SearcharxivSearch

arXiv subjects

M. Fesquet

Publications and source records attributed to M. Fesquet.

8 recordsLinked to original sources

Cooling Tests of the NectarCAM camera for the Cherenkov Telescope Array

The NectarCAM is a camera proposed for the medium-sized telescopes in the framework of the Cherenkov Telescope Array (CTA), the next-generation observatory for very-high-energy gamma-ray astronomy. The cameras are designed to operate in an open environment and their mechanics must provide protection for all their components under the conditions defined for the CTA observatory. In order to operate in a stable environment and ensure the best physics performance, each NectarCAM will be enclosed in a slightly overpressurized, nearly air-tight, camera body, to prevent dust and water from entering. The total power dissipation will be ~7.7 kW for a 1855-pixel camera. The largest fraction is dissipated by the readout electronics in the modules. We present the design and implementation of the cooling system together with the test bench results obtained on the NectarCAM thermal demonstrator.

astro-ph.IM

NectarCAM : a camera for the medium size telescopes of the Cherenkov Telescope Array

NectarCAM is a camera proposed for the medium-sized telescopes of the Cherenkov Telescope Array (CTA) covering the central energy range of ~100 GeV to ~30 TeV. It has a modular design and is based on the NECTAr chip, at the heart of which is a GHz sampling Switched Capacitor Array and a 12-bit Analog to Digital converter. The camera will be equipped with 265 7-photomultiplier modules, covering a field of view of 8 degrees. Each module includes the photomultiplier bases, high voltage supply, pre-amplifier, trigger, readout and Ethernet transceiver. The recorded events last between a few nanoseconds and tens of nanoseconds. The camera trigger will be flexible so as to minimize the read-out dead-time of the NECTAr chips. NectarCAM is designed to sustain a data rate of more than 4 kHz with less than 5\% dead time. The camera concept, the design and tests of the various subcomponents and results of thermal and electrical prototypes are presented. The design includes the mechanical structure, cooling of the electronics, read-out, clock distribution, slow control, data-acquisition, triggering, monitoring and services.

astro-ph.IM

The NectarCAM camera project

In the framework of the next generation of Cherenkov telescopes, the Cherenkov Telescope Array (CTA), NectarCAM is a camera designed for the medium size telescopes covering the central energy range of 100 GeV to 30 TeV. NectarCAM will be finely pixelated (~ 1800 pixels for a 8 degree field of view, FoV) in order to image atmospheric Cherenkov showers by measuring the charge deposited within a few nanoseconds time-window. It will have additional features like the capacity to record the full waveform with GHz sampling for every pixel and to measure event times with nanosecond accuracy. An array of a few tens of medium size telescopes, equipped with NectarCAMs, will achieve up to a factor of ten improvement in sensitivity over existing instruments in the energy range of 100 GeV to 10 TeV. The camera is made of roughly 250 independent read-out modules, each composed of seven photo-multipliers, with their associated high voltage base and control, a read-out board and a multi-service backplane board. The read-out boards use NECTAr (New Electronics for the Cherenkov Telescope Array) ASICs which have the dual functionality of analogue memories and Analogue to Digital Converter (ADC). The camera trigger to be used will be flexible so as to minimize the read-out dead-time of the NECTAr chips. We present the camera concept and the design and tests of the various subcomponents. The design includes the mechanical parts, the cooling of the electronics, the readout, the data acquisition, the trigger, the monitoring and services.

astro-ph.IM

The Wide-Field X and Gamma-Ray Telescope ECLAIRs aboard the Gamma-Ray Burst Multi-Wavelength Space Mission SVOM

The X and Gamma-ray telescope ECLAIRs is foreseen to be launched on a low Earth orbit (h=630 km, i=30 degrees) aboard the SVOM satellite (Space-based multi-band astronomical Variable Objects Monitor), a French-Chinese mission with Italian contribution. Observations are expected to start in 2013. It has been designed to detect and localize Gamma-Ray Bursts (GRBs) or persistent sources of the sky, thanks to its wide field of view (about 2 sr) and its remarkable sensitivity in the 4-250 keV energy range, with enhanced imaging sensitivity in the 4-70 keV energy band. These characteristics are well suited to detect highly redshifted GRBs, and consequently to provide fast and accurate triggers to other onboard or ground-based instruments able to follow-up the detected events in a very short time from the optical wavelength bands up to the few MeV Gamma-Ray domain.

astro-ph

Identification of backgrounds in the EDELWEISS-I dark matter search experiment

This paper presents our interpretation and understanding of the different backgrounds in the EDELWEISS-I data sets. We analyze in detail the several populations observed, which include gammas, alphas, neutrons, thermal sensor events and surface events, and try to combine all data sets to provide a coherent picture of the nature and localisation of the background sources. In light of this interpretation, we draw conclusions regarding the background suppression scheme for the EDELWEISS-II phase.

astro-ph

Measurement of the response of heat-and-ionization germanium detectors to nuclear recoils

The heat quenching factor Q' (the ratio of the heat signals produced by nuclear and electron recoils of equal energy) of the heat-and-ionization germanium bolometers used by the EDELWEISS collaboration has been measured. It is explained how this factor affects the energy scale and the effective quenching factor observed in calibrations with neutron sources. This effective quenching effect is found to be equal to Q/Q', where Q is the quenching factor of the ionization yield. To measure Q', a precise EDELWEISS measurement of Q/Q' is combined with values of Q obtained from a review of all available measurements of this quantity in tagged neutron beam experiments. The systematic uncertainties associated with this method to evaluate Q' are discussed in detail. For recoil energies between 20 and 100 keV, the resulting heat quenching factor is Q' = 0.91+-0.03+-0.04, where the two errors are the contributions from the Q and Q/Q' measurements, respectively. The present compilation of Q values and evaluation of Q' represent one of the most precise determinations of the absolute energy scale for any detector used in direct searches for dark matter.

astro-ph

Final results of the EDELWEISS-I dark matter search with cryogenic heat-and-ionization Ge detectors

The final results of the EDELWEISS-I dark matter search using cryogenic heat-and-ionization Ge detectors are presented. The final data sample corresponds to an increase by a factor five in exposure relative to the previously published results. A recoil energy threshold of 13 keV or better was achieved with three 320g detectors working simultaneously over four months of stable operation. Limits on the spin-independent cross-section for the scattering of a WIMP on a nucleon are derived from an accumulated fiducial exposure of 62 kg.d.

astro-ph

Sensitivity of the EDELWEISS WIMP search to spin-dependent interactions

The EDELWEISS collaboration is searching for WIMP dark matter using natural Ge cryogenic detectors. The whole data set of the first phase of the experiment contains a fiducial exposure of 4.8 kg.day on Ge-73, the naturally present (7.8%), high-spin Ge isotope. The sensitivity of the experiment to the spin-dependent WIMP-nucleon interactions is evaluated using the model-independent framework proposed by Tovey et al.

astro-ph