SearcharxivSearch

arXiv subjects

M. Frutti

Publications and source records attributed to M. Frutti.

14 recordsLinked to original sources

An updated list of AGILE bright gamma-ray sources and their variability in pointing mode

We present a variability study of a sample of bright gamma-ray (30 MeV -- 50 GeV) sources. This sample is an extension of the first AGILE catalogue of gamma-ray sources (1AGL), obtained using the complete set of AGILE observations in pointing mode performed during a 2.3 year period from July 9, 2007 until October 30, 2009. The dataset of AGILE pointed observations covers a long time interval and its gamma-ray data archive is useful for monitoring studies of medium-to-high brightness gamma-ray sources. In the analysis reported here, we used data obtained with an improved event filter that covers a wider field of view, on a much larger (about 27.5 months) dataset, integrating data on observation block time scales, which mostly range from a few days to thirty days. The data processing resulted in a better characterized source list than 1AGL was, and includes 54 sources, 7 of which are new high galactic latitude (|BII| >= 5) sources, 8 are new sources on the galactic plane, and 20 sources from the previous catalogue with revised positions. Eight 1AGL sources (2 high-latitude and 6 on the galactic plane) were not detected in the final processing either because of low OB exposure and/or due to their position in complex galactic regions. We report the results in a catalogue of all the detections obtained in each single OB, including the variability results for each of these sources. In particular, we found that 12 sources out of 42 or 11 out of 53 are variable, depending on the variability index used, where 42 and 53 are the number of sources for which these indices could be calculated. Seven of the 11 variable sources are blazars, the others are Crab pulsar+nebula, LS I +61°303, Cyg X-3, and 1AGLR J2021+4030.

astro-ph.HE

AGILE detection of extreme gamma-ray activity from the blazar PKS 1510-089 during March 2009. Multifrequency analysis

We report on the extreme gamma-ray activity from the FSRQ PKS 1510-089 observed by AGILE in March 2009. In the same period a radio-to-optical monitoring of the source was provided by the GASP-WEBT and REM. Moreover, several Swift ToO observations were triggered, adding important information on the source behaviour from optical/UV to hard X-rays. We paid particular attention to the calibration of the Swift/UVOT data to make it suitable to the blazars spectra. Simultaneous observations from radio to gamma rays allowed us to study in detail the correlation among the emission variability at different frequencies and to investigate the mechanisms at work. In the period 9-30 March 2009, AGILE detected an average gamma-ray flux of (311+/-21)x10^-8 ph cm^-2 s^-1 for E>100 MeV, and a peak level of (702+/-131)x10^-8 ph cm^-2 s^-1 on daily integration. The gamma-ray activity occurred during a period of increasing activity from near-IR to UV, with a flaring episode detected on 26-27 March 2009, suggesting that a single mechanism is responsible for the flux enhancement observed from near-IR to UV. By contrast, Swift/XRT observations seem to show no clear correlation of the X-ray fluxes with the optical and gamma-ray ones. However, the X-ray observations show a harder photon index (1.3-1.6) with respect to most FSRQs and a hint of harder-when-brighter behaviour, indicating the possible presence of a second emission component at soft X-ray energies. Moreover, the broad band spectrum from radio-to-UV confirmed the evidence of thermal features in the optical/UV spectrum of PKS 1510-089 also during high gamma-ray state. On the other hand, during 25-26 March 2009 a flat spectrum in the optical/UV energy band was observed, suggesting an important contribution of the synchrotron emission in this part of the spectrum during the brightest gamma-ray flare, therefore a significant shift of the synchrotron peak.

