Searcharxiv⌕ Search

arXiv subjects

M. Febbraro

Publications and source records attributed to M. Febbraro.

At least 37 records · Page 2Linked to original sources

A COHERENT constraint on leptophobic dark matter using CsI data

We use data from the COHERENT CsI[Na] scintillation detector to constrain sub-GeV leptophobic dark matter models. This detector was built to observe low-energy nuclear recoils from coherent elastic neutrino-nucleus scattering. These capabilities enable searches for dark matter particles produced at the Spallation Neutron Source mediated by a vector portal particle with masses between 2 and 400 MeV/c$^2$. No evidence for dark matter is observed and a limit on the mediator coupling to quarks is placed. This constraint improves upon previous results by two orders of magnitude. This newly explored parameter space probes the region where the dark matter relic abundance is explained by leptophobic dark matter when the mediator mass is roughly twice the dark matter mass. COHERENT sets the best constraint on leptophobic dark matter at these masses.

hep-ex↗

Monitoring the SNS basement neutron background with the MARS detector

We present the analysis and results of the first dataset collected with the MARS neutron detector deployed at the Oak Ridge National Laboratory Spallation Neutron Source (SNS) for the purpose of monitoring and characterizing the beam-related neutron (BRN) background for the COHERENT collaboration. MARS was positioned next to the COH-CsI coherent elastic neutrino-nucleus scattering detector in the SNS basement corridor. This is the basement location of closest proximity to the SNS target and thus, of highest neutrino flux, but it is also well shielded from the BRN flux by infill concrete and gravel. These data show the detector registered roughly one BRN per day. Using MARS' measured detection efficiency, the incoming BRN flux is estimated to be $1.20~\pm~0.56~\text{neutrons}/\text{m}^2/\text{MWh}$ for neutron energies above $\sim3.5$ MeV and up to a few tens of MeV. We compare our results with previous BRN measurements in the SNS basement corridor reported by other neutron detectors.

physics.ins-det↗

The COHERENT Experimental Program

The COHERENT experiment located in Neutrino Alley at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory (ORNL), has made the world's first two measurements of coherent elastic neutrino-nucleus scattering (CEvNS), on CsI and argon, using neutrinos produced at the SNS. The COHERENT collaboration continues to pursue CEvNS measurements on various targets as well as additional studies of inelastic neutrino-nucleus interactions, searches for accelerator-produced dark matter (DM) and physics beyond the Standard Model, using the uniquely high-quality and high-intensity neutrino source available at the SNS. This white paper describes primarily COHERENT's ongoing and near-future program at the SNS First Target Station (FTS). Opportunities enabled by the SNS Second Target Station (STS) for the study of neutrino physics and development of novel detector technologies are elaborated in a separate white paper.

hep-ex↗

Simulating the neutrino flux from the Spallation Neutron Source for the COHERENT experiment

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is a pulsed source of neutrons and, as a byproduct of this operation, an intense source of pulsed neutrinos via stopped-pion decay. The COHERENT collaboration uses this source to investigate coherent elastic neutrino-nucleus scattering and other physics with a suite of detectors. This work includes a description of our Geant4 simulation of neutrino production at the SNS and the flux calculation which informs the COHERENT studies. We estimate the uncertainty of this calculation at about 10% based on validation against available low-energy pion production data.

hep-ex↗

Light Output Quenching in Response to Deuterium-ions and Alpha Particles and Pulse Shape Discrimination in Deuterated Trans-stilbene

We characterized the light output response of a new 140 cm3 stilbene-d12 crystal up to 14.1 MeV neutron energies using a coincidence neutron scattering system. We also characterized its light output response to alpha particles in the 5 to 6~MeV energy range. The excellent PSD capability of the stilbene-d$_{12}$ detector allowed us to select light pulses produced by particles of increasing ionization density, namely electrons, protons, deuterium-ions, and alpha particles. The measured fast decay component of the light pulses is increasingly quenched as the ionization density of the particle in the crystal increases. Consistently with this finding, the Birks' quenching parameter of alpha particles is approximately 8.5 times larger compared to the quenching of deuterium ions, produced by neutron scattering interactions. The reported experimental characterization will allow high-fidelity modeling of the detector enabling its application for fast-neutron detection and spectroscopy in nuclear physics, radiation protection, nuclear security, and non-proliferation.

