Searcharxiv⌕ Search

arXiv subjects

M. Bhattacharya

Publications and source records attributed to M. Bhattacharya.

At least 73 records · Page 4Linked to original sources

Coherent control of an optical tweezer phonon laser

The creation and manipulation of coherence continues to capture the attention of scientists and engineers. The optical laser is a canonical example of a system that, in principle, exhibits complete coherence. Recent research has focused on the creation of coherent, laser-like states in other physical systems. The phonon laser is one example where it is possible to amplify self-sustained mechanical oscillations. A single mode phonon laser in a levitated optical tweezer has been demonstrated through appropriate balance of active feedback gain and damping. In this work, coherent control of the dynamics of an optical tweezer phonon laser is used to share coherence between its different modes of oscillation, creating a multimode phonon laser. The coupling of the modes is achieved by periodically rotating the asymmetric optical potential in the transverse focal plane of the trapping beam via trap laser polarization rotation. The presented theory and experiment demonstrate that coherence can be transferred across different modes of an optical tweezer phonon laser, and are a step toward using these systems for precision measurement and quantum information processing.

physics.optics↗

PT Symmetry, induced mechanical lasing and tunable force sensing in a coupled-mode optically levitated nanoparticle

We theoretically investigate PT symmetry, induced mechanical lasing and force sensing in an optically levitated nanoparticle with coupled oscillation modes. The coupling in the levitated system is created by the modulation of an asymmetric optical potential in the plane transverse to the beam trapping the nanoparticle. We show that such a coupling can lead to PT-symmetric mechanical behavior for experimentally realistic parameters. Further, by examining the phonon dynamics and the second-order coherence of the nanoparticle modes, we determine that induced mechanical lasing is also possible. Finally, we demonstrate that tunable ultra-sensitive force sensing can be engineered in the system. Our studies represent an advance in the fields of coherent manipulation of coupled degrees of freedom of levitated mechanical oscillators and their application for sensing.

quant-ph↗

Measurement of double-differential cross sections for mesonless charged-current muon neutrino interactions on argon with final-state protons using the MicroBooNE detector

Charged-current neutrino interactions with final states containing zero mesons and at least one proton are of high interest for current and future accelerator-based neutrino oscillation experiments. Using the Booster Neutrino Beam and the MicroBooNE detector at Fermi National Accelerator Laboratory, we have obtained the first double-differential cross section measurements of this channel for muon neutrino scattering on an argon target with a proton momentum threshold of 0.25 GeV/c. We also report a flux-averaged total cross section of $σ= (11.8 \pm 1.2) \times 10^{-38}$ cm$^2$ / Ar and several single-differential measurements which extend and improve upon previous results. Statistical and systematic uncertainties are quantified with a full treatment of correlations across 359 kinematic bins, including correlations between distributions describing different observables. The resulting data set provides the most detailed information obtained to date for testing models of mesonless neutrino-argon scattering.

hep-ex↗

Measurement of ambient radon progeny decay rates and energy spectra in liquid argon using the MicroBooNE detector

We report measurements of radon progeny in liquid argon within the MicroBooNE time projection chamber (LArTPC). The presence of specific radon daughters in MicroBooNE's 85 metric tons of active liquid argon bulk is probed with newly developed charge-based low-energy reconstruction tools and analysis techniques to detect correlated $^{214}$Bi-$^{214}$Po radioactive decays. Special datasets taken during periods of active radon doping enable new demonstrations of the calorimetric capabilities of single-phase neutrino LArTPCs for $β$ and $α$ particles with electron-equivalent energies ranging from 0.1 to 3.0 MeV. By applying $^{214}$Bi-$^{214}$Po detection algorithms to data recorded over a 46-day period, no statistically significant presence of radioactive $^{214}$Bi is detected, and a limit on the activity is placed at $<0.35$ mBq/kg at the 95% confidence level. This bulk $^{214}$Bi radiopurity limit -- the first ever reported for a liquid argon detector incorporating liquid-phase purification -- is then further discussed in relation to the targeted upper limit of 1 mBq/kg on bulk $^{222}$Rn activity for the DUNE neutrino detector.

