SearcharxivSearch

arXiv subjects

M. Barbisan

Publications and source records attributed to M. Barbisan.

17 recordsLinked to original sources

Laser diagnostics for negative ion source optimization: insights from SPIDER at the ITER Neutral Beam Test Facility

The ITER Heating Neutral Beams (HNBs) require large, high-energy H/D atom beams (285/330 A/m^2 extracted current density, and 1/0.87 MeV acceleration energy, respectively for H and D). To address the associated challenges, the SPIDER negative ion RF beam source at the Neutral Beam Test Facility (NBTF) in Padova (Italy) serves as a full-scale source prototype with a 100 kV triode accelerator, for design validation and performance verification. SPIDER is equipped with two advanced laser diagnostics to monitor key plasma parameters; Cavity Ring-Down Spectroscopy (CRDS) is used to measure H$^-$\slash D$^-$ ion densities, while Laser Absorption Spectroscopy (LAS) tracks caesium neutral density in the source. These measurements are essential for optimizing negative ion production and meeting ITER source targets. We present diagnostic upgrade details, recent experimental results, and correlations with other machine parameters. Since CRDS relies on a single 4.637-meter-long optical cavity, the longest used in such sources, it has demonstrated sensitivity to alignment. Based on recent experimental experience, structural improvements are being implemented to enhance both stability and measurement reliability. LAS has mainly been employed as a tool to monitor the caesium conditioning status of SPIDER. Additionally, due to a distributed measurement over four lines of sight, LAS has proven effective in monitoring the caesium distribution within the source. This work demonstrates the essential role of laser diagnostics in developing ITER-relevant plasma sources and informs ongoing efforts to improve measurement accuracy in challenging environments.

physics.plasm-ph

Cs evaporation in a negative ion source and Cs cleaning tests by plasma sputtering

The compact radio frequency negative ion source NIO1 (Negative Ion Optimization phase 1) has been designed, built and operated by Consorzio RFX and INFN-LNL in order to study and optimize the production and acceleration of H- ions in continuous operation. In 2020 Cs was evaporated in the source to increase the total extracted ion current. After an initial reduction of extracted electron to ion ratio and subsequently an increase of extracted negative ion current, the source performances progressively worsened, because of the excessive amount of Cs evaporated in the source; the extracted electron to ion ratio increased from below 1 to more than 10, while ion current density reduced from max. 67 A/m2 ion current to not more than 30 A/m2). The paper presents the experimental observations collected during Cs evaporation (reduction of plasma light, Cs emission and H$\beta$/H$\gamma$ ratio, etc.) that can help stopping the process before an excessive amount of Cs is introduced in the source. The paper also reports the cleaning techniques tested to remove the Cs excess by the action of hydrogen or argon plasmas; while argon was predictably more effective in surface sputtering, a 3 h Ar plasma treatment was not sufficient to recover from overcesiation.

physics.plasm-ph

First results from beam emission spectroscopy in SPIDER negative ion source

The SPIDER experiment, part of the Neutral Beam Test Facility (NBTF) at Consorzio RFX (Padua, Italy), is the prototype of the negative ion source for the ITER neutral beam injectors; the source is coupled to a 100 kV three-grid acceleration system. A Beam Emission Spectroscopy (BES) diagnostic was installed in SPIDER to study and optimize energy distribution, aiming, uniformity and divergence of the H-/D- beam extracted from the source. The diagnostic is based on the analysis of the Doppler shifted H{\alpha}/D{\alpha} light emitted in the interaction between the beam particles and the H2/D2 molecules of the background. In 2019 the BES diagnostic in SPIDER was installed and calibrated, and it allowed to characterize the first hydrogen beams extracted from the SPIDER source, in cesium free conditions. The number of active beamlets composing the beam was reduced from 1280 to 80, affecting the BES diagnostic capabilities. This paper presents the BES diagnostic setup and discusses the first collected results. Under limited extracted current density ($\sim$ 10 A/m^2) and ion energy ($\leq$35 keV), no significant vertical beam deflection caused by the magnetic filter field in the source was detected. In some cases the beamlets were observed to be elongated in horizontal direction; beamlet divergence values down to 20 mrad and 30 mrad e-folding were measured in vertical and horizontal direction, respectively; the intensity of the Doppler shifted radiation was found to be strongly correlated to the beam current and to the beam divergence. The progressive compensation of beamlet deflections (caused by electron suppression filter fields) with increasing voltage in the extraction gap was studied.

