Searcharxiv⌕ Search

arXiv subjects

M. Evans

Publications and source records attributed to M. Evans.

48 records · Page 3Linked to original sources

Seismic isolation of Advanced LIGO: Review of strategy, instrumentation and performance

Isolating ground-based interferometric gravitational wave observatories from environmental disturbances is one of the great challenges of the advanced detector era. In order to directly observe gravitational waves, the detector components and test masses must be highly inertially decoupled from the ground motion not only to sense the faint strain of space-time induced by gravitational waves, but also to maintain the resonance of the very sensitive 4 km interferometers. This article presents the seismic isolation instrumentation and strategy developed for Advanced LIGO interferometers. It reviews over a decade of research on active isolation in the context of gravitational wave detection, and presents the performance recently achieved with the Advanced LIGO observatory. Lastly, it discusses prospects for future developments in active seismic isolation and the anticipated benefits to astrophysical gravitational wave searches. Beyond gravitational wave research, the goal of this article is to provide detailed isolation strategy guidelines for sensitive ground-based physics experiments that may benefit from similar levels of inertial isolation.

physics.ins-det↗

Two-fluid and magnetohydrodynamic modelling of magnetic reconnection in the MAST spherical tokamak and the solar corona

Twisted magnetic flux ropes are ubiquitous in space and laboratory plasmas, and the merging of such flux ropes through magnetic reconnection is an important mechanism for restructuring magnetic fields and releasing free magnetic energy. The merging-compression scenario is one possible start up scheme for spherical tokamaks, which has been used on the Mega Amp Spherical Tokamak MAST. Two current-carrying plasma rings, or flux ropes, approach each other through the mutual attraction of their like currents, and merge, through magnetic reconnection, into a single plasma torus, with substantial plasma heating. 2D resistive MHD and Hall MHD simulations of this process are reported, and new results for the temperature distribution of ions and electrons are presented. A model of the based on relaxation theory is also described, which is now extended to tight aspect ratio geometry. This model allows prediction of the final merged state and the heating. The implications of the relaxation model for heating of the solar corona are also discussed, and a model of the merger of two or more twisted coronal flux ropes is presented, allowing for different senses of twist.

physics.plasm-ph↗

Impact of backscattered light in a squeezing-enhanced interferometric gravitational-wave detector

Squeezed states of light have been recently used to improve the sensitivity of laser interferometric gravitational-wave detectors beyond the quantum limit. To completely establish quantum engineering as a realistic option for the next generation of detectors, it is crucial to study and quantify the noise coupling mechanisms which injection of squeezed states could potentially introduce. We present a direct measurement of the impact of backscattered light from a squeezed-light source deployed on one of the 4 km long detectors of the Laser Interferometric Gravitational Wave Observatory (LIGO). We also show how our measurements inform the design of squeezed light sources compatible with the even more sensitive advanced detectors currently under construction, such as Advanced LIGO.

quant-ph↗

Loss in long-storage-time optical cavities

Long-storage-time Fabry-Perot cavities are a core component of many precision measurement experiments. Optical loss in such cavities is a critical parameter in determining their performance; however, it is very difficult to determine a priori from independent characterisation of the individual cavity mirrors. Here, we summarise three techniques for directly measuring this loss in situ and apply them to a high-finesse, near-concentric, 2 m system. Through small modifications of the cavity's length, we explore optical loss as a function of beam spot size over the 1-3 mm range. In this regime we find that optical loss is relatively constant at around 10 ppm per mirror and shows greater dependence on the positions of the beam spots on the cavity optics than on their size. These results have immediate consequences for the application of squeezed light to advanced gravitational-wave interferometers.