hep-ex↗

Search for heavy neutral leptons in electron-positron and neutral-pion final states with the MicroBooNE detector

We present the first search for heavy neutral leptons (HNL) decaying into $νe^+e^-$ or $νπ^0$ final states in a liquid-argon time projection chamber using data collected with the MicroBooNE detector. The data were recorded synchronously with the NuMI neutrino beam from Fermilab's Main Injector corresponding to a total exposure of $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ in the mass ranges $10\le m_{\rm HNL}\le 150$ MeV for the $νe^+e^-$ channel and $150\le m_{\rm HNL}\le 245$ MeV for the $νπ^0$ channel, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$. These limits represent the most stringent constraints in the mass range $35<m_{\rm HNL}<175$ MeV and the first constraints from a direct search for $νπ^0$ decays.

hep-ex↗

Ring Bose-Einstein condensate in a cavity: Chirality Detection and Rotation Sensing

Recently, a method has been proposed to detect the rotation of a ring Bose-Einstein condensate, in situ, in real-time and with minimal destruction, using a cavity driven with optical fields carrying orbital angular momentum. This method is sensitive to the magnitude of the condensate winding number but not its sign. In the present work, we consider simulations of the rotation of the angular lattice formed by the optical fields and show that the resulting cavity transmission spectra are sensitive to the sign of the condensate winding number. We demonstrate the minimally destructive technique on persistent current rotational eigenstates, counter-rotating superpositions, and a soliton singly or in collision with a second soliton. Conversely, we also investigate the sensitivity of the ring condensate, given knowledge of its winding number, to the rotation of the optical lattice. This characterizes the effectiveness of the optomechanical configuration as a laboratory rotation sensor. Our results are important to studies of rotating ring condensates used in atomtronics, superfluid hydrodynamics, simulation of topological defects and cosmological theories, interferometry using matter-wave solitons, and optomechanical sensing.

cond-mat.quant-gas↗

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, $a_μ\equiv (g_μ- 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tildeω'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $ω_a$. From the ratio $ω_a / \tildeω'^{}_p$, together with precisely determined external parameters, we determine $a_μ= 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_μ\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_μ(\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.

hep-ex↗

First demonstration of $\mathcal{O}(1\,\text{ns})$ timing resolution in the MicroBooNE liquid argon time projection chamber

MicroBooNE is a neutrino experiment located in the Booster Neutrino Beamline (BNB) at Fermilab, which collected data from 2015 to 2021. MicroBooNE's liquid argon time projection chamber (LArTPC) is accompanied by a photon detection system consisting of 32 photomultiplier tubes used to measure the argon scintillation light and determine the timing of neutrino interactions. Analysis techniques combining light signals and reconstructed tracks are applied to achieve a neutrino interaction time resolution of $\mathcal{O}(1\,\text{ns})$. The result obtained allows MicroBooNE to access the ns neutrino pulse structure of the BNB for the first time. The timing resolution achieved will enable significant enhancement of cosmic background rejection for all neutrino analyses. Furthermore, the ns timing resolution opens new avenues to search for long-lived-particles such as heavy neutral leptons in MicroBooNE, as well as in future large LArTPC experiments, namely the SBN program and DUNE.

hep-ex↗

Cavity optomechanical detection of persistent currents and solitons in a bosonic ring condensate

We present numerical simulations of the cavity optomechanical detection of persistent currents and bright solitons in an atomic Bose-Einstein condensate confined in a ring trap. This work describes a novel technique that measures condensate rotation in situ, in real-time, and with minimal destruction, in contrast to currently used methods, all of which destroy the condensate completely. For weakly repulsive inter-atomic interactions, the analysis of persistent currents extends our previous few-mode treatment of the condensate [P. Kumar et al. Phys. Rev. Lett. 127, 113601 (2021)] to a stochastic Gross-Pitaevskii simulation. For weakly attractive atomic interactions, we present the first analysis of optomechanical detection of matter-wave soliton motion. We provide optical cavity transmission spectra containing signatures of the condensate rotation, sensitivity as a function of the system response frequency, and atomic density profiles quantifying the effect of the measurement backaction on the condensate. We treat the atoms at a mean-field level and the optical field classically, account for damping and noise in both degrees of freedom, and investigate the linear as well as nonlinear response of the configuration. Our results are consequential for the characterization of rotating matter waves in studies of atomtronics, superfluid hydrodynamics, and matter-wave soliton interferometry.