astro-ph.HE

Monitoring the hard X-ray sky with SuperAGILE

SuperAGILE is the hard X-ray monitor of the AGILE gamma ray mission, in orbit since 23$^{rd}$ April 2007. It is an imaging experiment based on a set of four independent silicon strip detectors, equipped with one-dimensional coded masks, operating in the nominal energy range 18-60 keV. The main goal of SuperAGILE is the observation of cosmic sources simultaneously with the main gamma-ray AGILE experiment, the Gamma Ray Imaging Detector (GRID). Given its $\sim$steradian-wide field of view and its $\sim$15 mCrab day-sensitivity, SuperAGILE is also well suited for the long-term monitoring of Galactic compact objects and the detection of bright transients. The SuperAGILE detector properties and design allow for a 6 arcmin angular resolution in each of the two independent orthogonal projections of the celestial coordinates. Photon by photon data are continuously available by the experiment telemetry, and are used to derive images and fluxes of individual sources, with integration times depending on the source intensity and position in the field of view. In this paper we report on the main scientific results achieved by SuperAGILE over its first two years in orbit, until April 2009.

astro-ph.IM

Multiwavelength observations of 3C 454.3 II. The AGILE 2007 December campaign

We report on the second AGILE multiwavelength campaign of the blazar 3C 454.3 during the first half of December 2007. This campaign involved AGILE, Spitzer, Swift,Suzaku,the WEBT consortium,the REM and MITSuME telescopes,offering a broad band coverage that allowed for a simultaneous sampling of the synchrotron and inverse Compton (IC) emissions.The 2-week AGILE monitoring was accompanied by radio to optical monitoring by WEBT and REM and by sparse observations in mid-Infrared and soft/hard X-ray energy bands performed by means of Target of Opportunity observations by Spitzer, Swift and Suzaku, respectively.The source was detected with an average flux of~250x10^{-8}ph cm^-2s^-1 above 100 MeV,typical of its flaring states.The simultaneous optical and gamma-ray monitoring allowed us to study the time-lag associated with the variability in the two energy bands, resulting in a possible ~1-day delay of the gamma-ray emission with respect to the optical one. From the simultaneous optical and gamma-ray fast flare detected on December 12, we can constrain the delay between the gamma-ray and optical emissions within 12 hours. Moreover, we obtain three Spectral Energy Distributions (SEDs) with simultaneous data for 2007 December 5, 13, 15, characterized by the widest multifrequency coverage. We found that a model with an external Compton on seed photons by a standard disk and reprocessed by the Broad Line Regions does not describe in a satisfactory way the SEDs of 2007 December 5, 13 and 15. An additional contribution, possibly from the hot corona with T=10^6 K surrounding the jet, is required to account simultaneously for the softness of the synchrotron and the hardness of the inverse Compton emissions during those epochs.

astro-ph.CO

First AGILE Catalog of High Confidence Gamma-Ray Sources

We present the first catalog of high-confidence gamma-ray sources detected by the AGILE satellite during observations performed from July 9, 2007 to June 30, 2008. Catalogued sources are detected by merging all the available data over the entire time period. AGILE, launched in April 2007, is an ASI mission devoted to gamma-ray observations in the 30 MeV - 50 GeV energy range, with simultaneous X-ray imaging capability in the 18-60 keV band. This catalog is based on Gamma-Ray Imaging Detector (GRID) data for energies greater than 100 MeV. For the first AGILE catalog we adopted a conservative analysis, with a high-quality event filter optimized to select gamma-ray events within the central zone of the instrument Field of View (radius of 40 degrees). This is a significance-limited (4 sigma) catalog, and it is not a complete flux-limited sample due to the non-uniform first year AGILE sky coverage. The catalog includes 47 sources, 21 of which are associated with confirmed or candidate pulsars, 13 with Blazars (7 FSRQ, 4 BL Lacs, 2 unknown type), 2 with HMXRBs, 2 with SNRs, 1 with a colliding-wind binary system, 8 with unidentified sources.

