SearcharxivSearch

arXiv subjects

M. Eads

Publications and source records attributed to M. Eads.

14 recordsLinked to original sources

An improved direct limit on the muon electric dipole moment

A limit on the permanent electric dipole moment (EDM) of the positive muon is presented based on data from the Fermilab Muon g-2 Experiment taken between 2019 and 2020. The tracking detectors measure the average vertical decay angle of positrons from muon decays, enabling a search for an interaction between a possible muon EDM $d_\mu$ and the lab-frame magnetic field. The result, $d_\mu = (-0.35 \pm 0.19_{\mathrm{stat}} \pm 0.34_{\mathrm{sys}}) \times10^{-19}~e\cdot$cm, is consistent with zero and sets a new direct limit on the muon EDM of $|d_\mu|<1.10\times10^{-19}~e\cdot$cm at the 95 percent confidence level.

hep-ex

Final Report on the Measurement of the Positive Muon Anomalous Magnetic Moment at Fermilab to 127 ppb

This report details the final measurement of the muon magnetic anomaly, $a_{\mu}=(g_{\mu}-2)/2$, by the Muon $g-2$ experiment at Fermi National Accelerator Laboratory (FNAL), using positive muons collected from 2021 to 2023. The value of $a_{\mu}$ is determined from the ratio of the anomalous spin precession frequency to the shielded proton precession frequency in the muon storage ring magnetic field, combined with external constants known at the 22 ppb level. The new dataset, containing over $2.5$ times the statistics of our previous results, yields $a_{\mu}=116\,592\,0710(162)\times 10^{-12}$ (139 ppb), or $a_{\mu}=116\,592\,0705(148)\times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_{\mu}^{\text{Exp}}=116\,592\,0715(145)\times 10^{-12}$ (124 ppb).

hep-ex

Cryogenic characterization of FBK NUV-HD-Cryo 3T SiPM sensors for the DUNE photon detection system

The Deep Underground Neutrino Experiment (DUNE) is a long-baseline neutrino experiment based in the USA and composed of a Near Detector (ND) complex at Fermi National Laboratory (FNAL), and a Far Detector (FD) complex located at the Sanford Underground Research Facility (SURF) $\sim$1300\,km distant. DUNE will study neutrino oscillations looking for unresolved issues of the Standard Model of particle physics (SM) such as CP violation in the leptonic sector, neutrino mass ordering and others, starting from the early 2030s. The FD, with a mass of $\sim$17\,kt, that will exploit both ionization and scintillation signals to detect neutrino interactions with Argon. Scintillating photons in LAr will be detected by the photon detection system (PDS) based on light collectors coupled to Silicon Photomultipliers (SiPMs). During a test campaign, different laboratories of the collaboration performed an investigation of the best SiPM candidates that fulfill the DUNE FD requirements. We identified two models of SiPM, produced by Hamamatsu Photonics K.K. (HPK) and Fondazione Bruno Kessler (FBK), respectively. In this paper, we focus on the FBK selected model showing its main features. We will describe the characterization protocol, the results at both room and cryogenic temperatures and the photon detection efficiency measurements.

physics.ins-det

Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb

A new measurement of the magnetic anomaly $a_{\mu}$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine $a_{\mu} = 116\,592\,0710(162) \times 10^{-12}$ (139 ppb) for the new datasets, and $a_{\mu} = 116\,592\,0705(148) \times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_{\mu}(\text{exp}) =116\,592\,0715(145) \times 10^{-12}$ (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of four.

hep-ex

Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present details on a new measurement of the muon magnetic anomaly, $a_\mu = (g_\mu -2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_{\mu}$ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using Nuclear Magnetic Resonance (NMR). The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure $a_\mu = 116 592 057 (25) \times 10^{-11}$ (0.21 ppm). This is the world's most precise measurement of this quantity and represents a factor of $2.2$ improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield $a_\mu(\text{FNAL}) = 116 592 055 (24) \times 10^{-11}$ (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is $a_\mu$(exp) $ = 116 592 059 (22) \times 10^{-11}$ (0.19 ppm).

