Searcharxiv⌕ Search

arXiv subjects

M. Gómez Berisso

Publications and source records attributed to M. Gómez Berisso.

At least 19 recordsLinked to original sources

Measuring the CMB primordial B-modes with Bolometric Interferometry

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is the first bolometric interferometer designed to measure the primordial B-mode polarization of the Cosmic Microwave Background (CMB). Bolometric interferometry is a novel technique that combines the sensitivity of bolometric detectors with the control of systematic effects that is typical of interferometry, both key features in the quest for the faint signal of the primordial B-modes. A unique feature is the so-called "spectral imaging", i.e., the ability to recover the sky signal in several sub-bands within the physical band during data analysis. This feature provides an in-band spectral resolution of Δν/ν \sim 0.04 that is unattainable by a traditional imager. This is a key tool for controlling the Galactic foregrounds contamination. In this paper, we describe the principles of bolometric interferometry, the current status of the QUBIC experiment and future prospects.

astro-ph.CO↗

Status of QUBIC, the Q&U Bolometer for Cosmology

The Q&U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Back-ground (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematics with those of bolometric detectors in terms of wide-band, background-limited sensitivity.

astro-ph.IM↗

QUBIC VII: The feedhorn-switch system of the technological demonstrator

We present the design, manufacturing and performance of the horn-switch system developed for the technological demonstrator of QUBIC (the $Q$\&$U$ Bolometric Interferometer for Cosmology). This system is constituted of 64 back-to-back dual-band (150\,GHz and 220\,GHz) corrugated feed-horns interspersed with mechanical switches used to select desired baselines during the instrument self-calibration. We manufactured the horns in aluminum platelets milled by photo-chemical etching and mechanically tightened with screws. The switches are based on steel blades that open and close the wave-guide between the back-to-back horns and are operated by miniaturized electromagnets. We also show the current development status of the feedhorn-switch system for the QUBIC full instrument, based on an array of 400 horn-switch assemblies.

astro-ph.IM↗

QUBIC II: Spectro-Polarimetry with Bolometric Interferometry

Bolometric interferometry is a novel technique that has the ability to perform spectral imaging. A bolometric interferometer observes the sky in a wide frequency band and can reconstruct sky maps in several sub-bands within the physical band in post-processing of the data. This provides a powerful spectral method to discriminate between the cosmic microwave background (CMB) and astrophysical foregrounds. In this paper, the methodology is illustrated with examples based on the Q \& U Bolometric Interferometer for Cosmology (QUBIC) which is a ground-based instrument designed to measure the B-mode polarization of the sky at millimeter wavelengths. We consider the specific cases of point source reconstruction and Galactic dust mapping and we characterize the point spread function as a function of frequency. We study the noise properties of spectral imaging, especially the correlations between sub-bands, using end-to-end simulations together with a fast noise simulator. We conclude showing that spectral imaging performance are nearly optimal up to five sub-bands in the case of QUBIC.

astro-ph.IM↗

QUBIC III: Laboratory Characterization

A prototype version of the Q & U Bolometric Interferometer for Cosmology (QUBIC) underwent a campaign of testing in the laboratory at Astroparticle Physics and Cosmology in Paris. We report the results of this Technological Demonstrator which successfully shows the feasibility of the principle of Bolometric Interferometry. Characterization of QUBIC includes the measurement of the synthesized beam, the measurement of interference fringes, and the measurement of polarization performance. A modulated and frequency tunable millimetre-wave source in the telescope far-field is used to simulate a point source. The QUBIC pointing is scanned across the point source to produce beam maps. Polarization modulation is measured using a rotating Half Wave Plate. The measured beam matches well to the theoretical simulations and gives QUBIC the ability to do spectro imaging. The polarization performance is excellent with less than 0.5\% cross-polarization rejection. QUBIC is ready for deployment on the high altitude site at Alto Chorillo, Argentina to begin scientific operations.

astro-ph.IM↗

Neutron Imaging Based on Transfer Foil Activation and COTS CMOS Image Sensors

In this paper we present a method for obtention of neutron images with Commercial-Off-The-Shelf (COTS) CMOS image sensors through the activation of indium foils. This detection method has been designed specifically for the acquisition of thermal and epitermal neutron images in mixed beams with a high gamma flux, and also for the study of high radioactive samples that are usually placed into research reactor pools. We also present a technique to obtain multi-spectral neutron images taking advantage of the high neutron absorption cross-section of this material in the thermal energy range, as well as around the 1.45 eV resonance. Measurements performed in a neutron beam of the RA6 nuclear research reactor located in Bariloche, Argentina, confirm the capability of the proposed technique.

