Searcharxiv⌕ Search

arXiv subjects

M. B. Schneider

Publications and source records attributed to M. B. Schneider.

6 recordsLinked to original sources

Absolute Calibration of a Time-Resolved High Resolution X-ray Spectrometer for the National Ignition Facility (invited)

A high resolution, Diagnostic Instrument Manipulator (DIM)-based x-ray Bragg crystal spectrometer has been calibrated for and deployed at the National Ignition Facility (NIF) to diagnose plasma conditions in ignition capsules near stagnation times. The spectrometer has two conical crystals in the Hall geometry focusing rays from the Kr He$α$, Ly$α$, and He$β$ complexes onto a streak camera, with the physics objectives of measuring time-resolved electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. A third von Hámos crystal that time-integrates the Kr He$α$, He$β$ and intervening energy range provides in-situ calibration for the streak camera signals. The spectrometer has been absolutely calibrated using a microfocus x-ray source, an array of CCD and single-photon-counting detectors, and multiple K- and L-absorption edge filters at the Princeton Plasma Physics Laboratory (PPPL) x-ray laboratory. Measurements of the integrated reflectivity, energy range, and energy resolution for each crystal are discussed. These calibration data provide absolute x-ray signal levels for NIF measurements, enabling precise filter selection and comparisons to simulations.

physics.plasm-ph↗

Hot Spot Evolution Measured by High-Resolution X-Ray Spectroscopy at the National Ignition Facility

Evolution of the hot spot plasma conditions was measured using high-resolution x-ray spectroscopy at the National Ignition Facility (NIF). The capsules were filled with DD gas with trace levels of Kr, and had either a high-density-carbon (HDC) ablator or a tungsten (W)-doped HDC ablator. Time-resolved measurement of the Kr He$β$ spectra, absolutely calibrated by a simultaneous time-integrated measurement, allows inference of the electron density and temperature through observing Stark broadening and the relative intensities of dielectronic satellites. By matching the calculated hot spot emission using a collisional-radiative code to experimental observations, the hot spot size and areal density are determined. These advanced spectroscopy techniques further reveal the effect of W dopant in the ablator on the hot spot parameters for their improved implosion performance.

physics.plasm-ph↗

Resolving discrepancies in bang-time predictions for indirect-drive ICF experiments on the NIF: Insights from the Build-A-Hohlraum campaign

This study investigated discrepancies between measured and simulated x-ray drive in Inertial Confinement Fusion (ICF) hohlraums at the National Ignition Facility (NIF). Despite advances in radiation-hydrodynamic simulations, a consistent "drive deficit" remains. Experimentally measured ICF capsule bang-times are systematically 400-700 ps later than simulations predict. The Build-A-Hohlraum (BAH) campaign explored potential causes for this discrepancy by systematically varying hohlraum features, including laser entrance hole (LEH) windows, capsules, and gas fills. Overall, the agreement between simulated and experimental x-ray drive was found to be largely unaffected by these changes. The data allows us to exclude some hypotheses put forward to potentially explain the discrepancy. Errors in the local thermodynamic equilibrium (LTE) atomic modeling, errors in the modeling of LEH closure and errors due to a lack of plasma species mix physics in simulations are shown to be inconsistent with our measurements. Instead, the data supports the hypothesis that errors in NLTE emission modeling are a significant contributor to the discrepancy. X-ray emission in the 2 - 4 keV range is found to be approximately 30% lower than in simulations. This is accompanied by higher than predicted electron temperatures in the gold bubble region, pointing to errors in non-LTE modeling. Introducing an opacity multiplier of 0.87 on energy groups above 1.8 keV improves agreement with experimental data, reducing the bang-time discrepancy from 300 ps to 100 ps. These results underscore the need for refined NLTE opacity models to enhance the predictive power of hohlraum simulations.

physics.plasm-ph↗

A genetic algorithm approach to reconstructing spectral content from filtered x-ray diode array spectrometers

Filtered diode array spectrometers are routinely employed to infer the temporal evolution of spectral power from x-ray sources, but uniquely extracting spectral content from a finite set of broad, spectrally overlapping channel spectral sensitivities is decidedly nontrivial in these underdetermined systems. We present the use of genetic algorithms to reconstruct a probabilistic spectral intensity distribution and compare to the traditional approach most commonly found in literature. Unlike many of the previously published models, spectral reconstructions from this approach are neither limited by basis functional forms, nor do they require a priori spectral knowledge. While the original intent of such measurements was to diagnose the temporal evolution of spectral power from quasi-blackbody radiation sources, where the exact details of spectral content was not thought to be crucial, we demonstrate that this new technique can greatly enhance the utility of the diagnostic by providing more physical spectra and improved robustness to hardware configuration for even strongly non-Planckian distributions.

physics.comp-ph↗

The first cryogenic DT layered, beryllium capsule implosion at the National Ignition Facility

NIF experiments with Be capsules have followed a path of the highly successful "high-foot" CH capsules. Several keyhole and ConA targets preceeded a DT layered shot. In addition to backscatter subtraction, laser drive multipliers were needed to match observed X-ray drives. Those for the picket (0.95), trough (1.0) and second pulse (0.80) were determined by VISAR measurements. The time dependence of the Dante total x-ray flux and its fraction > 1.8 keV reflect the time dependence of the multipliers. A two step drive multiplier for the main pulse can match implosion times, but Dante measurements suggest the drive multiplier must increase late in time. With a single set of time dependent, multi-level multipliers the Dante data are well matched. These same third pulse drive multipliers also match the implosion times and Dante signals for two CH capsule DT. One discrepancy in the calculations is the X-ray flux in the picket. Calculations over-estimate the flux > 1.8 keV by a factor of ~100, while getting the total flux correctly. These harder X-rays cause an expansion of the Be/fuel interface of 2-3 km/s before the arrival of the first shock. VISAR measurements show only 0.2 to 0.3 km/s. The X-ray drive on the DT Be capsule was further degraded by a random decrease of 9% in the total picket flux. This small change caused the capsule fuel to change from an adiabat of 1.8 to 2.3 by mistiming of the first and second shocks. With this shock tuning and adjustments to the calculation, the first NIF Be capsule implosion achieved 29% of calculated yield, comparable to the CH DT capsules of 68% and 21%. Inclusion of a large M1 asymmetry in the DT ice layer and mixing from instability growth may help explain this final degradation. In summary when driven similarly the Be capsules performed like CH capsules. Performance degradation for both seems to be dominated by drive and capsule asymmetries.

physics.plasm-ph↗

Effect of Laser-Plasma Interactions on Inertial Fusion Hydrodynamics

The effects of laser-plasma interactions (LPI) on the dynamics of inertial confinement fusion hohlraums is investigated via a new approach that self-consistently couples reduced LPI models into radiation-hydrodynamics numerical codes. The interplay between hydrodynamics and LPI -- specifically stimulated Raman scatter (SRS) and crossed-beam energy transfer (CBET) -- mostly occurs via momentum and energy deposition into Langmuir and ion acoustic waves. This spatially redistributes energy coupling to the target, which affects the background plasma conditions and thus modifies laser propagation. This model shows reduced CBET, and significant laser energy depletion by Langmuir waves, which reduce the discrepancy between modeling and data from hohlraum experiments on wall x-ray emission and capsule implosion shape.

physics.plasm-ph↗