Searcharxiv⌕ Search

arXiv subjects

M. Bonesini

Publications and source records attributed to M. Bonesini.

At least 37 records · Page 2Linked to original sources

Improving the Time Resolution of Large-Area LaBr3:Ce Detectors with SiPM Array Readout

LaBr3:Ce crystals have good scintillation properties for X-ray spectroscopy. Initially, they were introduced for radiation imaging in medical physics with either a photomultiplier or SiPM readout, and they found extensive applications in homeland security and gamma-ray astronomy. We used 1 inch round LaBr3:Ce crystals to realize compact detectors with the SiPM array readout. The aim was a good energy resolution and a fast time response to detect low-energy X-rays around 100 keV. A natural application was found inside the FAMU experiment, at RIKEN RAL. Its aim is a precise measurement of the proton Zemach radius with impinging muons, to contribute to the solution to the so-called proton radius puzzle. Signals to be detected are characteristic X-rays around 130 KeV. A limit for this type of detector, as compared to the ones with a photomultiplier readout, is its poorer timing characteristics due to the large capacity of the SiPM arrays used. In particular, long signal falltimes are a problem in experiments such as FAMU, where a prompt background component must be separated from a delayed one (after 600 ns) in the signal X-rays to be detected. Dedicated studies were pursued to improve the timing characteristics of the used detectors, starting from hybrid ganging of SiPM cells; then developing a suitable zero pole circuit with a parallel ganging, where an increased overvoltage for the SiPM array was used to compensate for the signal decrease; and finally designing ad hoc electronics to split the 1 inch detector SiPM array into four quadrants, thus reducing the involved capacitances. The aim was to improve the detectors timing characteristics, especially falltime, while keeping a good FWHM energy resolution for low-energy X-ray detection.

physics.ins-det↗

Transverse Emittance Reduction in Muon Beams by Ionization Cooling

Accelerated muon beams have been considered for next-generation studies of high-energy lepton-antilepton collisions and neutrino oscillations. However, high-brightness muon beams have not yet been produced. The main challenge for muon acceleration and storage stems from the large phase-space volume occupied by the beam, derived from the muon production mechanism through the decay of pions from proton collisions. Ionization cooling is the technique proposed to decrease the muon beam phase-space volume. Here we demonstrate a clear signal of ionization cooling through the observation of transverse emittance reduction in beams that traverse lithium hydride or liquid hydrogen absorbers in the Muon Ionization Cooling Experiment (MICE). The measurement is well reproduced by the simulation of the experiment and the theoretical model. The results shown here represent a substantial advance towards the realization of muon-based facilities that could operate at the energy and intensity frontiers.

physics.acc-ph↗

Design and performance of the ENUBET monitored neutrino beam

The ENUBET project is aimed at designing and experimentally demonstrating the concept of monitored neutrino beams. These novel beams are enhanced by an instrumented decay tunnel, whose detectors reconstruct large-angle charged leptons produced in the tunnel and give a direct estimate of the neutrino flux at the source. These facilities are thus the ideal tool for high-precision neutrino cross-section measurements at the GeV scale because they offer superior control of beam systematics with respect to existing facilities. In this paper, we present the first end-to-end design of a monitored neutrino beam capable of monitoring lepton production at the single particle level. This goal is achieved by a new focusing system without magnetic horns, a 20 m normal-conducting transfer line for charge and momentum selection, and a 40 m tunnel instrumented with cost-effective particle detectors. Employing such a design, we show that percent precision in cross-section measurements can be achieved at the CERN SPS complex with existing neutrino detectors.

hep-ex↗

Experimental determination of the energy dependence of the rate of the muon transfer reaction from muonic hydrogen to oxygen for collision energies up to 0.1 eV

We report the first experimental determination of the collision-energy dependence of the muon transfer rate from the ground state of muonic hydrogen to oxygen at near-thermal energies. A sharp increase by nearly an order of magnitude in the energy range 0 - 70 meV was found that is not observed in other gases. The results set a reliable reference for quantum-mechanical calculations of low-energy processes with exotic atoms, and provide firm ground for the measurement of the hyperfine splitting in muonic hydrogen and the determination of the Zemach radius of the proton by the FAMU collaboration.

