Searcharxiv⌕ Search

arXiv subjects

M. D. K. Lee

Publications and source records attributed to M. D. K. Lee.

7 recordsLinked to original sources

Lu$^+$ optical frequency references with accuracy verified at the 19th digit

We report a comprehensive evaluation of all known sources of systematic uncertainty for two independent $^{176}$Lu$^+$ single-ion optical references, finding total systematic uncertainty of $1.2\times10^{-19}$ and $1.3\times10^{-19}$ for the two individual systems and $1.0\times10^{-19}$ for the difference. Through direct comparison via correlation spectroscopy, we demonstrate a relative frequency agreement of $-0.1\pm(5.7)_\mathrm{stat}\pm(1.0)_\mathrm{sys}\times10^{-19}$, where `stat' and `sys' indicate the statistical and systematic uncertainty, respectively. The comparison uncertainty is statistically limited after approximately 200 hours of averaging with a measurement instability of $4.8\times10^{-16}(τ/\mathrm{s})^{-1/2}$.

physics.atom-ph↗

Absolute frequency measurement of a $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty

We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of $353\,638\,794\,073\,800.332(91)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.

physics.atom-ph↗

Precision measurement of the $^{176}\mathrm{Lu}^+$ $^3D_1$ microwave clock transitions

We report precision measurement of the unperturbed ${^{3}}D_1$ microwave transition frequencies in $^{176}\mathrm{Lu}^+$ to a fractional uncertainty of $4\times10^{-14}$. We find the $|F,m_F\rangle=|8,0\rangle$ to $|7,0\rangle$ hyperfine transition frequency to be $10\,491\,519\,945.228\,82(38)\,$Hz and the $|7,0\rangle$ to $|6,0\rangle$ transition frequency to be $11\,290\,004\,289.881\,61(36)\,$ Hz. At this precision we are able to observe the hyperfine-mediated effects in the ratio of the quadrupole shifts, from which we can directly infer the residual quadrupole moment after $^3D_1$ hyperfine averaging. We find a residual quadrupole moment of ${-2.48(23)\times10^{-4}}\,e a_0^2$, consistent with a previous assessment using a different and less direct method. With the unperturbed microwave frequencies accurately known, the residual quadrupole shift for a $^{176}\mathrm{Lu}^+$ ($^3D_1$) optical frequency standard can henceforth be readily evaluated to $<10^{-20}$ uncertainty by routine ${^{3}}{D}_1$ microwave spectroscopy.

physics.atom-ph↗

Measurement of the reduced dipole matrix element in Ba$^+$

We present a high-precision measurement of the reduced electric-dipole matrix element $\langle P_{1/2}\|r\|S_{1/2}\rangle$ in $^{138}\mathrm{Ba}^+$. By comparing off-resonant scattering rates with dispersive Stark-shift measurements, we determine the matrix element to be $3.322\,7(12)$, corresponding to a $P_{1/2}$ excited-state radiative lifetime of $7.866\,3(56)$~ns. Combining our experimental results with a prior model for the differential scalar polarizability $Δα_0(ω)$, we extract the static value $Δα_0(0) = -73.09(12)$a.u. This determination directly improves the evaluation of the blackbody radiation (BBR) shift, minimizing a prominent systematic limitation in room-temperature $\mathrm{Ba}^+$ optical clock error budgets. These results provide a stringent benchmark for atomic-structure calculations and advance high-precision applications in quantum metrology and tests of fundamental physics.

physics.atom-ph↗

Zeeman Degenerate Sideband Cooling in $^{176}$Lu$^+$

We explore degenerate Raman sideband cooling in which neighboring Zeeman states of a fixed hyperfine level are coupled via a two-photon Raman transition. The degenerate coupling between $|F,m_F\rangle\rightarrow |F,m_F-1\rangle$ facilitates the removal of multiple motional quanta in a single cycle. This method greatly reduces the number of cooling cycles required to reach the ground state compared to traditional sideband cooling. We show that near ground state cooling can be achieved with a pulse number as low as $\bar{n}$ where $\bar{n}$ is the average phonon number in the initial thermal state. We demonstrate proof-of-concept in $^{176}\mathrm{Lu}^+$ by coupling neighboring Zeeman levels on the motional sideband for the $F=7$ hyperfine level in $^3D_1$. Starting from a thermal distribution with an average phonon number of 6, we demonstrate near ground-state cooling with $\sim10$ pulses. A theoretical description is given that applies to any $F$ level and demonstrates how effective this approach can be.

quant-ph↗

Lande g-factor measurements for the 5d6s 3D2 hyperfine levels of 176Lu+

We report measurements of the Lande g-factors for the 5d6s $^3$D$_2$ hyperfine levels of $^{176}$Lu$^+$ to a fractional inaccuracy of $5\times 10^{-7}$. Combining these measurements with theoretical calculations allows us to estimate hyperfine-mediated modifications to the quadrupole moments for each state and infer a value of $δΘ= 1.59(34)\times 10^{-4} \,ea_0^2$ for the residual quadrupole moment of the $^1S_0\leftrightarrow{^3}D_2$ hyperfine-averaged clock transition.

physics.atom-ph↗

Absolute frequency measurement of a Lu$^+$ $(^{3}\rm D_1)$ optical frequency standard via link to international atomic time

We report on an absolute frequency measurement of the ${\rm Lu}^{+}\,(^{3}\rm D_1)$ standard frequency which is defined as the hyperfine-average of $^{1}\rm S_0$ to $^{3}\rm D_1$ optical clock transitions in $^{176}{\rm Lu}^{+}$. The measurement result of $353\,638\,794\,073\,800.35(33)$Hz with a fractional uncertainty of $9.2 \times 10^{-16}$ was obtained by operating a single-ion $^{176}{\rm Lu}^{+}$ frequency standard intermittently over 3 months with a total uptime of 162 hours. Traceability to the International System of Units (SI) is realized by remote link to International Atomic Time. This is the first reported absolute frequency value for a ${\rm Lu}^{+}\,(^{3}\rm D_1)$ optical frequency standard.

physics.atom-ph↗