SearcharxivSearch

arXiv subjects

M. Bychkov

Publications and source records attributed to M. Bychkov.

15 recordsLinked to original sources

Revealing Color Forces with Transverse Polarized Electron Scattering

The Spin Asymmetries of the Nucleon Experiment (SANE) measured two double spin asymmetries using a polarized proton target and polarized electron beam at two beam energies, 4.7 GeV and 5.9 GeV. A large-acceptance open-configuration detector package identified scattered electrons at 40$^{\circ}$ and covered a wide range in Bjorken $x$ ($0.3 < x < 0.8$). Proportional to an average color Lorentz force, the twist-3 matrix element, $\tilde{d}_2^p$, was extracted from the measured asymmetries at $Q^2$ values ranging from 2.0 to 6.0 GeV$^2$. The data display the opposite sign compared to most quark models, including the lattice QCD result, and an apparently unexpected scale dependence. Furthermore when combined with the neutron data in the same $Q^2$ range the results suggest a flavor independent average color Lorentz force.

nucl-ex

PEN experiment: a precise test of lepton universality

With few open channels and uncomplicated theoretical description, charged pion decays are uniquely sensitive to certain standard model (SM) symmetries, the universality of weak fermion couplings, and to aspects of pion structure and chiral dynamics. We review the current knowledge of the pion electronic decay $π^+ \to e^+ ν_e(γ)$, or $π_{e2(γ)}$, and the resulting limits on non-SM processes. Focusing on the PEN experiment at the Paul Scherrer Institute (PSI), Switzerland, we examine the prospects for further improvement in the near term.

hep-ex

Proton Form Factor Ratio, $μ_p G_E^p/G_M^p$ from Double Spin Asymmetry

The ratio of the electric and magnetic form factor of the proton, $μ_p G_E^p/G_M^p$, has been measured for elastic electron-proton scattering with polarized beam and target up to four-momentum transfer squared, $Q^2=5.66$ (GeV/c)$^2$ using the double spin asymmetry for target spin orientation aligned nearly perpendicular to the beam momentum direction. This measurement of $μ_p G_E^p/G_M^p$ agrees with the $Q^2$ dependence of previous recoil polarization data and reconfirms the discrepancy at high $Q^2$ between the Rosenbluth and the polarization-transfer method with a different measurement technique and systematic uncertainties uncorrelated to those of the recoil-polarization measurements. The form factor ratio at $Q^2$=2.06 (GeV/c)$^2$ has been measured as $μ_p G_E^p/G_M^p = 0.720 \pm 0.176_{stat} \pm 0.039_{sys}$, which is in agreement with an earlier measurement with the polarized target technique at similar kinematics. The form factor ratio at $Q^2$=5.66 (GeV/c)$^2$ has been determined as $μ_p G_E^p/G_M^p=0.244\pm0.353_{stat}\pm0.013_{sys}$, which represents the highest $Q^2$ reach with the double spin asymmetry with polarized target to date.

nucl-ex

Design and Performance of the Spin Asymmetries of the Nucleon Experiment

The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.

physics.ins-det

PEN: a low energy test of lepton universality

Allowed charged $π$ meson decays are characterized by simple dynamics, few available decay channels, mainly into leptons, and extremely well controlled radiative and loop corrections. In that sense, pion decays represent a veritable triumph of the standard model (SM) of elementary particles and interactions. This relative theoretical simplicity makes charged pion decays a sensitive means for testing the underlying symmetries and the universality of weak fermion couplings, as well as for studying pion structure and chiral dynamics. Even after considerable recent improvements, experimental precision is lagging far behind that of the theoretical description for pion decays. We review the current state of experimental study of the pion electronic decay $π^+ \to e^+ν_e(γ)$, or $π_{e2(γ)}$, where the $(γ)$ indicates inclusion and explicit treatment of radiative decay events. We briefly review the limits on non-SM processes arising from the present level of experimental precision in $π_{e2(γ)}$ decays. Focusing on the PEN experiment at the Paul Scherrer Institute (PSI), Switzerland, we examine the prospects for further improvement in the near term.