physics.atom-ph↗

Calibration of the ICARUS cryogenic photo-detection system at FNAL

The calibration of the ICARUS photo-detection system is based on a low power laser diode at 405 nm. Laser pulses arrive to one optical switch and then are sent to 36 UHV flanges, by 20 meters long optical patches. Light is then delivered to the ten PMTs connected to a single flange, by 7m long injection optical patches. Extensive tests of the used components and care in the design of the optical system have guaranteed to each PMT a sizeable calibration signal with minimal distortion, with respect to the original one. Gain equalization of PMTs has reached a 1 per cent resolution. In this procedure data from background photons were also used. The distribution of the PMTs signal arrival time has a distribution with a resolution less than 1 ns, thus allowing a good determination of the absolute event timing. The status of the laser calibration system with its possible upgrades will be reported.

physics.ins-det↗

Large area LaBr3:Ce crystals read by SiPM arrays with improved timing and temperature gain drift control

Compact X-rays detectors made of 1/2" or 1" :LaBr3:Ce crystals of cubic shape with SiPM array readout have been developed for the FAMU experiment at RIKEN-RAL. The aim is a precise measurement of the proton Zemach radius with incoming muons. Additional applications may be found in medical physics, such as PET, homeland security and gamma-ray astronomy. Due to the high photon yield of LaBr3:Ce it was possible to use a simple readout scheme based on CAEN V1730 digitizers. Detectors, using Hamamatsu S13361 or S14161 arrays, have good FWHM energy resolutions up to 3 % (8 %) at the Cs137 Co57) peak, comparing well with the best results obtained with a photomultiplier's readout. Detailed studies were performed to correct online the drift with temperature of SiPM gain and to reduce the risetime/falltime of detectors' signals, that increased going from 1/2" to 1" detectors, due to the larger capacity of the used SiPM arrays.

physics.ins-det↗

Online control of the gain drift with temperature of SiPM arrays used for the readout of LaB$_3$:Ce crystals

LaB$_3$:Ce crystals have been introduced for radiation imaging in medical physics, with photomultiplier or single SiPM readout. An R-D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm$^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution, good detector linearity and fast time response for low-energy X-rays. A natural application was found inside the FAMU project at RIKEN-RAL muon facility, that aims at a precise measure of the proton Zemach radius to solve the so-called "proton radius puzzle", triggered by the recent measure of the proton charge radius at PSI. The goal is the detection of characteristic X-rays around 130 keV. Other applications may be foreseen in medical physics, such as PET, and gamma-ray astronomy. A limiting factor is the gain drift of SiPM arrays with temperature, that give a deterioration of the detector's FWHM energy resolution. To solve this problem, a custom NIM module, based on CAEN A7585 digital power supply, was developed. Test results of the correction of gain drift with temperature for SiPM arrays from Advansid, Sensl, Hamamatsu will be presented. At the $^{137}$Cs peak, an energy resolution better than 3% was obtained for a typical LaBr$_3$:Ce crystal, using Hamamatsu S13461 arrays. This compares well with best available results obtained with PMTs.

physics.ins-det↗

Multiple Coulomb Scattering of muons in Lithium Hydride

Multiple Coulomb Scattering (MCS) is a well known phenomenon occurring when charged particles traverse materials. Measurements of muons traversing low $Z$ materials made in the MuScat experiment showed that theoretical models and simulation codes, such as GEANT4 (v7.0), over-estimated the scattering. The Muon Ionization Cooling Experiment (MICE) measured the cooling of a muon beam traversing a liquid hydrogen or lithium hydride (LiH) energy absorber as part of a programme to develop muon accelerator facilities, such as a Neutrino Factory or a Muon Collider. The energy loss and MCS that occur in the absorber material are competing effects that alter the performance of the cooling channel. Therefore measurements of MCS are required in order to validate the simulations used to predict the cooling performance in future accelerator facilities. We report measurements made in the MICE apparatus of MCS using a LiH absorber and muons within the momentum range 160 to 245 MeV/c. The measured RMS scattering width is about 9% smaller than that predicted by the approximate formula proposed by the Particle Data Group. Data at 172, 200 and 240 MeV/c are compared to the GEANT4 (v9.6) default scattering model. These measurements show agreement with this more recent GEANT4 (v9.6) version over the range of incident muon momenta.

