SearcharxivSearch

arXiv subjects

M. Friedl

Publications and source records attributed to M. Friedl.

At least 19 recordsLinked to original sources

Development and Commissioning of the Cryogenic Target Detectors for the Technical Run of the NUCLEUS Experiment

The NUCLEUS experiment aims to study coherent elastic neutrino-nucleus scattering (CE$\nu$NS) of reactor electron antineutrinos at the Chooz nuclear power plant in France. In this work, the cryogenic target-detector module for the NUCLEUS Technical Run was developed and commissioned at the Technical University of Munich. The module comprises four gram-scale CaWO$_4$ detectors, each equipped with two Transition Edge Sensors (TES), providing a total target mass of 6.96 g. We present the design, integration, detector characterization, and X-ray-based energy calibration of these detectors. Across six characterized detectors, a mean baseline resolution of $\overline{\sigma}_{\mathrm{BL}} = (2.79 \pm 0.60)\,\mathrm{eV}$ was achieved. The best-performing detector reached $\sigma_{\mathrm{BL}} = (2.16 \pm 0.02_{\mathrm{stat}})\,\mathrm{eV}$, surpassing the design goal by a factor of two and representing a state-of-the-art result for a cryogenic CaWO$_4$ detector. The target detector module was successfully operated simultaneously with the surrounding Cryogenic Outer Veto, which consists of six kg-scale Ge detectors for background discrimination, showing no measurable cross-talk. These results demonstrate the readiness of the target-detector system for the NUCLEUS Technical Run at Chooz and mark a key milestone in the development of cryogenic detectors for reactor-CE$\nu$NS measurements.

physics.ins-det

Optimization studies of silicon remoTES cryogenic calorimeters

The remoTES design, developed within the COSINUS experiment, enables a broader range of materials to be operated as cryogenic calorimeters read out with Transition Edge Sensors (TESs). In this configuration, the TES is fabricated onto a separate chip and thermally coupled to the absorber via a gold (Au) link. The remoTES concept has been successfully tested on various target materials. To further enhance detector performance and to fully exploit the advantages of the remote coupling design a series of optimization studies has been conducted using silicon (Si) absorbers as benchmark. This work presents an evaluation of several measurements aimed at reducing the thermal boundary resistance and enhancing signal transmission across Si remoTES interfaces, specifically from the absorber to the phonon collector and from the phonon collector to the TES. By testing a new Au link design and three distinct phonon collector configurations, Au, copper, and aluminum (Al)/Au, we achieved a baseline resolution of (21.5 +/- 0.3)eV using the Al/Au phonon collector.

physics.ins-det

Development for the Belle II vertex detector upgrade with depleted monolithic active pixel sensors

The vertex detector upgrade project for the Belle II experiment, based on CMOS depleted monolithic active pixel sensor technology, is planned to be carried out in conjunction with the major modification of the interaction region of the SuperKEKB collider during Long Shutdown 2 from 2032 to 2034. The MAPS sensor, named OBELIX currently under development, is derived from the successor to TJ-Monopix2, with modifications implemented to ensure compatibility with the Belle II trigger system. The new vertex detector consists of two layers of four self-supported consecutive OBELIX sensors, and three layers of discrete OBELIX sensors mounted on mechanical support structures with readout flex circuits attached to the sensors. The detector is arranged cylindrically around the beam pipe at radii ranging from 14 mm to 140 mm. The minimization of the material budget is required in order to enhance physics performance. We present an overview of the project and its latest developments, with particular emphasis on the development of low-material-budget flex circuits employing aluminum conductors.

physics.ins-det

Application of exhaustive simulation flow for advanced performance prediction of monolithic active pixel sensors