astro-ph.HE

Gamma-ray burst detection with the AGILE mini-calorimeter

The Mini-Calorimeter (MCAL) instrument on-board the AGILE satellite is a non-imaging gamma-ray scintillation detector sensitive in the 300keV-100MeV energy range with a total on-axis geometrical area of 1400cm^2. Gamma-Ray Bursts (GRBs) are one of the main scientific targets of the AGILE mission and the MCAL design as an independent self-triggering detector makes it a valuable all-sky monitor for GRBs. Furthermore MCAL is one of the very few operative instruments with microsecond timing capabilities in the MeV range. In this paper the results of GRB detections with MCAL after one year of operation in space are presented and discussed. A flexible trigger logic implemented in the AGILE payload data-handling unit allows the on-board detection of GRBs. For triggered events, energy and timing information are sent to telemetry on a photon-by-photon basis, so that energy and time binning are limited by counting statistics only. When the trigger logic is not active, GRBs can be detected offline in ratemeter data, although with worse energy and time resolution. Between the end of June 2007 and June 2008 MCAL detected 51 GRBs, with a detection rate of about 1 GRB/week, plus several other events at a few milliseconds timescales. Since February 2008 the on-board trigger logic has been fully active. Comparison of MCAL detected events and data provided by other space instruments confirms the sensitivity and effective area estimations. MCAL also joined the 3rd Inter-Planetary Network, to contribute to GRB localization by means of triangulation.

astro-ph

AGILE detection of variable gamma-ray activity from the blazar S5 0716+714 in September-October 2007

We report the gamma-ray activity from the intermediate BL Lac S5 0716+714 during observations acquired by the AGILE satellite in September and October 2007. These detections of activity were contemporaneous with a period of intense optical activity, which was monitored by GASP-WEBT. This simultaneous optical and gamma-ray coverage allows us to study in detail the light curves, time lags, gamma-ray photon spectrum, and Spectral Energy Distributions (SEDs) during different states of activity. AGILE observed the source with its two co-aligned imagers, the Gamma-Ray Imaging Detector (GRID) and the hard X-ray imager (Super-AGILE), which are sensitive to the 30 MeV-50 GeV and 18-60 keV energy ranges, respectively. Observations were completed in two different periods, the first between 2007 September 4-23, and the second between 2007 October 24-November 1. Over the period 2007 September 7-12, AGILE detected gamma-ray emission from the source at a significance level of 9.6-sigma with an average flux (E>100 MeV) of (97 +/- 15) x 10^{-8} photons cm^{-2} s^{-1}, which increased by a factor of at least four within three days. No emission was detected by Super-AGILE for the energy range 18-60 keV to a 3-sigma upper limit of 10 mCrab in 335 ksec. In October 2007, AGILE repointed toward S5 0716+714 following an intense optical flare, measuring an average flux of (47 +/- 11) x 10^{-8} photons cm^{-2} s^{-1} at a significance level of 6.0-sigma. The gamma-ray flux of S5 0716+714 detected by AGILE is the highest ever detected for this blazar and one of the most intense gamma-ray fluxes detected from a BL Lac object. The SED of mid-September appears to be consistent with the synchrotron self-Compton (SSC) emission model, but only by including two SSC components of different variabilities.

astro-ph

Design of a CZT Gamma-Camera for GRB and Fast Transient Follow-up: a Wide-Field-Monitor for the EDGE Mission

The success of the SWIFT/BAT and INTEGRAL missions has definitely opened a new window for follow-up and deep study of the transient gamma-ray sky. This now appears as the access key to important progresses in the area of cosmological research and deep understanding of the physics of compact objects. To detect in near real-time explosive events like Gamma-Ray bursts, thermonuclear flashes from Neutron Stars and other types of X-ray outbursts we have developed a concept for a wide-field gamma-ray coded mask instrument working in the range 8-200 keV, having a sensitivity of 0.4 ph cm-2 s-1 in 1s (15-150 keV) and arcmin location accuracy over a sky region as wide as 3sr. This scientific requirement can be achieved by means of two large area, high spatial resolution CZT detection planes made of arrays of relatively large (~1cm2) crystals, which are in turn read out as matrices of smaller pixels. To achieve such a wide Field-Of-View the two units can be placed at the sides of a S/C platform serving a payload with a complex of powerful X-ray instruments, as designed for the EDGE mission. The two units will be equipped with powerful signal read out system and data handling electronics, providing accurate on-board reconstruction of the source positions for fast, autonomous target acquisition by the X-ray telescopes.