cond-mat.quant-gas↗

First measurement of quasi-elastic $Λ$ baryon production in muon anti-neutrino interactions in the MicroBooNE detector

We present the first measurement of the cross section of Cabibbo-suppressed $Λ$ baryon production, using data collected with the MicroBooNE detector when exposed to the neutrinos from the Main Injector beam at the Fermi National Accelerator Laboratory. The data analyzed correspond to $2.2 \times 10^{20}$ protons on target of neutrino mode running and $4.9 \times 10^{20}$ protons on target of anti-neutrino mode running. An automated selection is combined with hand scanning, with the former identifying five candidate $Λ$ production events when the signal was unblinded, consistent with the GENIE prediction of $5.3 \pm 1.1$ events. Several scanners were employed, selecting between three and five events, compared with a prediction from a blinded Monte Carlo simulation study of $3.7 \pm 1.0$ events. Restricting the phase space to only include $Λ$ baryons that decay above MicroBooNE's detection thresholds, we obtain a flux averaged cross section of $2.0^{+2.2}_{-1.7} \times 10^{-40}$ cm$^2/$Ar, where statistical and systematic uncertainties are combined.

hep-ex↗

Measurement of neutral current single $π^0$ production on argon with the MicroBooNE detector

We report the first measurement of $π^0$ production in neutral current (NC) interactions on argon with average neutrino energy of $\lesssim1$~GeV. We use data from the MicroBooNE detector's 85-tonne active volume liquid argon time projection chamber situated in Fermilab's Booster Neutrino Beam and exposed to $5.89\times10^{20}$ protons on target for this measurement. Measurements of NC $π^0$ events are reported for two exclusive event topologies without charged pions. Those include a topology with two photons from the decay of the $π^0$ and one proton and a topology with two photons and zero protons. Flux-averaged cross-sections for each exclusive topology and for their semi-inclusive combination are extracted (efficiency-correcting for two-plus proton final states), and the results are compared to predictions from the \textsc{genie}, \textsc{neut}, and \textsc{NuWro} neutrino event generators. We measure cross sections of $1.243\pm0.185$ (syst) $\pm0.076$ (stat), $0.444\pm0.098\pm0.047$, and $0.624\pm0.131\pm0.075$ $[10^{-38}\textrm{cm}^2/\textrm{Ar}]$ for the semi-inclusive NC$π^0$, exclusive NC$π^0$+1p, and exclusive NC$π^0$+0p processes, respectively.

hep-ex↗

Search for long-lived heavy neutral leptons and Higgs portal scalars decaying in the MicroBooNE detector

We present a search for long-lived Higgs portal scalars (HPS) and heavy neutral leptons (HNL) decaying in the MicroBooNE liquid-argon time projection chamber. The measurement is performed using data collected synchronously with the NuMI neutrino beam from Fermilab's Main Injector with a total exposure corresponding to $7.01 \times 10^{20}$ protons on target. We set upper limits at the $90\%$ confidence level on the mixing parameter $\lvert U_{μ4}\rvert^2$ ranging from $\lvert U_{μ4}\rvert^2<12.9\times 10^{-8}$ for Majorana HNLs with a mass of $m_{\rm HNL}=246$ MeV to $\lvert U_{μ4}\rvert^2<0.92 \times 10^{-8}$ for $m_{\rm HNL}=385$ MeV, assuming $\lvert U_{e 4}\rvert^2 = \lvert U_{τ4}\rvert^2 = 0$ and HNL decays into $μ^\pmπ^\mp$ pairs. These limits on $\lvert U_{μ4}\rvert^2$ represent an order of magnitude improvement in sensitivity compared to the previous MicroBooNE result. We also constrain the scalar-Higgs mixing angle $θ$ by searching for HPS decays into $μ^+μ^-$ final states, excluding a contour in the parameter space with lower bounds of $θ^2<31.3 \times 10^{-9}$ for $m_{\rm HPS}=212$ GeV and $θ^2<1.09 \times 10^{-9}$ for $m_{\rm HPS}=275$ GeV. These are the first constraints on the scalar-Higgs mixing angle $θ$ from a dedicated experimental search in this mass range.

