SearcharxivSearch

arXiv subjects

M. Boutemeur

Publications and source records attributed to M. Boutemeur.

4 recordsLinked to original sources

Contribution of high energy physics techniques to the medical imaging field

The purpose of this study was to show how advanced concepts of compact, lossless and "Time Of Flight" (TOF) capable electronics similar to those foreseen for the LHC and ILC experiments could be fairly and easily transferred to the medical imaging field through Positron Emission Tomography (PET). As a wish of explanation, the two overriding weaknesses of PET camera readout electronics, namely dead-time and timing resolution, were investigated analytically and with a Monte-Carlo simulator presently dedicated to this task. Results have shown there was room left for count rate enhancement through a huge decrease of the timing resolution well below the nanosecond. The novel electronics scheme suggested for PET in this paper has been partly inspired by the long experience led in High Energy Physics where the latter requirement is compulsory. Its structure entirely pipelined combined to a pixelation of the whole detector should allow dead-times to be suppressed, while the absence of devoted timing channel would remove the preponderant contributions to the timing resolution. To the common solution for timing would substitute an optimal filtering method witch clearly appears as a good candidate as timing resolution of a few tens of picoseconds may be achieved provided the shape of the signal is known and sufficient samples are available with enough accuracy. First investigations have yield encouraging results as a sampling frequency of 50 MHz with a 7 bits precision appears sufficient to ensure the 500ps coincidence timing resolution planed. At this point, there will be a baby step ahead to draw benefice from a TOF implementation to the design and the enormous noise variance enhancement that would come with.

physics.ins-det

Bose Einstein correlations of neutral pion pairs at LEP

With the OPAL detector at LEP we measured at energies around the Z0 peak the Bose-Einstein Correlations (BECs) of neutral pion pairs. We compare the results of this measurement with former results obtained at LEP for hadrons including those obtained from Fermi-Dirac Correlations (FDCs).

hep-ex

A Cosmic Ray Measurement Facility for ATLAS Muon Chambers

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.

physics.ins-det

Study of the $ηπ^o$ system in the mass range up to 1200 MeV

The reaction $π^-p \to ηπ^o n$ has been studied with GAMS-2000 spectrometer in the secondary 38 GeV/c $π^-$-beam of the IHEP U-70 accelerator. Partial wave analysis of the reaction has been performed in the $ηπ^o$ mass range up to 1200 MeV. The $a_0(980)$-meson is seen as a sharp peak in S-wave. The $t$-dependence of $a_0(980)$ production cross section has been studied. Dominant production of the $a_0(980)$ at a small transfer momentum $t$ confirms the hypothesis of Achasov and Shestakov about significant contribution of the $ρ_2$ exchange ($I^GJ^{PC}=1^+2^{--}$) in the mechanism of $a_0(980)$ meson production in $t$-channel of the reaction.

hep-ex