Monolithic active pixel sensor (MAPS) developments have pushed the detection performance in various directions, especially relative to timing where nanosecond-level precision is now considered. This evolution calls for a simultaneous upgrade of the simulation tools. We have developed a simulation flow that covers steps from the signal creation in the sensitive volume to the output of the pixel digital logic that performs the time-of-arrival and time-over-threshold (ToA/ToT) measurements. This approach adds several new features to the traditional use the of the TCAD - Allpix Squared duo, among which : the integration of the pixel wells from the layout in order to precisely describe the pixel key characteristics such as leakage and punch-through currents and the coupling of Monte Carlo simulations (Allpix Squared) with high precision electrical simulations (SPICE). The first (Allpix Squared) for the precise description of the current induced at the collection electrode and the second (SPICE) to guarantee high precision simulation of the front-end electronics using realistic signal events. Irradiation is also modeled, both from the charge propagation side (charge trapping) and from the front-end response side (high input signal discharge). We have applied this methodology to the MAPS developed in the context of the Belle II vertex detector upgrade. In this contribution, we detail the key features of the exhaustive simulation flow, present the outcome of the comparison with the TJ-Monopix2 measurements and discuss the interest of the methodology for the development of modern MAPS.

physics.ins-det

Sensitivity enhancement techniques for cryogenic calorimeters in the NUCLEUS experiment

Phonon-mediated cryogenic calorimeters find application in rare event searches due to their intrinsically low energy threshold. Achieving the best sensitivity for this kind of detectors is crucial for signal identification, leading to various optimization techniques. In this work, we present two complementary methods to increase the sensitivity of cryogenic detectors read out by transition-edge sensors, developed and tested in the context of the NUCLEUS experiment. The first procedure maps the signal-to-noise ratio of the device across a wide range of operating points, to identify the configuration with maximal sensitivity to be used during data taking. The second method exploits the double readout of the detector, combining the information on different channels with a two-dimensional optimum filter analysis that effectively lowers the energy threshold. With both techniques at the same time, we obtained a baseline resolution of 2.94 $\pm$ 0.05 (stat) eV using a CaWO4 based detector, achieving a promising result in view of the first run of NUCLEUS at the experimental site.

physics.ins-det

Prospect of the NUCLEUS Experiment at Chooz for Coherent Elastic Neutrino-Nucleus Scattering and New Physics Searches

The NUCLEUS experiment aims to measure coherent elastic neutrino-nucleus scattering (CE$\nu$NS) at unprecedentedly low nuclear recoil energies using gram-scale cryogenic calorimeters operated at the Chooz nuclear power plant in France. Access to recoil energies at the $\mathcal{O}(10~\mathrm{eV})$ scale enables CE$\nu$NS studies at extremely low momentum transfer and provides enhanced sensitivity to new physics. In this work, we present sensitivity projections for the upcoming NUCLEUS technical and physics runs, incorporating a data-driven treatment of the low-energy excess (LEE) observed during commissioning. We develop a likelihood framework that exploits reactor-power variation to disentangle signal and background in a low signal-to-background regime and to assess the impact of the dominant systematic uncertainties. For the Technical Run with a 7 g CaWO$_4$ target, we find competitive sensitivity to several scenarios beyond the Standard Model, which do not require a CE$\nu$NS observation. For the Physics Run, assuming complete suppression of the LEE, we project a 4.7 $\sigma$ observation of CE$\nu$NS with a statistical precision of about 20 % in 1 year, enabling a determination of the weak mixing angle at the lowest momentum transfer probed to date with CE$\nu$NS and leading CE$\nu$NS-based constraints on the neutrino charge radius and new mediator models.

hep-ex

Cosmic Ray Boosted Dark Matter in COSINUS: Modeling and Constraints

Direct detection of nuclear recoils due to sub-GeV dark matter is challenging because of the small kinetic energy of the light dark matter particles. Although limits down to a few hundred MeV have been reached using specially designed low threshold detectors, further improvements are now constrained more by background event rates than by energy thresholds. However, constraints down to sub-MeV dark matter masses can still be obtained through the boosted dark matter framework. In this scenario, high-energy cosmic rays or neutrinos scatter off dark matter particles, imparting additional kinetic energy and boosting them beyond the typical velocities expected from the non-relativistic dark matter halo. These boosted dark matter particles can then be detected even by experiments with higher energy thresholds. In this work, we present a catalog of dark matter - nucleon scattering cross sections corresponding to a heavy mediator limit for spin zero, one half and one dark matter and for scalar and vector mediators with even or odd parity. Based on these results, we present projected constraints on the dark matter - nucleon cross section for the COSINUS experiment, assuming an exposure of 100 kg d, demonstrating the potential sensitivity to sub-GeV boosted dark matter.

