Searcharxiv⌕ Search

arXiv subjects

M. Bhattarai

Publications and source records attributed to M. Bhattarai.

2 recordsLinked to original sources

Assessing Language Models for Scientific Applications: Inertial Confinement Fusion as a Use Case

Advancing language models for specialized scientific applications requires evaluations of scientific fluency, physical reasoning, and quantitative analyses. Using inertial confinement fusion (ICF) as a test case, we have developed an expert-curated benchmark of 250 questions spanning qualitative reasoning, numerical calculation, symbolic derivation, and equation formulation. Responses have been evaluated using deterministic numerical and symbolic checks together with language-model judges. We compared a variety of out-of-the-box closed-source and open-source large language models with Prospero, a model specialized through combined domain-adaptive pretraining and supervised fine-tuning for ICF. We also conducted initial retrieval-assisted evaluations. Prospero improved its aggregate score by 10.7 percentage points over its base model, with gains across all question types. Frontier models achieved the highest aggregate scores, but critical physics errors persisted, particularly in numerical calculations. We note that domain-specific performance can improve through specialization, but benchmark gains alone do not establish scientific reliability. Retrieval improved performance for a smaller model but yielded no statistically significant improvement for a frontier model. Two scientific stress tests further illustrate useful capabilities and the need for expert assessment of physical assumptions and model validity. Based on these findings, we recommend evaluating existing domain capabilities and retrieval benefits before committing to substantial additional specialization.

cs.AI↗

Proton therapy range uncertainty reduction using vendor-agnostic tissue characterization on a virtual photon-counting CT head scan

In this work, we proposed virtual imaging simulators as an alternative approach to experimental validation of beam range uncertainty in complex patient geometry using a computational model of a human head and a photon-counting CT scanner. We validate the accuracy of stopping power ratio (SPR) calculations using a conventional stoichiometric calibration approach and a prototype software, TissueXplorer. A validated CT simulator (DukeSim) was used to generate photon-counting CT projections of a computational head model, which were reconstructed with an open-source toolbox (ASTRA). The dose of 2 Gy was delivered through protons in a single fraction to target two different cases of nasal and brain tumors with a single lateral beam angle. Ground truth treatment plan was made directly on the computational head model using clinical treatment planning software (RayStation). This plan was then recalculated on the corresponding CT images for which SPR values were estimated using both the conventional method and the prototype software TissueXplorer. The mean percentage difference in estimating the stopping power ratio with TissueXplorer in all head tissues inside the scanned volume was 0.28%. Stopping power ratios obtained with this method showed smaller dose distribution differences from the ground truth plan than the conventional stoichiometric calibration method on the computational head model. Virtual imaging offers an alternative approach to validation of the SPR prediction from CT imaging, as well as its effect on the dose distribution and thus downstream clinical outcomes. According to this simulation study, software solutions that utilize spectral information, such as TissueXplorer, hold promise for more accurate prediction of the stopping power ratio than the conventional stoichiometric approach.

physics.med-ph↗