SearcharxivSearch

arXiv subjects

M. Caprai

Publications and source records attributed to M. Caprai.

13 recordsLinked to original sources

Proton irradiation on Hydrogenated Amorphous Silicon flexible devices

Radiation damage tests in hydrogenated amorphous silicon (a-Si:H) flexible flux and dose-measuring devices have been performed with a 3 MeV proton beam, to evaluate combined displacement and total ionizing dose damage. The tested devices had two different configurations and thicknesses. The first device was a 2 um thick n-i-p diode having a 5 mm x 5 mm area. The second device was a 5 um thick charge selective contact detector having the same area. Both the devices were deposited on a flexible polyimide substrate and were irradiated up to the fluence of 1016 neq/cm2. The response to different proton fluxes has been measured before irradiation and after irradiation at 1016 neq/cm2 for charge-selective contacts and n-i-p devices. The effect of annealing for partial performance recovery at 100{\deg}C for 12 hours was also studied and a final characterization on annealed devices was performed. This test is the first combined displacement and total ionizing dose test on flexible a-Si:H devices.

physics.ins-det

Characterization of hydrogenated amorphous silicon sensors on polyimide flexible substrate

Hydrogenated amorphous silicon (a-Si:H) is a material having an intrinsically high radiation hardness that can be deposited on flexible substrates like Polyimide. For these properties a-Si:H can be used for the production of flexible sensors. a-Si:H sensors can be successfully utilized in dosimetry, beam monitoring for particle physics (x-ray, electron, gamma-ray and proton detection) and radiotherapy, radiation flux measurement for space applications (study of solar energetic particles and stellar events) and neutron flux measurements. In this paper we have studied the dosimetric x-ray response of n-i-p diodes deposited on Polyimide. We measured the linearity of the photocurrent response to x-rays versus dose-rate from which we have extracted the dosimetric x-ray sensitivity at various bias voltages. In particular low bias voltage operation has been studied to assess the high energy efficiency of these kind of sensor. A measurement of stability of x-ray response versus time has been shown. The effect of detectors annealing has been studied. Operation under bending at various bending radii is also shown.

physics.ins-det

Development of thin hydrogenated amorphous silicon detectors on a flexible substrate

The HASPIDE (Hydrogenated Amorphous Silicon PIxels DEtectors) project aims at the development of thin hydrogenated amorphous silicon (a-Si:H) detectors on flexible substrates (mostly Polyimide) for beam monitoring, neutron detection and space applications. Since a-Si:H is a material with superior radiation hardness, the benefit for the above-mentioned applications can be appreciated mostly in radiation harsh environments. Furthermore, the possibility to deposit this material on flexible substrates like Polyimide (PI), polyethylene naphthalate (PEN) or polyethylene terephthalate (PET) facilitates the usage of these detectors in medical dosimetry, beam flux and beam profile measurements. Particularly interesting is its use when positioned directly on the flange of the vacuum-to-air separation interface in a beam line, as well as other applications where a thin self-standing radiation flux detector is envisaged. In this paper, the HASPIDE project will be described and some preliminary results on PI and glass substrates will be reported.

physics.ins-det

Prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Commissioning the Optical System

A prototype Schwarzschild-Couder Telescope (pSCT) has been constructed at the Fred Lawrence Whipple Observatory as a candidate for the medium-sized telescopes of the Cherenkov Telescope Array Observatory (CTAO). CTAO is currently entering early construction phase of the project and once completed it will vastly improve very high energy gamma-ray detection component in multi-wavelength and multi-messenger observations due to significantly improved sensitivity, angular resolution and field of view comparing to the current generation of the ground-based gamma-ray observatories H.E.S.S., MAGIC and VERITAS. The pSCT uses a dual aspheric mirror design with a $9.7$ m primary mirror and $5.4$ m secondary mirror, both of which are segmented. The Schwarzschild-Couder (SC) optical system (OS) selected for the prototype telescope achieves wide field of view of $8$ degrees and simultaneously reduces the focal plane plate scale allowing an unprecedented compact ($0.78$m diameter) implementation of the high-resolution camera ($6$mm/ $0.067$deg per imaging pixel with $11,328$ pixels) based on the silicon photo-multipliers (SiPMs). The OS of the telescope is designed to eliminate spherical and comatic aberrations and minimize astigmatism to radically improve off-axis imaging and consequently angular resolution across all the field of view with respect to the conventional single-mirror telescopes. Fast and high imaging resolution OS of the pSCT comes with the challenging submillimeter-precision custom alignment system, which was successfully demonstrated with an on-axis point spread function (PSF) of $2.9$ arcmin prior to the first-light detection of the Crab Nebula in 2020. Ongoing and future commissioning activities are reported.

astro-ph.IM

Testing of planar hydrogenated amorphous silicon sensors with charge selective contacts for the construction of 3D- detectors