hep-ph

Characterization of the Low Energy Excess using a NUCLEUS Al$_{2}$O$_{3}$ detector

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos using low-threshold, gram-scale cryogenic calorimeters. Similar to other low-threshold experiments, NUCLEUS observes a sharp rise in the event rate below a few hundred eV, referred to as the low energy excess (LEE), whose origin remains yet unidentified. Building on results from the NUCLEUS testing and commissioning at the Technical University of Munich and from previous characterization campaigns, we present a comprehensive study of the background rate measured with a sapphire detector equipped with two transition-edge sensors under various experimental conditions. We find no evidence for a dependence of the LEE rate on the particle background level, whereas the results indicate that slower cooling-down procedures lead to lower initial LEE rates. The behavior of the LEE rate during the same cooldown is comparable across the measurements and is best described by a power law with a common exponent across datasets of $(-0.59 \pm 0.06)$, when time is expressed from the moment the detector reaches the 4 K temperature. These findings provide valuable guidance for future LEE mitigation strategies in the NUCLEUS experiment.

physics.ins-det

Defect Formation in NaI Crystals: A Novel Pathway to Dark Matter Detection

Sodium iodide (NaI) is a widely used scintillator in direct dark matter searches. In particular, NaI-based cryogenic scintillating calorimeters have emerged as promising candidates, like in the COSINUS experiment, for testing the annually modulating signal reported by DAMA/LIBRA. In this study, we investigate defect formation within NaI crystals and its impact on the dark matter detection signal. Using molecular dynamics simulations and density functional theory techniques, we simulate a DM particle collision on an NaI crystal, focusing on the possible defects formation and their structural and electronic properties. Our analysis includes a detailed study of the electronic states associated with the interstitial atoms and vacancies, the energetic cost of defect formation, and the anisotropic threshold displacement energy. Finally, we highlight the potential to exploit dark matter-induced defects as a novel detection channel, enabled by the introduction of new states within the electronic band gap.

hep-ph

Observation of two nuclear recoil peaks induced by neutron capture on Al2O3

We report the observation of two nuclear recoil peaks induced by neutron capture on aluminum in a cryogenic Al$_2$O$_3$ detector developed by the NUCLEUS collaboration for the detection of reactor neutrinos via coherent elastic neutrino-nucleus (CEvNS) process. Data collected at the Technical University of Munich in 2024 with a $^{252}$Cf source reveal a main recoil line at 1145 eV from single-$\gamma$ de-excitation of $^{28}$Al and a newly observed structure near 575 eV originating from several two-$\gamma$ cascades. The latter constitutes the first direct measurement of a nuclear recoil line induced by multi-$\gamma$ cascades. It is predicted by our simulations when the recoiling nucleus has time to stop before the emission of the next $\gamma$-ray in the cascade. These results demonstrate the potential performance of the CRAB (Calibration Recoil for Accurate Bolometry) method for in situ nuclear recoil calibration and highlight the importance of accurately modeling recoil stopping and nuclear de-excitation times in cryogenic detectors of CEvNS and dark matter interactions.

physics.ins-det

Quenching factors for Na recoils as a function of Tl dopant concentrations in NaI(Tl) crystals