hep-ex↗

First constraints on light sterile neutrino oscillations from combined appearance and disappearance searches with the MicroBooNE detector

We present a search for eV-scale sterile neutrino oscillations in the MicroBooNE liquid argon detector, simultaneously considering all possible appearance and disappearance effects within the $3+1$ active-to-sterile neutrino oscillation framework. We analyze the neutrino candidate events for the recent measurements of charged-current $ν_e$ and $ν_μ$ interactions in the MicroBooNE detector, using data corresponding to an exposure of 6.37$\times$10$^{20}$ protons on target from the Fermilab booster neutrino beam. We observe no evidence of light sterile neutrino oscillations and derive exclusion contours at the $95\%$ confidence level in the plane of the mass-squared splitting $Δm^2_{41}$ and the sterile neutrino mixing angles $θ_{μe}$ and $θ_{ee}$, excluding part of the parameter space allowed by experimental anomalies. Cancellation of $ν_e$ appearance and $ν_e$ disappearance effects due to the full $3+1$ treatment of the analysis leads to a degeneracy when determining the oscillation parameters, which is discussed in this paper and will be addressed by future analyses.

hep-ex↗

Observation of Radon Mitigation in MicroBooNE by a Liquid Argon Filtration System

The MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq $^{222}$Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 99.999% or 97%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the $^{222}$Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

physics.ins-det↗

Differential cross section measurement of charged current $ν_{e}$ interactions without final-state pions in MicroBooNE

In this letter we present the first measurements of an exclusive electron neutrino cross section with the MicroBooNE experiment using data from the Booster Neutrino Beamline at Fermilab. These measurements are made for a selection of charged-current electron neutrinos without final-state pions. Differential cross sections are extracted in energy and angle with respect to the beam for the electron and the leading proton. The differential cross section as a function of proton energy is measured using events with protons both above and below the visibility threshold. This is done by including a separate selection of electron neutrino events without reconstructed proton candidates in addition to those with proton candidates. Results are compared to the predictions from several modern generators, and we find the data agrees well with these models. The data shows best agreement, as quantified by $p$-value, with the generators that predict a lower overall cross section, such as GENIE v3 and NuWro.

hep-ex↗

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tildeω'^{}_p$, the denominator in the ratio $ω^{}_a$/$\tildeω'^{}_p$ that together with known fundamental constants yields $a^{}_μ$. The reported uncertainty on $\tildeω'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex↗

Direct measurement of atomic entanglement via cavity photon statistics

We propose an experimental scheme for the measurement of entanglement between two two-level atoms. Our scheme requires one of the two entangled atoms to interact with a cavity field dispersively, and we show that by measuring the zero time-delay second-order coherence function of the cavity field, one can measure the concurrence of an arbitrary Bell-like atomic two-qubit state. As our scheme requires only one of the atoms to interact with the measured cavity, the entanglement quantification becomes independent of the location of the other atom. Therefore, our scheme can have important implications for entanglement quantification in distributed quantum systems.

quant-ph↗

Highly magnetized white dwarfs: implications and current status

Over the last decade or so, we have been developing the possible existence of highly magnetized white dwarfs with analytical stellar structure models. While the primary aim was to explain the nature of the peculiar overluminous type Ia supernovae, later on, these magnetized stars were found to have even wider ranging implications including those for white dwarf pulsars, soft gamma-ray repeaters and anomalous X-ray pulsars, as well as gravitational radiation. In particular, we have explored in detail the mass-radius relations for these magnetized stars and showed that they can be significantly different from the Chandrasekhar predictions which essentially leads to a new super-Chandrasekhar mass-limit. Recently, using the stellar evolution code STARS, we have successfully modelled their formation and cooling evolution directly from the magnetized main sequence progenitor stars. Here we briefly discuss all these findings and conclude with their current status in the scientific community.

astro-ph.HE↗