physics.ins-det↗

PlomBOX -- development of a low-cost CMOS device for environmental monitoring

This paper reports on the development of a novel CMOS device employing lead-sensing bacteria to assay lead in drinking water. The objective of the PlomBOX project is to develop a low-cost sensor (£10) which can expedite access to on-demand assay methods and thus help mitigate lead intake through contaminated drinking water. The project follows three development paths: a) Certain bacteria can fluoresce or change colour when in the presence of lead. A genetically modified strain of Escherichia coli sensitive to lead concentrations up to 10 ppb is being developed. This constitutes the biosensor that fluoresces in proportion to the presence of lead. b) Bacteria response is imaged using a microprocessor (ESP32) with a camera module. This constitutes the optical metrology component of the PlomBOX. c) Data acquisition and control of the PlomBOX is achieved through a Bluetooth connection with the PlomApp, a custom-developed mobile phone application. Data are sent from the PlomApp to a database where a bespoke automated analysis software provides a result of the lead concentration in a sample of water. This paper reports on the instrumentation challenges of developing the electronics for the PlomBOX and on the first prototype.

physics.ins-det↗

QUBIC I: Overview and ScienceProgram

The Q $\&$ U Bolometric Interferometer for Cosmology (QUBIC) is a novel kind of polarimeter optimized for the measurement of the B-mode polarization of the Cosmic Microwave Background (CMB), which is one of the major challenges of observational cosmology. The signal is expected to be of the order of a few tens of nK, prone to instrumental systematic effects and polluted by various astrophysical foregrounds which can only be controlled through multichroic observations. QUBIC is designed to address these observational issues with a novel approach that combines the advantages of interferometry in terms of control of instrumental systematic effects with those of bolometric detectors in terms of wide-band, background-limited sensitivity. The QUBIC synthesized beam has a frequency-dependent shape that results in the ability to produce maps of the CMB polarization in multiple sub-bands within the two physical bands of the instrument (150 and 220 GHz). These features make QUBIC complementary to other instruments and makes it particularly well suited to characterize and remove Galactic foreground contamination. In this article, first of a series of eight, we give an overview of the QUBIC instrument design, the main results of the calibration campaign, and present the scientific program of QUBIC including not only the measurement of primordial B-modes, but also the measurement of Galactic foregrounds. We give forecasts for typical observations and measurements: with three years of integration on the sky and assuming perfect foreground removal as well as stable atmospheric conditions from our site in Argentina, our simulations show that we can achieve a statistical sensitivity to the effective tensor-to-scalar ratio (including primordial and foreground B-modes) $σ(r)=0.015$.

astro-ph.IM↗

QUBIC V: Cryogenic system design and performance

Current experiments aimed at measuring the polarization of the Cosmic Microwave Background (CMB) use cryogenic detector arrays and cold optical systems to boost the mapping speed of the sky survey. For these reasons, large volume cryogenic systems, with large optical windows, working continuously for years, are needed. Here we report on the cryogenic system of the QUBIC (Q and U Bolometric Interferometer for Cosmology) experiment: we describe its design, fabrication, experimental optimization and validation in the Technological Demonstrator configuration. The QUBIC cryogenic system is based on a large volume cryostat, using two pulse-tube refrigerators to cool at ~3K a large (~1 m^3) volume, heavy (~165kg) instrument, including the cryogenic polarization modulator, the corrugated feedhorns array, and the lower temperature stages; a 4He evaporator cooling at ~1K the interferometer beam combiner; a 3He evaporator cooling at ~0.3K the focal-plane detector arrays. The cryogenic system has been tested and validated for more than 6 months of continuous operation. The detector arrays have reached a stable operating temperature of 0.33K, while the polarization modulator has been operated from a ~10K base temperature. The system has been tilted to cover the boresight elevation range 20 deg -90 deg without significant temperature variations. The instrument is now ready for deployment to the high Argentinean Andes.