Hydrogenated Amorphous Silicon (a-Si:H) is a material well known for its intrinsic radiation hardness and is primarily utilized in solar cells as well as for particle detection and dosimetry. Planar p-i-n diode detectors are fabricated entirely by means of intrinsic and doped PECVD of a mixture of Silane (SiH4) and molecular Hydrogen. In order to develop 3D detector geometries using a-Si:H, two options for the junction fabrication have been considered: ion implantation and charge selective contacts through atomic layer deposition. In order to test the functionality of the charge selective contact electrodes, planar detectors have been fabricated utilizing this technique. In this paper, we provide a general overview of the 3D fabrication project followed by the results of leakage current measurements and x-ray dosimetric tests performed on planar diodes containing charge selective contacts to investigate the feasibility of the charge selective contact methodology for integration with the proposed 3D detector architectures.

physics.ins-det

Detection of the Crab Nebula by the prototype Schwarzschild-Couder Telescope

The Schwarzschild-Couder Telescope (SCT) is a medium-sized telescope technology proposed for the Cherenkov Telescope Array. It uses a novel dual-mirror optical design that removes comatic aberrations across its entire field of view. The SCT camera employs high-resolution silicon photomultiplier (SiPM) sensors with a pixel size of 4 arcminutes. A prototype SCT (pSCT) has been constructed at the Fred Lawrence Whipple Observatory in Arizona, USA. An observing campaign in 2020, with a partial camera of 1600 pixels (2.7 degrees by 2.7 degrees field of view) resulted in detection of the Crab Nebula at 8.6 sigma statistical significance. Work on the pSCT camera and optical system is ongoing to improve performance and prepare for an upcoming camera upgrade. The pSCT camera upgrade will replace the current camera modules with improved SiPMs and readout electronics and will expand the camera to its full design field of view of 8 degrees in diameter (11,328 pixels). The fully upgraded pSCT will enable next-generation very-high-energy gamma-ray astrophysics through excellent background rejection and angular resolution. In this presentation we describe first results from the successful operation of the pSCT and future plans.

astro-ph.IM

Design and performance of the prototype Schwarzschild-Couder Telescope camera

The Cherenkov Telescope Array (CTA) is the next-generation ground-based observatory for very-high-energy gamma-ray astronomy. An innovative 9.7 m aperture, dual-mirror Schwarzschild-Couder Telescope (SCT) design is a candidate design for CTA Medium-Sized Telescopes. A prototype SCT (pSCT) has been constructed at the Fred Lawrence Whipple Observatory in Arizona, USA. Its camera is currently partially instrumented with 1600 pixels covering a field of view of 2.7 degrees square. The small plate scale of the optical system allows densely packed silicon photomultipliers to be used, which combined with high-density trigger and waveform readout electronics enable the high-resolution camera. The camera's electronics are capable of imaging air shower development at a rate of one billion samples per second. We describe the commissioning and performance of the pSCT camera, including trigger and waveform readout performance, calibration, and absolute GPS time stamping. We also present the upgrade to the camera, which is currently underway. The upgrade will fully populate the focal plane, increasing the field of view to 8 degree diameter, and lower the front-end electronics noise, enabling a lower trigger threshold and improved reconstruction and background rejection.

astro-ph.IM

Sensitivity of the Cherenkov Telescope Array for probing cosmology and fundamental physics with gamma-ray propagation

The Cherenkov Telescope Array (CTA), the new-generation ground-based observatory for $γ$-ray astronomy, provides unique capabilities to address significant open questions in astrophysics, cosmology, and fundamental physics. We study some of the salient areas of $γ$-ray cosmology that can be explored as part of the Key Science Projects of CTA, through simulated observations of active galactic nuclei (AGN) and of their relativistic jets. Observations of AGN with CTA will enable a measurement of $γ$-ray absorption on the extragalactic background light with a statistical uncertainty below 15% up to a redshift $z=2$ and to constrain or detect $γ$-ray halos up to intergalactic-magnetic-field strengths of at least 0.3pG. Extragalactic observations with CTA also show promising potential to probe physics beyond the Standard Model. The best limits on Lorentz invariance violation from $γ$-ray astronomy will be improved by a factor of at least two to three. CTA will also probe the parameter space in which axion-like particles could constitute a significant fraction, if not all, of dark matter. We conclude on the synergies between CTA and other upcoming facilities that will foster the growth of $γ$-ray cosmology.

astro-ph.HE

Detection of the Crab Nebula with the 9.7 m Prototype Schwarzschild-Couder Telescope

The Schwarzschild-Couder Telescope (SCT) is a telescope concept proposed for the Cherenkov Telescope Array. It employs a dual-mirror optical design to remove comatic aberrations over an $8^{\circ}$ field of view, and a high-density silicon photomultiplier camera (with a pixel resolution of 4 arcmin) to record Cherenkov emission from cosmic ray and gamma-ray initiated particle cascades in the atmosphere. The prototype SCT (pSCT), comprising a 9.7 m diameter primary mirror and a partially instrumented camera with 1536 pixels, has been constructed at the Fred Lawrence Whipple Observatory. The telescope was inaugurated in January 2019, with commissioning continuing throughout 2019. We describe the first campaign of observations with the pSCT, conducted in January and February of 2020, and demonstrate the detection of gamma-ray emission from the Crab Nebula with a statistical significance of $8.6σ$.