physics.plasm-ph

Lessons learned after three years of SPIDER operation and the first MITICA integrated tests

ITER envisages the use of two heating neutral beam injectors plus an optional one as part of the auxiliary heating and current drive system. The 16.5 MW expected neutral beam power per injector is several notches higher than worldwide existing facilities. A Neutral Beam Test Facility (NBTF) was established at Consorzio RFX, exploiting the synergy of two test beds, SPIDER and MITICA. SPIDER is dedicated to developing and characterizing large efficient negative ion sources at relevant parameters in ITER-like conditions: source and accelerator located in the same vacuum where the beam propagates, immunity to electromagnetic interferences of multiple radio-frequency (RF) antennas, avoidance of RF-induced discharges on the outside of the source. Three years of experiments on SPIDER have addressed to the necessary design modifications to enable full performances. The source is presently under a long shut-down phase to incorporate learnings from the experimental campaign. Parallelly, developments on MITICA, the full-scale prototype of the ITER NBI featuring a 1 MV accelerator and ion neutralization, are underway including manufacturing of in-vessel components, while power supplies and auxiliary plants are already under final testing and commissioning. Integration, commissioning and tests of the 1MV power supplies are essential for this first-of-kind system, unparalleled both in research and industry field. The integrated test to confirm 1MV output by combining invertor systems, DC generators and transmission lines extracted errors/accidents in some components. To realize a concrete system for ITER, solutions for the repair and the improvement of the system were developed. Hence, NBTF is emerging as a necessary facility, due to the large gap with existing injectors, effectively dedicated to identify issues and find solutions to enable successful ITER NBI operations in a time bound fashion.

physics.plasm-ph

Continuous pulse advances in the negative ion source NIO1

Consorzio RFX and INFN-LNL have designed, built and operated the compact radiofrequency negative ion source NIO1 (Negative Ion Optimization phase 1) with the aim of studying the production and acceleration of H- ions. In particular, NIO1 was designed to keep plasma generation and beam extraction continuously active for several hours. Since 2020 the production of negative ions at the plasma grid (the first grid of the acceleration system) has been enhanced by a Cs layer, deposited though active Cs evaporation in the source volume. For the negative ion sources applied to fusion neutral beam injectors, it is essential to keep the beam current and the fraction of co-extracted electrons stable for at least 1 h, against the consequences of Cs sputtering and redistribution operated by the plasma. The paper presents the latest results of the NIO1 source, in terms of caesiation process and beam performances during continuous (6{\div}7 h) plasma pulses. Due to the small dimensions of the NIO1 source (20 x (diam.)10 cm), the Cs density in the volume is high (10^15 \div 10^16 m^-3) and dominated by plasma-wall interaction. The maximum beam current density and minimum fraction of co-extracted electrons were respectively about 30 A/m^2 and 2. Similarly to what done in other negative ion sources, the plasma grid temperature in NIO1 was raised for the first time, up to 80 {\deg}C, although this led to a minimal improvement of the beam current and to an increase of the co-extracted electron current.

physics.plasm-ph

Development and first operation of a Cavity Ring Down Spectroscopy diagnostic in the negative ion source SPIDER

The Neutral Beam Injectors of the ITER experiment will rely on negative ion sources to produce 16.7 MW beams of H/D particles accelerated at 1 MeV. The prototype of these sources was built and is currently operated in the SPIDER experiment (Source for the Production of Ions o Deuterium Extracted from an RF plasma), part of the Neutral Beam Test Facility of Consorzio RFX, Padua. In SPIDER, the H-/D- ion source is coupled to a three grids 100 kV acceleration system. One of the main targets of the experimentation in SPIDER is to uniformly maximize the extracted current density; to achieve this it is important to study the density of negative ions available in proximity of the ion acceleration system. In SPIDER, line-integrated measurements of negative ion density are performed by a Cavity Ring Down Spectroscopy (CRDS) diagnostic. Its principle of operation is based on the absorption of the photons of a laser beam pulse by H-/D- photo-detachment; the absorption detection is enhanced by trapping the laser pulse in an optical cavity, containing the absorbing medium (i.e. negative ions). The paper presents and discusses the CRDS diagnostic setup in SPIDER, including the first measurements of negative ion density, correlated to the main source parameters.