hep-ex↗

A Muon Collider Facility for Physics Discovery

Muon colliders provide a unique route to deliver high energy collisions that enable discovery searches and precision measurements to extend our understanding of the fundamental laws of physics. The muon collider design aims to deliver physics reach at the highest energies with costs, power consumption and on a time scale that may prove favorable relative to other proposed facilities. In this context, a new international collaboration has formed to further extend the design concepts and performance studies of such a machine. This effort is focused on delivering the elements of a $\sim$10 TeV center of mass (CM) energy design to explore the physics energy frontier. The path to such a machine may pass through lower energy options. Currently a 3 TeV CM stage is considered. Other energy stages could also be explored, e.g. an s-channel Higgs Factory operating at 125 GeV CM. We describe the status of the R&D and design effort towards such a machine and lay out a plan to bring these concepts to maturity as a tool for the high energy physics community.

physics.acc-ph↗

The Short Baseline Neutrino Program at Fermilab

The current status of the Short Baseline Neutrino (SBN) project at Fermilab is reviewed. While the installation of SBND is still in progress, ICARUS has taken its first neutrino data on beam: using both the Booster Neutrino Beam (BNB) and the Neutrino at the Main Injector (NuMI) beam. MicroBooNE has presently completed its data taking and is producing the world's first high statistics results on $ν$-Ar interactions, in both inclusive and exclusive channels. In parallel, the unexpected MiniBooNE "low energy excess" is under investigation, to search for sterile neutrinos. The physics potential for sterile neutrino searches at SBN will be outlined, with emphasis on the Neutrino-4 experiment and the possible ICARUS verification of this claim.

hep-ex↗

Low-Energy Physics in Neutrino LArTPCs

In this white paper, we outline some of the scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) detectors. Key takeaways are summarized as follows. 1) LArTPCs have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. 2) Low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. 3) BSM signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of BSM scenarios accessible in LArTPC-based searches. 4) Neutrino interaction cross sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood. Improved theory and experimental measurements are needed. Pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for experimentally improving this understanding. 5) There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. 6) Novel ideas for future LArTPC technology that enhance low-energy capabilities should be explored. These include novel charge enhancement and readout systems, enhanced photon detection, low radioactivity argon, and xenon doping. 7) Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways.

physics.ins-det↗

Detection of low-energy X-rays with 1/2 and 1 inch LaBr3:Ce crystals read by SIPM arrays

LaBr3:Ce crystals, with photomultiplier or single SiPM readout (up to 3x3 mm$^2$) have been introduced for radiation imaging in medical physics. An R&D was pursued with 1/2" and 1" LaBr3:Ce crystals, from different producers, to realize compact large area detectors (up to some cm $^2$ area) with SiPM array readout, aiming at high light yields, good energy resolution,good detector linearity and fast time response for low-energy X-rays. The study was triggered by the FAMU experiment at the RIKEN-RAL muon facility, aiming at a precise measurement of the proton Zemach radius to solve the so-called "proton radius puzzle". The goal is the detection of characteristic X-rays around 130 KeV. Other applications may be foreseen for homeland security and $γ$-ray astronomy. Results were obtained with a direct readout based on a CAEN V1730 FADC, with no need for an amplification stage. At the Cs$^{137}$ peak, energy resolutions up to $\sim 3 \%$ were obtained, using a readout with Hamamatsu SiPM arrays. These results compare well with best available results obtained with a PMT readout.

physics.ins-det↗

Long-baseline neutrino oscillation physics potential of the DUNE experiment

The sensitivity of the Deep Underground Neutrino Experiment (DUNE) to neutrino oscillation is determined, based on a full simulation, reconstruction, and event selection of the far detector and a full simulation and parameterized analysis of the near detector. Detailed uncertainties due to the flux prediction, neutrino interaction model, and detector effects are included. DUNE will resolve the neutrino mass ordering to a precision of 5$σ$, for all $δ_{\mathrm{CP}}$ values, after 2 years of running with the nominal detector design and beam configuration. It has the potential to observe charge-parity violation in the neutrino sector to a precision of 3$σ$ (5$σ$) after an exposure of 5 (10) years, for 50\% of all $δ_{\mathrm{CP}}$ values. It will also make precise measurements of other parameters governing long-baseline neutrino oscillation, and after an exposure of 15 years will achieve a similar sensitivity to $\sin^{2} 2θ_{13}$ to current reactor experiments.