physics.ins-det↗

Development of a Pulsed VUV Light Source With Adjustable Intensity

This paper describes the development of a pulsed light source using the discharge from an electrode in a medium of various noble gases. This source can be used to aid in the characterization and testing of new vacuum-ultraviolet (VUV) sensitive light detection devices. The source includes a novel spark driver circuit, a spark chamber into which different noble gases can be introduced, and an optical attenuation cell capable of being filled with different gases to allow for the attenuation of the pulsed light down to single photon levels. We describe the construction, calibration, and characterization of this device deployed at a dedicated light detection test stand at Oak Ridge National Laboratory.

physics.ins-det↗

A D$_{2}$O detector for flux normalization of a pion decay-at-rest neutrino source

We report on the technical design and expected performance of a 592 kg heavy-water-Cherenkov detector to measure the absolute neutrino flux from the pion-decay-at-rest neutrino source at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The detector will be located roughly 20 m from the SNS target and will measure the neutrino flux with better than 5% statistical uncertainty in 2 years. This heavy-water detector will serve as the first module of a two-module detector system to ultimately measure the neutrino flux to 2-3% at both the First Target Station and the planned Second Target Station of the SNS. This detector will significantly reduce a dominant systematic uncertainty for neutrino cross-section measurements at the SNS, increasing the sensitivity of searches for new physics.

physics.ins-det↗

Characterization of stilbene-d12 for neutron spectroscopy without time of flight

We have experimentally characterized the light-output response of a deuterated trans-stilbene (stilbene-d12) crystal to quasi-monoenergetic neutrons in the 0.8 to 4.4 MeV energy range. These data allowed us to perform neutron spectroscopy measurements of a DT 14.1 MeV source and a PuBe-239 source by unfolding the impinging neutron spectrum from the measured light-output response. The stilbene-d12 outperforms a H1-stilbene of similar size when comparing the shape of the unfolded spectra and the reference ones. These results confirm the viability of non-hygroscopic stilbene-d12 crystal for direct neutron spectroscopy without need for time-of-flight measurements. This capability makes stilbene-d12 a well suited detector for fast-neutron spectroscopy in many applications including nuclear reaction studies, radiation protection, nuclear non-proliferation, and space travel.

physics.ins-det↗

Wavelength-Shifting Performance of Polyethylene Naphthalate Films in a Liquid Argon Environment

Liquid argon is commonly used as a detector medium for neutrino physics and dark matter experiments in part due to its copious scintillation light production in response to its excitation and ionization by charged particle interactions. As argon scintillation appears in the vacuum ultraviolet (VUV) regime and is difficult to detect, wavelength-shifting materials are typically used to convert VUV light to visible wavelengths more easily detectable by conventional means. In this work, we examine the wavelength-shifting and optical properties of poly(ethylene naphthalate) (PEN), a recently proposed alternative to tetraphenyl butadiene (TPB), the most widely-used wavelength-shifter in argon-based experiments. In a custom cryostat system with well-demonstrated geometric and response stability, we use 128~nm argon scintillation light to examine various PEN-including reflective samples' light-producing capabilities, and study the stability of PEN when immersed in liquid argon. The best-performing PEN-including test reflector was found to produce 34% as much visible light as a TPB-including reference sample, with widely varying levels of light production between different PEN-including test reflectors. Plausible origins for these variations, including differences in optical properties and molecular orientation, are then identified using additional measurements. Unlike TPB-coated samples, PEN-coated samples did not produce long-timescale light collection increases associated with solvation or suspension of wavelength-shifting material in bulk liquid argon.

physics.ins-det↗

First Measurement of Coherent Elastic Neutrino-Nucleus Scattering on Argon

We report the first measurement of coherent elastic neutrino-nucleus scattering (\cevns) on argon using a liquid argon detector at the Oak Ridge National Laboratory Spallation Neutron Source. Two independent analyses prefer \cevns over the background-only null hypothesis with greater than $3σ$ significance. The measured cross section, averaged over the incident neutrino flux, is (2.2 $\pm$ 0.7) $\times$10$^{-39}$ cm$^2$ -- consistent with the standard model prediction. The neutron-number dependence of this result, together with that from our previous measurement on CsI, confirms the existence of the \cevns process and provides improved constraints on non-standard neutrino interactions.