physics.plasm-ph

Negative ion density in the ion source SPIDER in Cs free conditions

The SPIDER experiment, operated at the Neutral Beam Test Facility of Consorzio RFX, Padua, hosts the prototype of the H-/D- ion source for the ITER neutral beam injectors. The maximization of the ion current extracted from the source and the minimization of the amount of co-extracted electrons are among the most relevant targets to accomplish. The Cavity Ring-Down Spectroscopy diagnostic measures the negative ion density in the source close to the plasma grid (the plasma-facing grid of the ion acceleration system), so to identify the source operational parameters that maximize the amount of negative ions which can be extracted. In this study SPIDER was operated in hydrogen and deuterium in Cs-free conditions, therefore negative ions were mostly produced by reactions in the plasma volume. This work shows how the magnetic filter field and the bias currents, present in SPIDER to limit the amount of co-extracted electrons, affect the density of negative ions available for extraction. The results indicate that the magnetic filter field in front of the acceleration system should be set between about 1.6 mT, condition that maximizes the density of available negative ions, and about 3.2 mT, condition that minimizes the ratio of electron current to ion current. The negative ion density also resulted to be maximized when the plasma grid and its surrounding bias plate was positively biased against the source body with a total current in the range 0 A{\div}100 A. The paper shows also how much, in Cs-free conditions, the electric fields in the acceleration system can affect the density of negative ions in the source, close to the plasma grid apertures.

physics.plasm-ph

Electron Density and Temperature in NIO1 RF Source Operated in Oxygen and Argon

The NIO1 experiment, built and operated at Consorzio RFX, hosts an RF negative ion source, from which it is possible to produce a beam of maximum 130 mA in H- ions, accelerated up to 60 kV. For the preliminary tests of the extraction system the source has been operated in oxygen, whose high electronegativity allows to reach useful levels of extracted beam current. The efficiency of negative ions extraction is strongly influenced by the electron density and temperature close to the Plasma Grid, i.e. the grid of the acceleration system which faces the source. To support the tests, these parameters have been measured by means of the Optical Emission Spectroscopy diagnostic. This technique has involved the use of an oxygen-argon mixture to produce the plasma in the source. The intensities of specific Ar I and Ar II lines have been measured along lines of sight close to the Plasma Grid, and have been interpreted with the ADAS package to get the desired information. This work will describe the diagnostic hardware, the analysis method and the measured values of electron density and temperature, as function of the main source parameters (RF power, pressure, bias voltage and magnetic filter field). The main results show that not only electron density but also electron temperature increase with RF power; both decrease with increasing magnetic filter field. Variations of source pressure and plasma grid bias voltage appear to affect only electron temperature and electron density, respectively.

physics.plasm-ph

First Beam Characterization by Means of Emission Spectroscopy in the NIO1 Experiment

The NIO1 experiment hosts a flexible RF H- ion source, developed by INFN-LNL and Consorzio RFX to improve the present concepts for the production and acceleration of negative ions. The source is also used to benchmark the instrumentation dedicated to the ITER neutral beam test facility. Many diagnostics are installed in NIO1 to characterize the source and the extracted negative ion beam. Among them, Beam Emission Spectroscopy (BES) has been used in NIO1 to measure the divergence and the uniformity of the beam, together with the fraction of beam ions which was neutralized inside the acceleration system. The diagnostic method is based on the analysis of the Doppler shifted $H_α$ photons emitted by the fast beam particles and collected along a line of sight. The article presents the experimental setup and the analysis algorithms of the BES diagnostic, together with a discussion of the first measurements and of their correlation with the operational parameters.

physics.plasm-ph

Laser absorption spectroscopy studies to characterize Cs oven performances for the negative ion source SPIDER

The SPIDER H-/D- ion source is currently in operation in the Neutral Beam Test facility (NBTF) at Consorzio RFX (Padova, Italy) to prove the possibility of generating up to 40 A of negative ions, with a maximum extracted current density of 350 A/m2 (H)/285 A/m2 (D) and a fraction of co-extracted electrons not greater than 0.5 (H)/1 (D). These performances are required for the realization of the ITER Neutral Beam Injector (NBI), which should deliver 16.7 MW to the plasma by means of negative ions accelerated up to 1 MeV and neutralized before being injected into the ITER tokamak. In order to obtain such high extracted current densities and low co-extracted electron fractions it is necessary to lower the work function of the surface of the acceleration system grid facing the source; this will be accomplished by coating the surfaces with Cs, routinely evaporated by three ovens. The functionality of the ovens has been tested at the CAesium oven Test Stand (CATS), hosted at NBTF. The test stand is equipped with several diagnostics, among which a Laser Absorption Spectroscopy (LAS) diagnostic. Using a tunable laser diode, the LAS diagnostic gets the high resolution absorption spectrum of the Cs 852 nm D2 line along a line of sight to measure Cs density at ground state. The paper describes the test stand and the LAS diagnostic, together with the characterization of the ovens to be installed in SPIDER. The paper will also study the systematic density underestimation effect caused by Cs ground state depopulation, as a function of laser intensity and of Cs density, in the perspective of correcting the density evaluation.