hep-ex

New results in rare allowed muon and pion decays

Simple dynamics, few available decay channels, and highly controlled radiative and loop corrections, make pion and muon decays a sensitive means of exploring details of the underlying symmetries. We review the current status of the rare decays: pi+ -> e+ nu, pi+ -> e+ nu gamma, pi+ -> pi0 e+ nu, and mu+ -> e+ nu nu-bar gamma. For the latter we report new preliminary values for the branching ratio B(E_gamma >10 MeV, theta_(e-gamma) > 30deg) = 4.365 (9)_stat (42)_syst x 10^{-3}, and the decay parameter eta-bar = 0.006 (17)_stat (18)_syst, both in excellent agreement with standard model predictions. We review recent measurements, particularly by the PIBETA and PEN experiments, and near-term prospects for improvement. These and other similar precise low energy studies complement modern collider results materially.

nucl-ex

New studies of allowed pion and muon decays

Building on the rare pion and muon decay results of the PIBETA experiment, the PEN collaboration has undertaken a precise measurement of B_{πe2} = R^π_{e/μ}, the π^+ -> e^+ν(γ) decay branching ratio, at the Paul Scherrer Institute, to reduce the present 40\times experimental precision lag behind theory to ~ 6-7\times. Because of large helicity suppression, R^π_{e/μ} is uniquely sensitive to contributions from non-(V-A) physics, making this decay a particularly suitable subject of study. Even at current precision, the experimental value of B_{πe2} provides the most accurate test of lepton universality available. During runs in 2008-10, PEN has accumulated over 2\times 10^7 π_{e2} events; a comprehensive maximum-likelihood analysis is currently under way. The new data will also lead to improved precision of the earlier PIBETA results on radiative πand μdecays.

hep-ex

PEN: a sensitive search for non-(V-A) weak processes

A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Thanks to the large helicity suppression of $π_{e2}$ decay, the branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.

hep-ex

PEN experiment: a precise measurement of the pi+ -> e+ nu decay branching fraction

A new measurement of $B_{πe2}$, the $π^+ \to e^+ν(γ)$ decay branching ratio, is currently under way at the Paul Scherrer Institute. The present experimental result on $B_{πe2}$ constitutes the most accurate test of lepton universality available. The accuracy, however, still lags behind the theoretical precision by over an order of magnitude. Because of the large helicity suppression of the $π_{e2}$ decay, its branching ratio is susceptible to significant contributions from new physics, making this decay a particularly suitable subject of study.

hep-ex

New Precise Measurement of the Pion Weak Form Factors in the Pi+ -> e+ nu gamma Decay

We have measured the $π^+\to {\rm e}^+νγ$ branching ratio over a wide region of phase space, based on a total of 65,460 events acquired using the PIBETA detector. Minimum-$χ^2$ fits to the measured $(E_{e^+},E_γ)$ energy distributions result in the weak form factor value of $F_A=0.0119(1)$ with a fixed value of $F_V=0.0259$. An unconstrained fit yields $F_V=0.0258(17)$ and $F_A=0.0117(17)$. In addition, we have measured $a=0.10(6)$ for the dependence of $F_V$ on $q^2$, the ${\rm e}^{+}ν$ pair invariant mass squared, parametrized as $F_V(q^2)=F_V(0)(1+a\cdot q^2)$. The branching ratio for the kinematic region $E_γ> 10 $MeV and $θ_{{\rm e^+}γ} > 40^\circ $ is measured to be $B^{\rm exp}=73.86(54) \times 10^{-8}$. Earlier deviations we reported in the high-$E_γ$/low-$E_{{\rm e}^+}$ kinematic region are resolved, and we find full compatibility with CVC and standard $V$$-$$A$ calculations without a tensor term. We also derive new values for the pion polarizability, $α_E = \rm 2.78(10) \times 10^{-4} fm^3$, and neutral pion lifetime, $τ_{π0} = (8.5 \pm 1.1) \times 10^{-17} $s.

