SearcharxivSearch

arXiv subjects

M. Danielsson

Publications and source records attributed to M. Danielsson.

4 recordsLinked to original sources

Photon-counting spectral phase-contrast mammography

Phase-contrast imaging is an emerging technology that may increase the signal-difference-to-noise ratio in medical imaging. One of the most promising phase-contrast techniques is Talbot interferometry, which, combined with energy-sensitive photon-counting detectors, enables spectral differential phase-contrast mammography. We have evaluated a realistic system based on this technique by cascaded-systems analysis and with a task-dependent ideal-observer detectability index as a figure-of-merit. Beam-propagation simulations were used for validation and illustration of the analytical framework. Differential phase contrast improved detectability compared to absorption contrast, in particular for fine tumor structures. This result was supported by images of human mastectomy samples that were acquired with a conventional detector. The optimal incident energy was higher in differential phase contrast than in absorption contrast when disregarding the setup design energy. Further, optimal weighting of the transmitted spectrum was found to have a weaker energy dependence than for absorption contrast. Taking the design energy into account yielded a superimposed maximum on both detectability as a function of incident energy, and on optimal weighting. Spectral material decomposition was not facilitated by phase contrast, but phase information may be used instead of spectral information.

physics.med-ph

Study of capillary-based gaseous detectors

We have studied gain vs. voltage characteristics and position resolutions of multistep capillary plates (two or three capillary plates operating in a cascade), as well as capillary plates operating in a mode when the main amplification occurs between plates or between the capillary plate and the readout plate (parallel plate amplification mode). Results of these studies demonstrated that in the parallel-plate amplification mode one can reach both high gains (>100000) and good position resolutions (~100 micro meter) even with a single step arrangement. It offers a compact amplification structure, which can be used in many applications. For example, in preliminary tests we succeeded to combine it with a photocathode and use it as a position sensitive gaseous photomultiplier. CsI coated capillary plates could also be used as a high position resolution and high rate X-ray converter.

physics.ins-det

Sporadic electron jets from cathodes - The main breakdown-triggering mechanism in gaseous detectors

We have demonstrated experimentally that the main breakdown-triggering mechanism in most gaseous detectors, including micropattern gaseous detectors, is sporadic electron jets from the cathode surfaces. Depending on conditions, each jet contains randomly from a few primary electrons up to 10^5, emitted in a time interval ranging between 0.1 microsecond to milliseconds. After the emission, these primary electrons experience a full gas multiplication in the detector and create spurious pulses. The rate of these jets increases with applied voltage and very sharply at voltages close to the breakdown limit. We found that these jets are in our measurements responsible for the breakdown-triggering at any counting rate between 10^(-2) Hz/mm^2 and 10^8 Hz/mm^2. We demonstrated on a few detectors that an optimized cathode-geometry, a high electrode surface quality and a proper choice of the gas mixture, considerably improve the performance characteristics and provide the highest possible gains.

physics.ins-det

Fundamentals of Gas Micropattern Detectors

We performed a new series of systematic studies of gain and rate characteristics of several micropattern gaseous detectors. Extending earlier studies, these measurements were done at various pressures, gas mixtures, at a wide range of primary charges and also when the whole area of the detectors was irradiated with a high intensity x-ray beam. Several new effects were discovered, common to all tested detectors, which define fundamental limits of operation. The results of these studies allow us to identify several concrete ways of improving the performance of micropattern detectors and to suggest that in some applications RPCs may constitute a valid alternative. Being protected from damaging discharges by the resistive electrodes, these detectors feature high gain, high rate capability (10^5 Hz/mm^2), good position resolution (better than 30 micrometer) and excellent timing (50 ps sigma).

physics.ins-det