hep-ex

Physics Opportunities at a Beam Dump Facility at PIP-II at Fermilab and Beyond

The Fermilab Proton-Improvement-Plan-II (PIP-II) is being implemented in order to support the precision neutrino oscillation measurements at the Deep Underground Neutrino Experiment, the U.S. flagship neutrino experiment. The PIP-II LINAC is presently under construction and is expected to provide 800~MeV protons with 2~mA current. This white paper summarizes the outcome of the first workshop on May 10 through 13, 2023, to exploit this capability for new physics opportunities in the kinematic regime that are unavailable to other facilities, in particular a potential beam dump facility implemented at the end of the LINAC. Various new physics opportunities have been discussed in a wide range of kinematic regime, from eV scale to keV and MeV. We also emphasize that the timely establishment of the beam dump facility at Fermilab is essential to exploit these new physics opportunities.

hep-ex

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

We present a new measurement of the positive muon magnetic anomaly, $a_\mu \equiv (g_\mu - 2)/2$, from the Fermilab Muon $g\!-\!2$ Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, $\tilde{\omega}'^{}_p$, and of the anomalous precession frequency corrected for beam dynamics effects, $\omega_a$. From the ratio $\omega_a / \tilde{\omega}'^{}_p$, together with precisely determined external parameters, we determine $a_\mu = 116\,592\,057(25) \times 10^{-11}$ (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain $a_\mu\text{(FNAL)} = 116\,592\,055(24) \times 10^{-11}$ (0.20 ppm). The new experimental world average is $a_\mu (\text{Exp}) = 116\,592\,059(22)\times 10^{-11}$ (0.19 ppm), which represents a factor of 2 improvement in precision.

hep-ex

The Straw Tracking Detector for the Fermilab Muon $g-2$ Experiment

The Muon $g-2$ Experiment at Fermilab uses a gaseous straw tracking detector to make detailed measurements of the stored muon beam profile, which are essential for the experiment to achieve its uncertainty goals. Positrons from muon decays spiral inward and pass through the tracking detector before striking an electromagnetic calorimeter. The tracking detector is therefore located inside the vacuum chamber in a region where the magnetic field is large and non-uniform. As such, the tracking detector must have a low leak rate to maintain a high-quality vacuum, must be non-magnetic so as not to perturb the magnetic field and, to minimize energy loss, must have a low radiation length. The performance of the tracking detector has met or surpassed the design requirements, with adequate electronic noise levels, an average straw hit resolution of $(110 \pm 20) \,\mu$m, a detection efficiency of 97% or higher, and no performance degradation or signs of aging. The tracking detector's measurements result in an otherwise unachievable understanding of the muon's beam motion, particularly at early times in the experiment's measurement period when there are a significantly greater number of muons decaying. This is vital to the statistical power of the experiment, as well as facilitating the precise extraction of several systematic corrections and uncertainties. This paper describes the design, construction, testing, commissioning, and performance of the tracking detector.

physics.ins-det

Beam dynamics corrections to the Run-1 measurement of the muon anomalous magnetic moment at Fermilab

This paper presents the beam dynamics systematic corrections and their uncertainties for the Run-1 data set of the Fermilab Muon g-2 Experiment. Two corrections to the measured muon precession frequency $ω_a^m$ are associated with well-known effects owing to the use of electrostatic quadrupole (ESQ) vertical focusing in the storage ring. An average vertically oriented motional magnetic field is felt by relativistic muons passing transversely through the radial electric field components created by the ESQ system. The correction depends on the stored momentum distribution and the tunes of the ring, which has relatively weak vertical focusing. Vertical betatron motions imply that the muons do not orbit the ring in a plane exactly orthogonal to the vertical magnetic field direction. A correction is necessary to account for an average pitch angle associated with their trajectories. A third small correction is necessary because muons that escape the ring during the storage time are slightly biased in initial spin phase compared to the parent distribution. Finally, because two high-voltage resistors in the ESQ network had longer than designed RC time constants, the vertical and horizontal centroids and envelopes of the stored muon beam drifted slightly, but coherently, during each storage ring fill. This led to the discovery of an important phase-acceptance relationship that requires a correction. The sum of the corrections to $ω_a^m$ is 0.50 $\pm$ 0.09 ppm; the uncertainty is small compared to the 0.43 ppm statistical precision of $ω_a^m$.