astro-ph

Science with the new generation high energy gamma- ray experiments

This Conference is the fifth of a series of Workshops on High Energy Gamma- ray Experiments, following the Conferences held in Perugia 2003, Bari 2004, Cividale del Friuli 2005, Elba Island 2006. This year the focus was on the use of gamma-ray to study the Dark Matter component of the Universe, the origin and propagation of Cosmic Rays, Extra Large Spatial Dimensions and Tests of Lorentz Invariance.

astro-ph

Low energy polarization sensitivity of the Gas Pixel Detector

An X-ray photoelectric polarimeter based on the Gas Pixel Detector has been proposed to be included in many upcoming space missions to fill the gap of about 30 years from the first (and to date only) positive measurement of polarized X-ray emission from an astrophysical source. The estimated sensitivity of the current prototype peaks at an energy of about 3 keV, but the lack of readily available polarized sources in this energy range has prevented the measurement of detector polarimetric performances. In this paper we present the measurement of the Gas Pixel Detector polarimetric sensitivity at energies of a few keV and the new, light, compact and transportable polarized source that was devised and built to this aim. Polarized photons are produced, from unpolarized radiation generated with an X-ray tube, by means of Bragg diffraction at nearly 45 degrees. The employment of mosaic graphite and flat aluminum crystals allow the production of nearly completely polarized photons at 2.6, 3.7 and 5.2 keV from the diffraction of unpolarized continuum or line emission. The measured modulation factor of the Gas Pixel Detector at these energies is in good agreement with the estimates derived from a Monte Carlo software, which was up to now employed for driving the development of the instrument and for estimating its low energy sensitivity. In this paper we present the excellent polarimetric performance of the Gas Pixel Detector at energies where the peak sensitivity is expected. These measurements not only support our previous claims of high sensitivity but confirm the feasibility of astrophysical X-ray photoelectric polarimetry.

astro-ph

SuperAGILE: the hard X-ray Imager for the AGILE space mission

SuperAGILE is a coded mask experiment based on silicon microstrip detectors. It operates in the 15-45 keV nominal energy range, providing crossed one-dimensional images of the X-ray sky with an on-axis angular resolution of 6 arcmin, over a field of view in excess of 1 steradian. It was designed as the hard X-ray monitor of the AGILE space mission, a small satellite of the Italian Space Agency devoted to image the gamma-ray sky in the 30 MeV - 50 GeV energy band. The AGILE mission was launched in a low-earth orbit on 23^{rd} April 2007. In this paper we describe the SuperAGILE experiment, its construction and test processes, and its performance before flight, based on the on-ground test and calibrations.

astro-ph

Fragmentation studies of high energy ions using CR39 nuclear track detectors

We report on the measurements of the total charge changing fragmentation cross sections in high-energy nucleus-nucleus collisions using Fe, Si and Pb incident ions. Several stacks of CR39 nuclear track detectors with different target combinations were exposed at normal incidence to high energy accelerator beams to integrated densities of about 2000 ions/cm^2. The nuclear track detector foils were chemically etched, and ion tracks were measured using an automatic image analyzer system. The cross section determination is based on the charge identification of beam ions and their fragments and on the reconstruction of their path through the stacks.

physics.ins-det

Search for Intermediate Mass Magnetic Monopoles and Nuclearites with the SLIM experiment

SLIM is a large area experiment (440 m2) installed at the Chacaltaya cosmic ray laboratory since 2001, and about 100 m2 at Koksil, Himalaya, since 2003. It is devoted to the search for intermediate mass magnetic monopoles (107-1013 GeV/c2) and nuclearites in the cosmic radiation using stacks of CR39 and Makrofol nuclear track detectors. In four years of operation it will reach a sensitivity to a flux of about 10-15 cm-2 s-1 sr-1. We present the results of the calibration of CR39 and Makrofol and the analysis of a first sample of the exposed detector.

hep-ex