physics.plasm-ph

First hydrogen operation of NIO1: characterization of the source plasma by means of an optical emission spectroscopy diagnostic

NIO1 is a compact and flexible radiofrequency H- ion source, developed by Consorzio RFX and INFN-LNL. Aim of the experimentation on NIO1 is the optimization of both the production of negative ions and their extraction and beam optics. In the initial phase of its commissioning, NIO1 was operated with nitrogen, but now the source is regularly operated also with hydrogen. To evaluate the source performances an optical emission spectroscopy diagnostic was installed. The system includes a low resolution spectrometer in the spectral range of 300-850 nm and a high resolution (50 pm) one, to study respectively the atomic and the molecular emissions in the visible range. The spectroscopic data have been interpreted also by means of a collisional-radiative model developed at IPP Garching. Besides the diagnostic hardware and the data analysis methods, the paper presents the first plasma measurements across a transition to the full H mode, in a hydrogen discharge. The characteristic signatures of this transition in the plasma parameters are described, in particular the sudden increase of the light emitted from the plasma above a certain power threshold.

physics.plasm-ph

Influence of the magnetic filter field topology on the beam divergence at the ELISE test facility

The ELISE test facility hosts a RF negative ion source, equipped with an extraction system which should deliver half the current foreseen for the ITER Neutral Beam Injector, keeping the ratio of co-extracted electrons to ions below 1. An important tool for the suppression of the co-extracted electrons is the magnetic filter field, produced by a current flowing in the plasma grid, the first grid of the 3 stage extraction system. To boost the source performances new concepts for the production of the magnetic filter field have been tested, combining the existing system with permanent magnets attached on the source walls. The topologies of these new magnetic configurations influence the beam particles trajectories in the extraction region, with consequences for the overall beam optics. These effects will be characterized in this article by studying the angular distribution of the beam particles, as measured by the Beam Emission Spectroscopy (BES) diagnostic. The behavior of the beam will be studied also through the measurements of the currents flowing on the grounded grid (the third grid) and on the grid holder box surrounding its exit. The main finding is that the broader component of the beam increases when the magnetic field is strengthened by permanent magnets, i.e. in the cases in which most of the co-extracted electrons are suppressed.

physics.plasm-ph

Beam characterization by means of emission spectroscopy in the ELISE test facility

The ELISE test facility at IPP Garching hosts a RF H-/D- ion source and an acceleration system. Its target is to demonstrate the performance foreseen for the ITER NBI system in terms of extracted current density (H/D), fraction of co-extracted electrons and pulse duration. The size of the ELISE extraction area is half that foreseen for the ITER NBI. This paper presents a detailed study of the ELISE beam divergence and uniformity. In particular, it was possible to describe the beam as the sum of two components at very different divergence: about 2° vs. 5°÷7°. As test cases, the beam properties have been measured as function of two source parameters. The first one is the current flowing through the grid facing the plasma, the Plasma Grid, in order to generate the magnetic filter field. The second one is the bias current flowing between the Plasma Grid and the source walls. Both the filter field and the bias current influence the fraction of co-extracted electrons, but also the properties of the plasma just in front of the extraction system and the beam properties. The divergence and the uniformity of the beam have been measured by a Beam Emission Spectroscopy (BES) diagnostic; the detailed analysis of the raw spectra collected by BES led to describing the beam with two components of different divergence. This concept has been supported by the information given by thermal imaging of the diagnostic calorimeter. Further support to the proposed beam model has been found in the behavior of the currents flowing in the acceleration system and beamline components; these currents are given by the most divergent (charged) particles of the beam.

physics.plasm-ph

Modeling and simulation of a beam emission spectroscopy diagnostic for the ITER prototype neutral beam injector

