SearcharxivSearch

arXiv subjects

M. Bosman

Publications and source records attributed to M. Bosman.

7 recordsLinked to original sources

Tunable Ultra-Strong Magnon-Magnon Coupling Approaching the Deep-Strong Regime in a van der Waals Antiferromagnet

Antiferromagnetic (AFM) magnons in van der Waals (vdW) materials offer substantial potential for applications in magnonics and spintronics. In this study, we demonstrate ultra-strong magnon-magnon coupling in the GHz regime within a vdW AFM, achieving a maximum coupling rate of 0.91. Our investigation shows the tunability of coupling strength through temperature-dependent magnetic anisotropies. We compare coupling strength values derived from the gap size from the measured spectrum with those calculated directly through the coupling parameter and show that the gap size as a measure of coupling strength is limited for the ultra-strong coupling regime. Additionally, analytical calculations show the possibility to reach the deep-strong coupling regime by engineering the magnetic anisotropy. These findings highlight the potential of vdW AFMs as a model case to study magnetisation dynamics in low-symmetry magnetic materials.

cond-mat.mes-hall

The Cesium Source Calibration and Monitoring System of the ATLAS Tile Calorimeter: Design, Construction and Results

This article describes the design, construction and use of a calibration and monitoring system, based on movable 137Cs gamma-ray sources, for the ATLAS Tile Calorimeter (TileCal). The sources, propelled by a water-based liquid through tubes that traverse all the calorimeter's cells, produce signals that precisely characterise the response of each tile, thereby providing very granular and accurate data on the response of TileCal to particles. The system has been used to guide and control the quality of the optical instrumentation of all TileCal modules, to set and equalise the dynamic range of the response to physics data, and to set the energy scale of the readout system. In the ATLAS cavern, periodic measurements of the whole detector's response to 137Cs sources allow monitoring the uniformity and stability of all the calorimeter's cells as well as maintaining precise knowledge of its energy calibration. The design of the source hydraulic drive system's hardware and software, the data acquisition system and the data processing algorithms are described. Finally, the results of this two-decade program are shown.

physics.ins-det

Multimodal Plasmonics in Fused Colloidal Networks

Harnessing the optical properties of noble metals down to the nanometer-scale is a key step towards fast and low-dissipative information processing. At the 10-nm length scale, metal crystallinity and patterning as well as probing of surface plasmon (SP) properties must be controlled with a challenging high level of precision. Here, we demonstrate that ultimate lateral confinement and delocalization of SP modes are simultaneously achieved in extended self-assembled networks comprising linear chains of partially fused gold nanoparticles. The spectral and spatial distributions of the SP modes associated with the colloidal superstructures are evidenced by performing monochromated electron energy loss spectroscopy with a nanometer-sized electron probe. We prepare the metallic bead strings by electron beam-induced interparticle fusion of nanoparticle networks. The fused superstructures retain the native morphology and crystallinity but develop very low energy SP modes that are capable of supporting long range and spectrally tunable propagation in nanoscale waveguides.

physics.optics

A Layer Correlation technique for pion energy calibration at the 2004 ATLAS Combined Beam Test

A new method for calibrating the hadron response of a segmented calorimeter is developed and successfully applied to beam test data. It is based on a principal component analysis of energy deposits in the calorimeter layers, exploiting longitudinal shower development information to improve the measured energy resolution. Corrections for invisible hadronic energy and energy lost in dead material in front of and between the calorimeters of the ATLAS experiment were calculated with simulated Geant4 Monte Carlo events and used to reconstruct the energy of pions impinging on the calorimeters during the 2004 Barrel Combined Beam Test at the CERN H8 area. For pion beams with energies between 20 GeV and 180 GeV, the particle energy is reconstructed within 3% and the energy resolution is improved by between 11% and 25% compared to the resolution at the electromagnetic scale.

physics.ins-det

Tau trigger at the ATLAS experiment

Many theoretical models, like the Standard Model or SUSY at large tan(beta), predict Higgs bosons or new particles which decay more abundantly to final states including tau leptons than to other leptons. At the energy scale of the LHC, the identification of tau leptons, in particular in the hadronic decay mode, will be a challenging task due to an overwhelming QCD background which gives rise to jets of particles that can be hard to distinguish from hadronic tau decays. Equipped with excellent tracking and calorimetry, the ATLAS experiment has developed tau identification tools capable of working at the trigger level. This contribution presents tau trigger algorithms which exploit the main features of hadronic tau decays and describes the current tau trigger commissioning activities.

hep-ex

Charged Pion Energy Reconstruction in the ATLAS Barrel Calorimeter

The intrinsic performance of the ATLAS barrel and extended barrel calorimeters for the measurement of charged pions is presented. Pion energy scans (E = 20, 50, 200, 400 and 1000 GeV) at two pseudo-rapidity points ($η$ = 0.3 and 1.3) and pseudorapidity scans ($-0.2 < η< 1.8$) with pions of constant transverse energy ($E_T = 20$ and 50 GeV) are analysed. A simple approach, that accounts in first order for non-compensation and dead material effects, is used for the pion energy reconstruction. The intrinsic performances of the calorimeter are studied: resolution, linearity, effect of dead material, tails in the energy distribution. The effect of electronic noise, cell energy cuts and restricted cone size are investigated.

hep-ex