hep-ex

Precise Measurement of pi+ -> e+ nu Branching Ratio

The PEN Collaboration is conducting a new measurement of the pi+ -> e+ nu branching ratio at the Paul Scherrer Institute, with the goal uncertainty of delta B/B(pie2)=5E-4 or lower. At present, the combined accuracy of all published pie2 decay measurements lags behind the theoretical calculation by a factor of 40. In this contribution we report on the PEN detector configuration and its performance during two development runs done in 2007 and 2008.

hep-ex

The automatic gain-matching in the PIBETA CsI calorimeter

Segmented electromagnetic calorimeters are used to determine both the total energy and direction (momentum components) of charged particles and photons. A trade off is involved in selecting the degree of segmentation of the calorimeter as the spatial and energy resolutions are affected differently. Increased number of individual detectors reduces accidental particle pile-up per detector but introduces complications related to ADC pedestals and pedestal variations, exacerbates the effects of electronic noise and ground loops, and requires summing and discrimination of multiple analog signals. Moreover, electromagnetic showers initiated by individual ionizing particles spread over several detectors. This complicates the precise gain-matching of the detector elements which requires an iterative procedure. The PIBETA calorimeter is a 240-module pure CsI non-magnetic detector optimized for detection of photons and electrons in the energy range 5-100 MeV. We present the computer-controlled, automatic, in situ gain-matching procedure that we developed and used routinely in several rare pion and muon decay experiments with the PIBETA detector.

physics.ins-det

Measurement of stopping beam distributions in the PIBETA detector

Precise calculation of the geometrical acceptance of a large solid angle detector with an integrated stopping target relies on precise knowledge of the beam geometry. We describe four alternative methods that we used to measure the beam stopping distributions in the PIBETA detector active target: (i) light response of segmented target elements to incident beam particles, (ii) back-tracking of charged particles from pi+ and mu+ decays using multi-wire proportional chambers, (iii) volume distribution of the Dalitz decay (pi0->gamma e+e-) event vertices, and (iv) the opening angle distribution of two pi0 photons originating from the beta decay of pi+ at rest. We demonstrate consistent results obtained by these four independent approaches and show how particular beam stopping distributions affect the detector's geometrical acceptance.

hep-ex

Precise Measurement of the Pi+ -> Pi0 e+ nu Branching Ratio

Using a large acceptance calorimeter and a stopped pion beam we have made a precise measurement of the rare Pi+ -> Pi0 e+ Nu,(pi_beta) decay branching ratio. We have evaluated the branching ratio by normalizing the number of observed pi_beta decays to the number of observed Pi+ -> e+ Nu, (pi_{e2}) decays. We find the value of Gamma(Pi+ -> Pi0 e+ Nu)/Gamma(total) = [1.036 +/- 0.004(stat.) +/- 0.004(syst.) +/- 0.003(pi_{e2})] x 10^{-8}$, where the first uncertainty is statistical, the second systematic, and the third is the pi_{e2} branching ratio uncertainty. Our result agrees well with the Standard Model prediction.

hep-ex

Precise Measurement of the Pion Axial Form Factor in the Pi+ -> e+ nu gamma Decay

We have studied radiative pion decays Pi+ -> e+ nu gamma in three broad kinematic regions using the PIBETA detector and a stopped pion beam. Based on Dalitz distributions of 42,209 events we have evaluated absolute Pi -> e nu gamma branching ratios in the three regions. Minimum chi^2 fits to the integral and differential (E(e+),E(gamma)) distributions result in the axial-to-vector weak form factor ratio of gamma = F_A/F_V = 0.443(15),or F_A = 0.0115(4) with F_V = 0.0259. However, deviations from Standard Model predictions in the high-E(gamma)/low-E(e+) kinematic region indicate the need for further theoretical and experimental work.

hep-ex