Searcharxiv⌕ Search

arXiv subjects

M. C. Petrucci

Publications and source records attributed to M. C. Petrucci.

6 recordsLinked to original sources

First observation and study of the $K^{\pm} \rightarrow π^{0} π^{0} μ^{\pm} ν$ decay

The NA48/2 experiment at CERN reports the first observation of the $K^{\pm} \rightarrow π^{0} π^{0} μ^{\pm} ν$ decay based on a sample of 2437 candidates with 15% background contamination collected in 2003--2004. The decay branching ratio in the kinematic region of the squared dilepton mass above $0.03$~GeV$^2/c^4$ is measured to be $(0.65 \pm 0.03) \times 10^{-6}$. The extrapolation to the full kinematic space, using a specific model, is found to be $(3.45 \pm 0.16) \times 10^{-6}$, in agreement with chiral perturbation theory predictions.

hep-ex↗

Measurement of the branching ratio of the decay $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$

From the 2002 data taking with a neutral kaon beam extracted from the CERN-SPS, the NA48/1 experiment observed 97 $Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$ candidates with a background contamination of $30.8 \pm 4.2$ events. From this sample, the BR($Ξ^{0}\rightarrow Σ^{+} μ^{-} \barν_μ$) is measured to be $(2.17 \pm 0.32_{\mathrm{stat}}\pm 0.17_{\mathrm{syst}})\times10^{-6}$.

hep-ex↗

Empirical parameterization of the K+- -> pi+- pi0 pi0 decay Dalitz plot

As first observed by the NA48/2 experiment at the CERN SPS, the $\p0p0$ invariant mass (M00) distribution from $\kcnn$ decay shows a cusp-like anomaly at M00=2m+, where m+ is the charged pion mass. An analysis to extract the pi pi scattering lengths in the isospin I=0 and I=2 states, a0 and a2, respectively, has been recently reported. In the present work the Dalitz plot of this decay is fitted to a new empirical parameterization suitable for practical purposes, such as Monte Carlo simulations of K+- -> pi+- pi0 pi0 decays.

hep-ex↗

The design and performance of the ZEUS Micro Vertex detector

In order to extend the tracking acceptance, to improve the primary and secondary vertex reconstruction and thus enhancing the tagging capabilities for short lived particles, the ZEUS experiment at the HERA Collider at DESY installed a silicon strip vertex detector. The barrel part of the detector is a 63 cm long cylinder with silicon sensors arranged around an elliptical beampipe. The forward part consists of four circular shaped disks. In total just over 200k channels are read out using $2.9 {\rm m^2}$ of silicon. In this report a detailed overview of the design and construction of the detector is given and the performance of the completed system is reviewed.

physics.ins-det↗

Relevant results from the NA48 experiment

We report relevant results from NA48 experiment at CERN SPS. NA48 was proposed in 1990 \cite{proposal} to study direct CP violation in $K^0\toππ$ to a level of accuracy sufficient to resolve the inconclusive status left by the previous measurements performed by NA31 \cite{NA31} and E731 \cite{E731}. In 2002 NA48 published the final result \cite{NA48epsoeps}. Small modification to the experimental setup have allowed NA48 to go forward with an extensive investigation of $K^0$ rare decays and hyperon decays. Some results are already available and reported here together with the final CP violation measurement.

hep-ex↗

Beam Test of Silicon Strip Sensors for the ZEUS Micro Vertex Detector

For the HERA upgrade, the ZEUS experiment has designed and installed a high precision Micro Vertex Detector (MVD) using single sided micro-strip sensors with capacitive charge division. The sensors have a readout pitch of 120 microns, with five intermediate strips (20 micron strip pitch). An extensive test program has been carried out at the DESY-II testbeam facility. In this paper we describe the setup developed to test the ZEUS MVD sensors and the results obtained on both irradiated and non-irradiated single sided micro-strip detectors with rectangular and trapezoidal geometries. The performances of the sensors coupled to the readout electronics (HELIX chip, version 2.2) have been studied in detail, achieving a good description by a Monte Carlo simulation. Measurements of the position resolution as a function of the angle of incidence are presented, focusing in particular on the comparison between standard and newly developed reconstruction algorithms.

hep-ex↗