SearcharxivSearch

arXiv subjects

M. Blatnik

Publications and source records attributed to M. Blatnik.

17 recordsLinked to original sources

Detection of ultracold neutrons with powdered scintillator screens

Zinc sulfide (ZnS:Ag) scintillators coated with a thin 10B layer are widely used for ultracold neutron (UCN) detection, but their application is limited by long decay times and significant phosphorescence. We investigated two possible replacement scintillators: yttrium aluminum perovskite (YAP:Ce) and lutetium ttrium orthosilicate (LYSO:Ce). Both exhibit decay times on the order of 30-40 ns, which can help reduce dead time in high-count-rate experiments. YAP:Ce showed approximately 60% lower phosphorescence than ZnS:Ag after 2 days and detected about 20% more UCN. In contrast, LYSO:Ce exhibited higher phosphorescence and produced fewer UCN counts compared to both ZnS:Ag and YAP:Ce. While both tested scintillators are capable UCN detectors, YAP:Ce consistently outperformed LYSO:Ce across all measured performance metrics.

physics.ins-det

Scintillation characteristics of the EJ-299-02H scintillator

A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of the material known, the light yield of the scintillator can be calculated. The ability to make these scintillators deuterated, accompanied by its relatively thin dead layer, make it ideal for use in UCN experiment, where the light yield of decay electrons and alphas from neutron capture are critical for counting events.

physics.ins-det

YAP:Ce scintillator as an absolute ultracold neutron detector

The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $β$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probability for upscattering of ultracold neutrons, and its short decay time, which is important at high counting rates. Birks' coefficient of YAP:Ce was measured to be ($5.56^{+0.05}_{-0.30})\times 10^{-4}$ cm/MeV and light losses due to 120 nm of $^{10}$B-coating to be about 60%. The loss of light from YAP:Ce due to transmission through deuterated polystyrene scintillator was about 50%. The efficiency for counting neutrons that are captured on the $^{10}$B coating is (86.82 $\pm$ 2.61)%. Measurement with ultracold neutrons showed that YAP:Ce crystal counted 8% to 28% more UCNs compared to ZnS screen. This may be due to an uneven coating of $^{10}$B on the rough surface.

physics.ins-det

Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US

Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$τ$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $θ$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.

nucl-ex

Demonstration of Sub-micron UCN Position Resolution using Room-temperature CMOS Sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work [1, 2] that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully-connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

physics.ins-det

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

nucl-ex

Improved neutron lifetime measurement with UCN$τ$

We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $τ_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $β$-decay lifetime. Both techniques achieve consistent results and find a value $τ_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

nucl-ex

A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.

physics.ins-det

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.

nucl-ex

Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

nucl-ex

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

physics.ins-det

New result for the neutron $β$-asymmetry parameter $A_0$ from UCNA

The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $λ\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $λ\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.

nucl-ex

Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$

It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.

nucl-ex

Search for the Neutron Decay n$\rightarrow$ X+$γ$ where X is a dark matter particle

In a recent paper submitted to Physical Review Letters, Fornal and Grinstein have suggested that the discrepancy between two different methods of neutron lifetime measurements, the beam and bottle methods can be explained by a previously unobserved dark matter decay mode, n$\rightarrow$ X+$γ$ where X is a dark matter particle. We have performed a search for this decay mode over the allowed range of energies of the monoenergetic gamma ray for X to be a dark matter particle. We exclude the possibility of a sufficiently strong branch to explain the lifetime discrepancy with greater than 4 sigma confidence.

nucl-ex

Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments

We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.

physics.ins-det

Performance of a Quintuple-GEM Based RICH Detector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron ($π$, K, p) identification up to $\sim$~50 GeV/c. In this region Cerenkov Ring-Imaging is the most viable solution.\newline The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for PID reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ($\frac{dN_γ}{dx} \propto \sin^2{\left(θ_C \right)}$) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas ($CF_4$). The detector concept is a natural extension of the PHENIX HBD detector achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

physics.ins-det

A multilayer surface detector for ultracold neutrons

A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.

physics.ins-det