Thallium-doped sodium iodide (NaI(Tl)) scintillation detectors play an important role in the field of direct dark matter (DM) searches. The DAMA/LIBRA experiment stands out for its reported observation of an annually modulating DM-like signal, which is in direct contrast with other results. To accurately calibrate the energies of nuclear recoil signals with electron recoils, precise measurements of the quenching factor of the NaI(Tl) crystals are essential, as the two processes have different scintillation light yield. In this article, we present results of a systematic study carried out by the COSINUS collaboration and Duke University to measure the quenching factor of sodium (Na) recoils as a function of nuclear recoil energy and for differing Thallium (Tl) dopant concentrations in the bulk crystal. Five ultrapure NaI(Tl) crystals, manufactured by the Shanghai Institute for Ceramics, were irradiated with a quasi-monoenergetic neutron beam at the Triangle Universities Nuclear Laboratory, North Carolina, USA. The quenching factor for low nuclear recoil energies of 5-26keV$_{nr}$ was extracted for all 5 crystals. A Tl-dependence could be deduced with a proportional response calibration schema using a $^{241}$Am source. However, this effect was not observed when using a low-energy calibration line from $^{133}$Ba.

physics.ins-det

Radiation damage study of Belle II silicon strip sensors with 90 MeV electron irradiation

The silicon strip sensors of the Belle II silicon vertex detector were irradiated with 90 MeV electron beams up to an equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. We measure changes in sensor properties induced by radiation damage in the semiconductor bulk. Electrons around this energy are a major source of beam-induced background during Belle II operation. We discuss observed changes in full depletion voltage, sensor leakage current, noise, and charge collection. The sensor bulk type inverts at an equivalent 1-MeV-neutron fluence of $6.0\times 10^{12}~{\rm n}_{\rm eq}/{\rm cm^2}$. The leakage current increases proportionally to the radiation dose. We determine a damage constant of $3.9 \times 10^{-17}$ A/cm at 17 C$^\circ$ immediately after irradiation, which drops significantly to approximately 40% of the initial value in 200 hours, then stabilizes to approximately 30% of the initial value in 1000 hours. We measure sensor noise and signal charge for a sensor irradiated with the equivalent 1-MeV-neutron fluence of $3.0\times 10^{13}~{\rm n}_{\rm eq}/{\rm cm^2}$. Noise increases by approximately 44% after irradiation, while signal charge does not change significantly when a sufficiently high bias voltage is applied.

physics.ins-det

Particle background characterization and prediction for the NUCLEUS reactor CE$\nu$NS experiment

NUCLEUS is a cryogenic detection experiment which aims to measure Coherent Elastic Neutrino-Nucleus Scattering (CE$\nu$NS) and to search for new physics at the Chooz nuclear power plant in France. This article reports on the prediction of particle-induced backgrounds, especially focusing on the sub-keV energy range, which is a poorly known region where most of the CE$\nu$NS signal from reactor antineutrinos is expected. Together with measurements of the environmental background radiations at the experimental site, extensive Monte Carlo simulations based on the Geant4 package were run both to optimize the experimental setup for background reduction and to estimate the residual rates arising from different contributions such as cosmic ray-induced radiations, environmental gammas and material radioactivity. The NUCLEUS experimental setup is predicted to achieve a total rejection power of more than two orders of magnitude, leaving a residual background component which is strongly dominated by cosmic ray-induced neutrons. In the CE$\nu$NS signal region of interest between 10 and 100 eV, a total particle background rate of $\sim$ 250 d$^{-1}$kg$^{-1}$keV$^{-1}$ is expected in the CaWO$_4$ target detectors. This corresponds to a signal-to-background ratio $\gtrsim$ 1, and therefore meets the required specifications in terms of particle background rejection for the detection of reactor antineutrinos through CE$\nu$NS.

physics.ins-det

Commissioning of the NUCLEUS Experiment at the Technical University of Munich

The NUCLEUS experiment aims to detect coherent elastic neutrino-nucleus scattering of reactor antineutrinos on CaWO$_4$ targets in the fully coherent regime, using gram-scale cryogenic calorimeters. The experimental apparatus will be installed at the Chooz nuclear power plant in France, in the vicinity of two 4.25 GW$_{\text{th}}$ reactor cores. This work presents results from the commissioning of an essential version of the experiment at the shallow Underground Laboratory of the Technical University of Munich. For the first time, two cryogenic target detectors were tested alongside active and passive shielding systems. Over a period of two months all detector subsystems were operated with stable performance. Background measurements were conducted, providing important benchmarks for the modeling of background sources at the reactor site. Finally, we present ongoing efforts to upgrade the detector systems in preparation for a technical run at Chooz in 2026, and highlight the remaining challenges to achieving neutrino detection.