astro-ph.IM

Verification of the Optical System of the 9.7-m Prototype Schwarzschild-Couder Telescope

For the first time in the history of ground-based $γ$-ray astronomy, the on-axis performance of the dual mirror, aspheric, aplanatic Schwarzschild-Couder optical system has been demonstrated in a $9.7$-m aperture imaging atmospheric Cherenkov telescope. The novel design of the prototype Schwarzschild-Couder Telescope (pSCT) is motivated by the need of the next-generation Cherenkov Telescope Array (CTA) observatory to have the ability to perform wide ($\geq 8^{\circ}$) field-of-view observations simultaneously with superior imaging of atmospheric cascades (resolution of $0.067^{\circ}$ per pixel or better). The pSCT design, if implemented in the CTA installation, has the potential to improve significantly both the $γ$-ray angular resolution and the off-axis sensitivity of the observatory, reaching nearly the theoretical limit of the technique and thereby making a major impact on the CTA observatory sky survey programs, follow-up observations of multi-messenger transients with poorly known initial localization, as well as on the spatially resolved spectroscopic studies of extended $γ$-ray sources. This contribution reports on the initial alignment procedures and point-spread-function results for the challenging segmented aspheric primary and secondary mirrors of the pSCT.

astro-ph.IM

Camera design and performance of the prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array

The Schwarzschild-Couder Telescope (SCT) is a candidate technology for a medium-sized telescope within the Cherenkov Telescope Array, the next generation ground based observatory for very high energy gamma ray astronomy. The SCT uses a novel two-mirror design and is expected to yield improvements in field of view and image resolution compared to traditional Cherenkov telescopes based on single-mirror-dish optics. To match the improved optical resolution, challenging requirements of high channel count and density at low power consumption must be overcome by the camera. The prototype camera, currently commissioned and tested on the prototype SCT, has been developed based on millimeter scale SiPM pixels and a custom high density digitizer ASIC, TARGET, to provide 1600 pixels spanning a 2.7 degree field of view while being able to sample nanosecond photon pulses. It is mechanically designed to allow for an upgrade to 11,328 pixels covering a field of view of 8 degrees and demonstrating the full potential of the technology. The camera was installed on the telescope in 2018. We will present its design and performance including first light data.

astro-ph.IM

Prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Commissioning Status of the Optical System

The Cherenkov Telescope Array (CTA), with more than 100 telescopes, will be the largest ever ground-based gamma-ray observatory and is expected to greatly improve on both gamma-ray detection sensitivity and energy coverage compared to current-generation detectors. The 9.7-m Schwarzschild-Couder telescope (SCT) is one of the two candidates for the medium size telescope (MST) design for CTA. The novel aplanatic dual-mirror SCT design offers a wide field-of-view with a compact plate scale, allowing for a large number of camera pixels that improves the angular resolution and reduce the night sky background noise per pixel compared to the traditional single-mirror Davies-Cotton (DC) design of ground-based gamma-ray telescopes. The production, installation, and the alignment of the segmented aspherical mirrors are the main challenges for the realization of the SCT optical system. In this contribution, we report on the commissioning status, the alignment procedures, and initial alignment results during the initial commissioning phase of the optical system of the prototype SCT.

astro-ph.IM

Development and operations of INFN optical modules for the SCT Telescope camera proposed for the Cherenkov Telescope Array Observatory

The Schwarzschild-Couder Telescope (SCT) is a proposal for the Medium Size Telescopes of the Cherenkov Telescope Array. Its concept is based on a two-mirror optical system designed to improve the telescope field of view and image resolution with respect to the single mirror Davies-Cotton solution. The SCT camera is planned to be instrumented with 177 photodetection modules, each composed of 64 Silicon Photomultiplier (SiPM) pixels. The third generation of $6 x 6~mm^2$ high density NUV SiPMs (NUV-HD3) produced by Fondazione Bruno Kessler (FBK) in collaboration with INFN has been used to equip optical units to be integrated on the upgrade of the camera of the SCT prototype (pSCT). Each optical unit is composed of an array of 16 NUV-HD3 SiPMs coupled with the front-end electronics, which is designed for full-waveform nanosecond readout and digitization using the TARGET-7 ASIC. Several optical units have been assembled and tested in the laboratories of INFN and have been integrated on the camera of the pSCT telescope, that is currently operating at the Fred Lawrence Whipple Observatory. In this contribution we report on the development, assembly and calibration of the optical units that are currently taking data on the pSCT camera.

astro-ph.IM