physics.optics↗

Realistic Filter Cavities for Advanced Gravitational Wave Detectors

The ongoing global effort to detect gravitational waves continues to push the limits of precision measurement while aiming to provide a new tool for understanding both astrophysics and fundamental physics. Squeezed states of light offer a proven means of increasing the sensitivity of gravitational wave detectors, potentially increasing the rate at which astrophysical sources are detected by more than an order of magnitude. Since radiation pressure noise plays an important role in advanced detectors, frequency dependent squeezing will be required. In this paper we propose a practical approach to producing frequency dependent squeezing for Advanced LIGO and similar interferometric gravitational wave detectors.

physics.optics↗

Brownian force noise from molecular collisions and the sensitivity of advanced gravitational wave observatories

We present an analysis of Brownian force noise from residual gas damping of reference test masses as a fundamental sensitivity limit in small force experiments. The resulting acceleration noise increases significantly when the distance of the test mass to the surrounding experimental apparatus is smaller than the dimension of the test mass itself. For the Advanced LIGO interferometric gravitational wave observatory, where the relevant test mass is a suspended 340 mm diameter cylindrical end mirror, the force noise power is increased by roughly a factor 40 by the presence of a similarly shaped reaction mass at a nominal separation of 5 mm. The force noise, of order 20 fN\rthz\ for $2 \times 10^{-6}$ Pa of residual H$_2$ gas, rivals quantum optical fluctuations as the dominant noise source between 10 and 30 Hz. We present here a numerical and analytical analysis for the gas damping force noise for Advanced LIGO, backed up by experimental evidence from several recent measurements. Finally, we discuss the impact of residual gas damping on the gravitational wave sensitivity and possible mitigation strategies.

gr-qc↗

A General Approach to Optomechanical Parametric Instabilities

We present a simple feedback description of parametric instabilities which can be applied to a variety of optical systems. Parametric instabilities are of particular interest to the field of gravitational-wave interferometry where high mechanical quality factors and a large amount of stored optical power have the potential for instability. In our use of Advanced LIGO as an example application, we find that parametric instabilities, if left unaddressed, present a potential threat to the stability of high-power operation.

gr-qc↗

Optimal properties of some Bayesian inferences

Relative surprise regions are shown to minimize, among Bayesian credible regions, the prior probability of covering a false value from the prior. Such regions are also shown to be unbiased in the sense that the prior probability of covering a false value is bounded above by the prior probability of covering the true value. Relative surprise regions are shown to maximize both the Bayes factor in favor of the region containing the true value and the relative belief ratio, among all credible regions with the same posterior content. Relative surprise regions emerge naturally when we consider equivalence classes of credible regions generated via reparameterizations.

math.ST↗

Thermo-optic noise in coated mirrors for high-precision optical measurements

Thermal fluctuations in the coatings used to make high-reflectors are becoming significant noise sources in precision optical measurements and are particularly relevant to advanced gravitational wave detectors. There are two recognized sources of coating thermal noise, mechanical loss and thermal dissipation. Thermal dissipation causes thermal fluctuations in the coating which produce noise via the thermo-elastic and thermo-refractive mechanisms. We treat these mechanisms coherently, give a correction for finite coating thickness, and evaluate the implications for Advanced LIGO.

gr-qc↗

Optical vernier technique for in-situ measurement of the length of long Fabry-Perot cavities

We propose a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the measurement of the separation between the carrier and a sideband resonance we determine the length of the cavity. We apply the technique to the measurement of the length of a Fabry-Perot cavity in the Caltech 40m Interferometer and discuss the accuracy of the technique.

physics.ins-det↗

From 2D conformal to 4D self-dual theories: quaternionic analyticity

It is shown that self-dual theories generalize to four dimensions both the conformal and analytic aspects of two-dimensional conformal field theories. In the harmonic space language there appear several ways to extend complex analyticity (natural in two dimensions) to quaternionic analyticity (natural in four dimensions). To be analytic, conformal transformations should be realized on $CP^3$, which appears as the coset of the complexified conformal group modulo its maximal parabolic subgroup. In this language one visualizes the twistor correspondence of Penrose and Ward and consistently formulates the analyticity of Fueter.

hep-th↗