hep-ex

COSINUS -- a model-independent challenge of the DAMA/LIBRA dark matter claim with cryogenic NaI detectors operated in a new low-background facility

Low-temperature detectors are a powerful technology for dark matter search, offering excellent energy resolution and low energy thresholds. COSINUS is the only experiment that combines scintillating sodium iodide (NaI) crystals with an additional phonon readout at cryogenic temperatures, using superconducting sensors (remoTES), alongside the conventional scintillation light signal. Via the simultaneous phonon and scintillation light detection, a unique event-by-event particle identification is enabled. This dual-channel approach allows for a model-independent cross-check of the long-standing DAMA/LIBRA signal with a moderate exposure of a few hundred kg d, while completely avoiding key systematic uncertainties inherent to scintillation-only NaI-based searches. COSINUS built and commissioned a dedicated low-background cryogenic facility at the LNGS underground laboratories. Data taking with eight NaI detector modules (COSINUS1$\pi$ Run1) is planned to begin in late 2025.

physics.ins-det

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

The CRAB facility at the TU Wien TRIGA reactor: status and related physics program

The CRAB (Calibrated nuclear Recoils for Accurate Bolometry) project aims to precisely characterize the response of cryogenic detectors to sub-keV nuclear recoils of direct interest for coherent neutrino-nucleus scattering and dark matter search experiments. The CRAB method relies on the radiative capture of thermal neutrons in the target detector, resulting in a nuclear recoil with a well-defined energy. We present a new experimental setup installed at the TRIGA Mark-II reactor at Atominstitut (Vienna), providing a low intensity beam of thermal neutrons sent to the target cryogenic detector mounted inside a wet dilution refrigerator Kelvinox 100. A crown of BaF$_2$ detectors installed outside the dewar enables coincident detection of the high-energy $\gamma$ escaping the target crystal after neutron capture. After the presentation of all components of the setup we report the analysis of first commissioning data with a CaWO$_4$ detector of the \NUCLEUS experiment. They show stable operation of the cryostat and detectors on a week-scale. Due to an energy resolution currently limited to 20 eV we use neutron beam induced events at high energy, in the 10 to 100 keV range, to demonstrate the excellent agreement between the data and simulation and the accurate understanding of external background. Thanks to these data we also propose an updated decay scheme of the low-lying excited states of $^{187}$W. Finally, we present the first evidence of neutron-capture induced coincidences between $\gamma$-detectors and a cryogenic detector. These promising results pave the way for an extensive physics program with various detector materials, like CaWO$_4$, Al$_2$O$_3$, Ge and Si.

physics.ins-det

COSINUS model-independent sensitivity to the DAMA/LIBRA dark matter signal

COSINUS is a dark matter direct detection experiment using NaI crystals as cryogenic scintillating calorimeters. If no signal is observed, this will constrain the dark matter scattering rate in sodium iodide. We investigate how this constraint can be used to infer that the annual modulation signal observed in the DAMA/LIBRA experiment cannot originate from dark matter nuclear recoil events, independently of the dark matter model. We achieve this by unfolding the DAMA modulation spectrum to obtain the implied unquenched nuclear recoil spectrum, which we then compare to the expected COSINUS sensitivity. We find that assuming zero background in the signal region, a 1$\sigma$, 2$\sigma$ or 3$\sigma$ confidence limit exclusion can be obtained with 57, 130 or 250 kg day of exposure, respectively. A simple background model indicates that in the presence of background, the exposure requirements may increase by $\sim30\%$.

hep-ph