nucl-ex↗

Development of a $^{83\mathrm{m}}$Kr source for the calibration of the CENNS-10 Liquid Argon Detector

We report on the preparation of and calibration measurements with a $^{83\mathrm{m}}$Kr source for the CENNS-10 liquid argon detector. $^{83\mathrm{m}}$Kr atoms generated in the decay of a $^{83}$Rb source were introduced into the detector via injection into the Ar circulation loop. Scintillation light arising from the 9.4 keV and 32.1 keV conversion electrons in the decay of $^{83\mathrm{m}}$Kr in the detector volume were then observed. This calibration source allows the characterization of the low-energy response of the CENNS-10 detector and is applicable to other low-energy-threshold detectors. The energy resolution of the detector was measured to be 9$\%$ at the total $^{83\mathrm{m}}$Kr decay energy of 41.5 keV. We performed an analysis to separately calibrate the detector using the two conversion electrons at 9.4 keV and 32.1 keV

physics.ins-det↗

Usage of PEN as self-vetoing structural material in low background experiments

PEN is an industrial polyester plastic which has become interesting for the physics community as a new type of plastic scintillator. PEN scintillates in the blue regime, which is ideal for most photosensor devices. In addition, PEN has excellent mechanical properties and very good radiopurity has been achieved. Thus, it is an ideal candidate for active structural components in low-background experiments. One possible application are holders for germanium detectors operating in cryogenic liquids (LAr, LN2). Such structures can help to reject surface and external backgrounds, boosting the sensitivity of experiments. In this contribution, the R\&D on PEN is outlined and an evaluation of the first production of PEN structures for the LEGEND-200 experiment is reported.

physics.ins-det↗

COHERENT Collaboration data release from the first detection of coherent elastic neutrino-nucleus scattering on argon

Release of COHERENT collaboration data from the first detection of coherent elastic neutrino-nucleus scattering (CEvNS) on argon. This release corresponds with the results of "Analysis A" published in Akimov et al., arXiv:2003.10630 [nucl-ex]. Data is shared in a binned, text-based format representing both "signal" and "backgrounds" along with associated uncertainties such that the included data can be used to perform independent analyses. This document describes the contents of the data release as well as guidance on the use of the data. Included example code in C++ (ROOT) and Python show one possible use of the included data.

nucl-ex↗

Sensitivity of the COHERENT Experiment to Accelerator-Produced Dark Matter

The COHERENT experiment is well poised to test sub-GeV dark matter models using low-energy recoil detectors sensitive to coherent elastic neutrino-nucleus scattering (CEvNS) in the $π$-DAR neutrino beam produced by the Spallation Neutron Source. We show how a planned 750-kg liquid argon scintillation detector would place leading limits on scalar light dark matter models, over two orders of magnitude of dark matter mass, for dark matter particles produced through vector and leptophobic portals in the absence of other effects beyond the standard model. The characteristic timing structure of a $π$-DAR beam allows a unique opportunity for constraining systematic uncertainties on the standard model background in a time window where signal is not expected, enhancing expected sensitivity. Additionally, we discuss future prospects, further increasing the discovery potential of CEvNS detectors. Such methods would test the calculated thermal dark matter abundance for all couplings $α'\leq1$ within the vector portal model over an order of magnitude of dark matter masses.

hep-ex↗

Superallowed $0^+ \rightarrow 0^+$ $β$ decay of $T =2$ $^{20}$Mg: $Q_{\textrm{EC}}$ value and $βγ$ branching