physics.acc-ph

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_\mu = (g^{}_\mu-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrated in terms of the equivalent proton spin precession frequency in a spherical water sample at 34.7$^\circ$C. The measured field is weighted by the muon distribution resulting in $\tilde{\omega}'^{}_p$, the denominator in the ratio $\omega^{}_a$/$\tilde{\omega}'^{}_p$ that together with known fundamental constants yields $a^{}_\mu$. The reported uncertainty on $\tilde{\omega}'^{}_p$ for the Run-1 data set is 114 ppb consisting of uncertainty contributions from frequency extraction, calibration, mapping, tracking, and averaging of 56 ppb, and contributions from fast transient fields of 99 ppb.

hep-ex

Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment

The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muon storage ring, the precession frequency measurement determines a muon magnetic anomaly of $a_μ({\rm FNAL}) = 116\,592\,040(54) \times 10^{-11}$ (0.46 ppm). This article describes the multiple techniques employed in the reconstruction, analysis and fitting of the data to measure the precession frequency. It also presents the averaging of the results from the eleven separate determinations of ω_a, and the systematic uncertainties on the result.

hep-ex

Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm

We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in a magnetic storage ring. The storage ring magnetic field is measured using nuclear magnetic resonance probes calibrated in terms of the equivalent proton spin precession frequency ${\tildeω'^{}_p}$ in a spherical water sample at 34.7$^{\circ}$C. The ratio $ω_a / {\tildeω'^{}_p}$, together with known fundamental constants, determines $a_μ({\rm FNAL}) = 116\,592\,040(54)\times 10^{-11}$ (0.46\,ppm). The result is 3.3 standard deviations greater than the standard model prediction and is in excellent agreement with the previous Brookhaven National Laboratory (BNL) E821 measurement. After combination with previous measurements of both $μ^+$ and $μ^-$, the new experimental average of $a_μ({\rm Exp}) = 116\,592\,061(41)\times 10^{-11}$ (0.35\,ppm) increases the tension between experiment and theory to 4.2 standard deviations

hep-ex

New Experiments to Measure the Muon Anomalous Gyromagnetic Moment

The magnetic moment is a fundamental property of particles. The measurement of these magnetic moments and the comparison with the values predicted by the standard model of particle physics is a way to test our understanding of the fundamental building blocks of our world. In some cases, such as for the electron, this comparison has resulted in confirmation of the standard model with incredible precision. In contrast, the magnetic moment of the muon has shown a long-standing disagreement in the measured and the predicted value. There is currently a tantalizing three-standard-deviation difference between the current best measurement (with a precision of 0.54 ppm) and the state-of-the-art standard model prediction. This represents one of the very few experimental hints for physics beyond the standard model. There are currently two major experimental efforts underway to improve the precision of the muon magnetic moment measurement. The first is an evolution of the E-821 experiment, originally located at Brookhaven National Laboratory in the United States. This is experiment, E-989, is located at Fermilab and will measure the spin precession rate of positive muons in a 14-m diameter storage ring using decay positrons. The goal of the experiment is to reduce the current experimental uncertainty by a factor of three. The experiment is currently being constructed and aims to start taking data in 2017. An alternative, and very complementary, experiment is being planned at J-PARC in Japan. This experiment, E-34, will utilize low energy, ultra-cold muons in a much smaller storage ring. This experiment aims for a similar precision to the Fermilab experiment and aims to begin data taking on a similar timescale.

hep-ex

Non-Susy Searches at the Tevatron

The CDF and D0 collaborations have results on a large number of searches for beyond-the-standard-model phenomena. This talk focuses on searches for non-supersymmetric model signatures. These results, based on between 1--2.5 fb-1 of data from p pbar collisions at the Fermilab Tevatron, include some of the world's best limits on extra dimensions models and heavy resonances.

hep-ex