hep-ex↗

Performance of the MICE diagnostic system

Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams of a neutrino factory and for multi-TeV lepton-antilepton collisions at a muon collider. The international Muon Ionization Cooling Experiment (MICE) has demonstrated the principle of ionization cooling, the technique by which it is proposed to reduce the phase-space volume occupied by the muon beam at such facilities. This paper documents the performance of the detectors used in MICE to measure the muon-beam parameters, and the physical properties of the liquid hydrogen energy absorber during running.

physics.acc-ph↗

First results on ProtoDUNE-SP liquid argon time projection chamber performance from a beam test at the CERN Neutrino Platform

The ProtoDUNE-SP detector is a single-phase liquid argon time projection chamber with an active volume of $7.2\times 6.0\times 6.9$ m$^3$. It is installed at the CERN Neutrino Platform in a specially-constructed beam that delivers charged pions, kaons, protons, muons and electrons with momenta in the range 0.3 GeV$/c$ to 7 GeV/$c$. Beam line instrumentation provides accurate momentum measurements and particle identification. The ProtoDUNE-SP detector is a prototype for the first far detector module of the Deep Underground Neutrino Experiment, and it incorporates full-size components as designed for that module. This paper describes the beam line, the time projection chamber, the photon detectors, the cosmic-ray tagger, the signal processing and particle reconstruction. It presents the first results on ProtoDUNE-SP's performance, including noise and gain measurements, $dE/dx$ calibration for muons, protons, pions and electrons, drift electron lifetime measurements, and photon detector noise, signal sensitivity and time resolution measurements. The measured values meet or exceed the specifications for the DUNE far detector, in several cases by large margins. ProtoDUNE-SP's successful operation starting in 2018 and its production of large samples of high-quality data demonstrate the effectiveness of the single-phase far detector design.

physics.ins-det↗

Supernova Neutrino Burst Detection with the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE), a 40-kton underground liquid argon time projection chamber experiment, will be sensitive to the electron-neutrino flavor component of the burst of neutrinos expected from the next Galactic core-collapse supernova. Such an observation will bring unique insight into the astrophysics of core collapse as well as into the properties of neutrinos. The general capabilities of DUNE for neutrino detection in the relevant few- to few-tens-of-MeV neutrino energy range will be described. As an example, DUNE's ability to constrain the $ν_e$ spectral parameters of the neutrino burst will be considered.

hep-ex↗

Measurement of the muon transfer rate from muonic hydrogen to oxygen in the range 70-336 K

The first measurement of the temperature dependence of the muon transfer rate from muonic hydrogen to oxygen was performed by the FAMU collaboration in 2016. The results provide evidence that the transfer rate rises with the temperature in the range 104-300 K. This paper presents the results of the experiment done in 2018 to extend the measurements towards lower (70 K) and higher (336 K) temperatures. The 2018 results confirm the temperature dependence of the muon transfer rate observed in 2016 and sets firm ground for comparison with the theoretical predictions.

physics.atom-ph↗

Prospects for Beyond the Standard Model Physics Searches at the Deep Underground Neutrino Experiment

The Deep Underground Neutrino Experiment (DUNE) will be a powerful tool for a variety of physics topics. The high-intensity proton beams provide a large neutrino flux, sampled by a near detector system consisting of a combination of capable precision detectors, and by the massive far detector system located deep underground. This configuration sets up DUNE as a machine for discovery, as it enables opportunities not only to perform precision neutrino measurements that may uncover deviations from the present three-flavor mixing paradigm, but also to discover new particles and unveil new interactions and symmetries beyond those predicted in the Standard Model (SM). Of the many potential beyond the Standard Model (BSM) topics DUNE will probe, this paper presents a selection of studies quantifying DUNE's sensitivities to sterile neutrino mixing, heavy neutral leptons, non-standard interactions, CPT symmetry violation, Lorentz invariance violation, neutrino trident production, dark matter from both beam induced and cosmogenic sources, baryon number violation, and other new physics topics that complement those at high-energy colliders and significantly extend the present reach.

hep-ex↗