astro-ph.IM↗

QUBIC VI: cryogenic half wave plate rotator, design and performances

Inflation Gravity Waves B-Modes polarization detection is the ultimate goal of modern large angular scale cosmic microwave background (CMB) experiments around the world. A big effort is undergoing with the deployment of many ground-based, balloon-borne and satellite experiments using different methods to separate this faint polarized component from the incoming radiation. One of the largely used technique is the Stokes Polarimetry that uses a rotating half-wave plate (HWP) and a linear polarizer to separate and modulate the polarization components with low residual cross-polarization. This paper describes the QUBIC Stokes Polarimeter highlighting its design features and its performances. A common systematic with these devices is the generation of large spurious signals synchronous with the rotation and proportional to the emissivity of the optical elements. A key feature of the QUBIC Stokes Polarimeter is to operate at cryogenic temperature in order to minimize this unwanted component. Moving efficiently this large optical element at low temperature constitutes a big engineering challenge in order to reduce friction power dissipation. Big attention has been given during the designing phase to minimize the differential thermal contractions between parts. The rotation is driven by a stepper motor placed outside the cryostat to avoid thermal load dissipation at cryogenic temperature. The tests and the results presented in this work show that the QUBIC polarimeter can easily achieve a precision below 0.1° in positioning simply using the stepper motor precision and the optical absolute encoder. The rotation induces only few mK of extra power load on the second cryogenic stage (~ 8 K).

astro-ph.IM↗

QUBIC: using NbSi TESs with a bolometric interferometer to characterize the polarisation of the CMB

QUBIC (Q \& U Bolometric Interferometer for Cosmology) is an international ground-based experiment dedicated in the measurement of the polarized fluctuations of the Cosmic Microwave Background (CMB). It is based on bolometric interferometry, an original detection technique which combine the immunity to systematic effects of an interferometer with the sensitivity of low temperature incoherent detectors. QUBIC will be deployed in Argentina, at the Alto Chorrillos mountain site near San Antonio de los Cobres, in the Salta province. The QUBIC detection chain consists in 2048 NbSi Transition Edge Sensors (TESs) cooled to 350mK.The voltage-biased TESs are read out with Time Domain Multiplexing based on Superconducting QUantum Interference Devices (SQUIDs) at 1 K and a novel SiGe Application-Specific Integrated Circuit (ASIC) at 60 K allowing to reach an unprecedented multiplexing (MUX) factor equal to 128. The QUBIC experiment is currently being characterized in the lab with a reduced number of detectors before upgrading to the full instrument. I will present the last results of this characterization phase with a focus on the detectors and readout system.

astro-ph.IM↗

Contributions of the LAGO Collaboration to the 36th ICRC

The LAGO (Latin American Giant Observatory) observatory is an experiment that spans over Latin America in a wide range of latitudes that gives different rigidity cut offs for the enter of cosmic rays in the atmosphere. The motivation of the Observatory is to study atmospheric radiation and space weather through the measurement of the secondary emission of low energy cosmic rays at ground level using Water Cherenkov Detectors (WCD). This work presents the contributions of the LAGO collaboration to the 2019 36th ICRC.

hep-ex↗

The Latin American Giant Observatory: Contributions to the 34th International Cosmic Ray Conference (ICRC 2015)

The Latin American Giant Observatory (LAGO) is an extended cosmic ray observatory composed by a network of water-Cherenkov detectors spanning over different sites located at significantly different altitudes (from sea level up to more than $5000$\,m a.s.l.) and latitudes across Latin America, covering a huge range of geomagnetic rigidity cut-offs and atmospheric absorption/reaction levels. This detection network is designed to measure the temporal evolution of the radiation flux at ground level with extreme detail. The LAGO project is mainly oriented to perform basic research in three branches: high energy phenomena, space weather and atmospheric radiation at ground level. LAGO is built and operated by the LAGO Collaboration, a non-centralized collaborative union of more than 30 institutions from ten countries. These are the contributions of the LAGO Collaboration to the 34th International Cosmic Ray Conference, 30 July - 6 August 2015, The Hague, The Netherlands

astro-ph.IM↗

Exploring high temperature magnetic order in CeTi_1-xSc_xGe

Most of magnetic transitions related to Ce ordering are found below T_ord~12K. Among the few cases exceeding that temperature, two types of behaviors can be distinguished. One of them is related to the rare cases of Ce binary compounds formed in BCC structures, with a quartet ground state, whose degeneracy is reduced by undergoing different types of transitions mostly structural. The other group shows evidences of itinerant character with the outstanding example of CeRh_3B_2 showing the highest T_ord=115K. The second highest ordering temperature has been reported for CeScGe with T_ord=47K, but the nature of this magnetic state has not been investigated very deeply. In order to shed more light into this unusual high temperature ordering we studied the structural, magnetic, transport and thermal properties of CeTi_1-xSc_xGe alloys in the stability range of the CeScSi-type structure 0.25 0.65, the magnetic phase boundary splits into two transitions, with an intermediate phase presenting incommensurate spin density waves features.