A test facility for the development of the Neutral Beam Injection system for ITER is under construction at Consorzio RFX. It will host two experiments: SPIDER, a 100 keV H-/D- ion RF source, and MITICA, a prototype of the full performance ITER injector (1 MV, 17 MW beam). A set of diagnostics will monitor the operation and allow to optimize the performance of the two prototypes. In particular, Beam Emission Spectroscopy will measure the uniformity and the divergence of the fast particles beam exiting the ion source and travelling through the beam line components. This type of measurement is based on the collection of the Hα/Dα emission resulting from the interaction of the energetic particles with the background gas. A numerical model has been developed to simulate the spectrum of the collected emissions in order to design this diagnostic and to study its performance. The paper describes the model at the base of the simulations and presents the modeled $H_α$ spectra in the case of MITICA experiment.

physics.plasm-ph

Design and preliminary operation of a laser absorption diagnostic for the SPIDER RF source

The ITER Heating Neutral Beam (HNB) injector is required to deliver 16.7 MW power into the plasma from a neutralised beam of H-/D- negative ions, produced by an RF source and accelerated up to 1 MeV. To enhance the H-/D- production, the surface of the acceleration system grid facing the source (the plasma grid) will be coated with Cs because of its low work function. Cs will be routinely evaporated in the source by means of specific ovens. Monitoring the evaporation rate and the distribution of Cs inside the source is fundamental to get the desired performances on the ITER HNB. In order to proper design the source of the ITER HNB and to identify the best operation practices for it, the prototype RF negative ion source SPIDER has been developed and built in the Neutral Beam Test Facility at Consorzio RFX. A Laser Absorption Spectroscopy diagnostic will be installed in SPIDER for a quantitative estimation of Cs density. By using a wavelength tunable laser, the diagnostic will measure the absorption spectrum of the 852 nm line along 4 lines of sight, parallel to the plasma grid surface and close to it. From the absorption spectra the line-integrated density of Cs at ground state will be measured. The design of this diagnostic for SPIDER is presented, with details of the layout and of the key components. A preliminary installation of the diagnostic on the test stand for Cs ovens is also described, together with its first experimental results; the effect of ground state depopulation on collected measurements is discussed and partially corrected.

physics.plasm-ph

Modeling and design of a BES diagnostic for the negative ion source NIO1

Consorzio RFX and INFN-LNL are building a flexible small ion source (NIO1) capable of producing about 130 mA of H- ions accelerated at 60 KeV. Aim of the experiment is to test and develop the instrumentation for SPIDER and MITICA, the prototypes respectively of the negative ion sources and of the whole neutral beam injectors which will operate in the ITER experiment. As SPIDER and MITICA, NIO1 will be monitored with Beam Emission Spectroscopy (BES), a non-invasive diagnostic based on the analysis of the spectrum of the $H_α$ emission produced by the interaction of the energetic ions with the background gas. Aim of BES is to monitor direction, divergence and uniformity of the ion beam. The precision of these measurements depends on a number of factors related to the physics of production and acceleration of the negative ions, to the geometry of the beam and to the collection optics. These elements were considered in a set of codes developed to identify the configuration of the diagnostic which minimizes the measurement errors. The model was already used to design the BES diagnostic for SPIDER and MITICA. The paper presents the model and describes its application to design the BES diagnostic in NIO1.

physics.plasm-ph

Characterization of Cs-free negative ion production in the ion source SPIDER by Cavity Ring-Down Spectroscopy

The Neutral beam Injectors of the ITER experiment will be based on negative ion sources for the generation of beams composed by 1 MeV H/D particles. The prototype of these sources is currently under testing in the SPIDER experiment, part of the Neutral Beam Test Facility of Consorzio RFX, Padua, Italy. Among the targets of the experimentation in SPIDER, it is of foremost importance to maximize the beam current density extracted from the source acceleration system. The SPIDER operating conditions can be optimized thanks to a Cavity Ring-down Spectroscopy diagnostic, which is able to give line-integrated measurements of negative ion density in proximity of the acceleration system apertures. Regarding the diagnostic technique, this work presents a phenomenon of drift in ring down time measurements, which develops in a time scale of few hours. This issue may significantly affect negative ion density measurements for plasma pulses of 1 h duration, as required by ITER. Causes and solutions are discussed. Regarding the source performance, this paper presents how negative ion density is influenced by the RF power used to sustain the plasma, and by the magnetic filter field present in SPIDER to limit the amount of co-extracted electrons. In this study, SPIDER was operated in hydrogen and deuterium, in Cs-free conditions.

physics.plasm-ph