\textbf{Background}: Superallowed $0^+ \rightarrow 0^+$ $β$ decays of isospin $T=2$ nuclides can be used to test theoretical isospin symmetry breaking corrections applied to extract the CKM matrix element $V_{ud}$ from $T = 0,1$ decays by measuring precise $ft$ values and also to search for scalar currents using the $β-ν$ angular correlation. Key ingredients include the $Q_{\textrm{EC}}$ value and branching of the superallowed transition and the half life of the parent. \textbf{Purpose}: To determine a precise experimental $Q_{\textrm{EC}}$ value for the superallowed $0^+ \rightarrow 0^+$ $β$ decay of $T=2$ $^{20}$Mg and the intensity of $^{20}$Mg $β$-delayed $γ$ rays through the isobaric analog state in $^{20}$Na. \textbf{Method}: A beam of $^{20}$Mg was produced using the in-flight method and implanted into a plastic scintillator surrounded by an array of high-purity germanium detectors used to detect $β$-delayed $γ$ rays. The high-resolution $γ$-ray spectrum was analyzed to measure the $γ$-ray energies and intensities. \textbf{Results}: The intensity of $^{20}$Mg $β$-delayed $γ$ rays through the isobaric analog state in $^{20}$Na was measured to be $(1.60 \pm 0.04_{\textrm{stat}} \pm 0.15_{\textrm{syst}} \pm 0.15_{\textrm{theo}}) \times 10^{-4}$, where the uncertainties are statistical, systematic, and theoretical, respectively. The $Q_{\textrm{EC}}$ value for the superallowed transition was determined to be $4128.7 \pm 2.2$ keV based on the measured excitation energy of $6498.4 \pm 0.2_{\textrm{stat}} \pm 0.4_{\textrm{syst}}$ keV and literature values for the ground-state masses of $^{20}$Na and $^{20}$Mg. \textbf{Conclusions}: The $β$-delayed $γ$-decay branch and $Q_{\textrm{EC}}$ value are now sufficiently precise to match or exceed the sensitivity required for current low-energy tests of the standard model.

nucl-ex↗

First Constraint on Coherent Elastic Neutrino-Nucleus Scattering in Argon

Coherent elastic neutrino-nucleus scattering (CEvNS) is the dominant neutrino scattering channel for neutrinos of energy $E_ν< 100$ MeV. We report a limit for this process using data collected in an engineering run of the 29 kg CENNS-10 liquid argon detector located 27.5 m from the Oak Ridge National Laboratory Spallation Neutron Source (SNS) Hg target with $4.2\times 10^{22}$ protons on target. The dataset yielded $< 7.4$ observed CEvNS events implying a cross section for the process, averaged over the SNS pion decay-at-rest flux, of $<3.4 \times 10^{-39}$ cm$^{2}$, a limit within twice the Standard Model prediction. This is the first limit on CEvNS from an argon nucleus and confirms the earlier CsI non-standard neutrino interaction constraints from the collaboration. This run demonstrated the feasibility of the ongoing experimental effort to detect CEvNS with liquid argon.

hep-ex↗

The Radioactive Source Calibration System of the PROSPECT Reactor Antineutrino Detector

The Precision Reactor Oscillation and Spectrum (PROSPECT) Experiment is a reactor neutrino experiment designed to search for sterile neutrinos with a mass on the order of 1 eV/c$^2$ and to measure the spectrum of electron antineutrinos from a highly-enriched $^{235}$U nuclear reactor. The PROSPECT detector consists of an 11 by 14 array of optical segments in $^{6}$Li-loaded liquid scintillator at the High Flux Isotope Reactor in Oak Ridge National Laboratory. Antineutrino events are identified via inverse beta decay and read out by photomultiplier tubes located at the ends of each segment. The detector response is characterized using a radioactive source calibration system. This paper describes the design, operation, and performance of the PROSPECT source calibration system.

physics.ins-det↗

Measurement of the Antineutrino Spectrum from $^{235}$U Fission at HFIR with PROSPECT

This Letter reports the first measurement of the $^{235}$U $\overline{ν_{e}}$ energy spectrum by PROSPECT, the Precision Reactor Oscillation and Spectrum experiment, operating 7.9m from the 85MW$_{\mathrm{th}}$ highly-enriched uranium (HEU) High Flux Isotope Reactor. With a surface-based, segmented detector, PROSPECT has observed 31678$\pm$304 (stat.) $\overline{ν_{e}}$-induced inverse beta decays (IBD), the largest sample from HEU fission to date, 99% of which are attributed to $^{235}$U. Despite broad agreement, comparison of the Huber $^{235}$U model to the measured spectrum produces a $χ^2/ndf = 51.4/31$, driven primarily by deviations in two localized energy regions. The measured $^{235}$U spectrum shape is consistent with a deviation relative to prediction equal in size to that observed at low-enriched uranium power reactors in the $\overline{ν_{e}}$ energy region of 5-7MeV.

nucl-ex↗