cond-mat.str-el↗

From magnetic to Fermi Liquid behavior in CeCo{1-x}Fe{x}Si alloys

Structural, magnetic and thermal measurements performed on CeCo{1-x}Fe{x}Si alloys are reported. Three regions can be recognized: i) Co-rich (x < 0.20) with a decreasing long range antiferromagnetic order which vanishes at finite temperature, ii) an intermediate region (0.20 < x < 0.30) showing a broad magnetic anomaly (C_A) in specific heat and iii) the non-magnetic region progressively changing from a non-Fermi-liquid type behavior towards a Fermi liquid one as Fe concentration increases. The C_A anomaly emerges as an incipient contribution above T_N already at x = 0.10, which indicates that this contribution is related to short range correlations likely of quasi-two dimensional type. Both, T_N transition and C_A anomaly are practically not affected by applied magnetic field up to B ~ 10 Tesla.

cond-mat.str-el↗

Tri-critical point and suppression of the Shastry-Sutherland phase in Ce$_{2}$Pd$_{2}$Sn by Ni doping

Structural, magnetization and heat capacity measurements were performed on Ce$_2$(Pd$_{1-x}$Ni$_x$)$_2$Sn ($0 \leq x \leq 0.25$) alloys, covering the full range of the Mo$_2$FeB$_2$ structure stability. In this system, the two transitions observed in Ce$_2$Pd$_2$Sn (at $T_N=4.8$\,K and $T_C=2.1$\,K respectively) converge into a tri-critical point at $T_{cr}\approx 3.4$\,K for $x\approx 0.3$, where the intermediate antiferromagnetic AF phase is suppressed. The $T_N(x)$ phase boundary decrease is due to an incipient Kondo screening of the Ce-4f moments and local atomic disorder in the alloy. Both mechanisms affect the formation of Ce-magnetic dimers on which the Shastry-Sutherland lattice (SSL) builds up. On the contrary, the $T_C(x)$ transition to the ferromagnetic ground state increases as a consequence of the weakening of the AF-SSL phase. Applied magnetic field also suppresses the AF phase like in the stoichiometric compound.

cond-mat.str-el↗

Electron concentration effects on the Shastry-Sutherland phase stability in Ce_{2-x}Pd_{2+y}In_{1-z} solid solutions

The stability of a Shastry-Sutherland ShSu phase as a function of electron concentration is investigated through the field dependence of thermal and magnetic properties of the solid solution Ce_{2-x}Pd_{2+y}In_{1-z} in the antiferromagnetic branch. In these alloys the electronic (holes) variation is realized by increasing $Pd$ concentration. The AF transition T_M decreases from 3.5K to 2.8K as $Pd$ concentration increases from y=0.2 to y=0.4. By applying magnetic field, the ShSu phase is suppressed once the field induced ferromagnetic polarization takes over at a critical field B_{cr} which increases with $Pd$ content. A detailed analysis around the critical point reveals a structure in the maximum of the dM/dB derivative, which is related with incipient steps in the magnetization M(B) as predicted by the theory for the ShSu lattice. The crossing of M(B) isotherms, observed in ShSu prototype compounds, is also analyzed. The effect of $In$ substitution by $Pd$ is interpreted as an increase of the number of 'holes' in the conduction band and results in a unique parameter able to describe the variation of the magnetic properties along the studied range of concentration.

cond-mat.str-el↗

Underground Muon Counters as a Tool for Composition Analyses

The transition energy from galactic to extragalactic cosmic ray sources is still uncertain, but it should be associated either with the region of the spectrum known as the second knee or with the ankle. The baseline design of the Pierre Auger Observatory was optimized for the highest energies. The surface array is fully efficient above $3 \times 10^{18}$ eV and, even if the hybrid mode can extend this range below $10^{18}$ eV, the second knee and a considerable portion of the wide ankle structure are left outside its operating range. Therefore, in order to encompass these spectral features and gain further insight into the cosmic ray composition variation along the transition region, enhancements to the surface and fluorescence components of the baseline design are being implemented that will lower the full efficiency regime of the Observatory down to $\sim 10^{17}$ eV. The surface enhancements consist of a graded infilled area of standard Auger water Cherenkov detectors deployed in two triangular grids of 433 m and 750 m of spacing. Each surface station inside this area will have an associated muon counter detector. The fluorescence enhancement, on the other hand, consists of three additional fluorescence telescopes with higher elevation angle ($30^\circ-58^\circ$) than the ones in operation at present. The aim of this paper is threefold. We study the effect of the segmentation of the muon counters and find an analytical expression to correct for the under counting due to muon pile-up. We also present a detailed method to reconstruct the muon lateral distribution function for the 750 m spacing array. Finally, we study the mass discrimination potential of a new parameter, the number of muons at 600 m from the shower axis, obtained by fitting the muon data with the above mentioned reconstruction method.

astro-ph↗