and assembled for this specific task and connected to a system for the injection of controlled amounts of gaseous Nitrogen into the liquid Argon. Purpose of the test is to detect the reduction of the Ar scintillation light emission as a function of the amount of the Nitrogen contaminant injected in the Argon volume. A wide concentration range, spanning from about 10^-1 ppm up to about 10^3 ppm, has been explored. Measurements have been done with electrons in the energy range of minimum ionizing particles (gamma-conversion from radioactive sources). Source spectra at different Nitrogen contaminations are analyzed, showing sensitive reduction of the scintillation yield at increasing concentrations. The rate constant of the light quenching process induced by Nitrogen in liquid Ar has been found to be k(N2)=0.11 micros^-1 ppm^-1. Direct PMT signals acquisition at high time resolution by fast Waveform recording allowed to extract with high precision the main characteristics of the scintillation light emission in pure and contaminated LAr. In particular, the decreasing behavior in lifetime and relative amplitude of the slow component is found to be appreciable from O(1 ppm) of Nitrogen concentrations.

nucl-ex↗