SearcharxivSearch

arXiv subjects

M. Gericke

Publications and source records attributed to M. Gericke.

17 recordsLinked to original sources

Precision Neutron Skins of $^{208}$Pb and $^{48}$Ca from Parity-Violating Electron Scattering

We have measured the parity-violating elastic electron scattering asymmetry in the PREX and CREX experiments on ${}^{208}$Pb and ${}^{48}$Ca respectively; these are both doubly-magic nuclei whose excited states can be discriminated from the ground state by the high resolution spectrometers in Hall A at Jefferson Lab. This asymmetry provides a precise determination of the weak charge form factor at one $Q^2$ and pins down the neutron radius in these two nuclei in a relatively clean and model-independent way. This is because the $Z^0$ boson of the weak interaction couples primarily to neutrons. The heavier lead nucleus, with a neutron excess, provides an interpretation of the neutron skin thickness in terms of properties of bulk neutron matter. For the lighter ${}^{48}$Ca nucleus, which is also rich in neutrons, comparisons to microscopic nuclear theory calculations are sensitive to poorly constrained 3-neutron forces. The weak neutral form factors $F_W(Q^2)$ were extracted to be $0.368 \pm 0.013$ at $Q = 0.3977 {\rm\ fm}^{-1}$ for $^{208}$Pb from PREX-2 and $0.1304 \pm 0.0055$ at $Q = 0.8733 {\rm\ fm}^{-1}$ for $^{48}$Ca. The form factor differences $(F_{ch}-F_W)(Q^2)$ were calculated to be $0.041 \pm 0.013$ at $Q = 0.3977 {\rm fm}^{-1}$ for $^{208}$Pb from PREX-2 and $0.0277 \pm 0.0055$ at $Q = 0.8733 {\rm fm}^{-1}$ for $^{48}$Ca. Correcting for Coulomb distortions and using nuclear model information, we find the neutron skin thicknesses to be $R^{208}_{\rm skin} = 0.283 \pm 0.071$ fm combining PREX-1 and PREX-2 and $R^{48}_{\rm skin} = 0.121 \pm 0.035$ fm. This paper provides a full description of the special experimental and data analysis techniques employed for precisely measuring these small asymmetries.

nucl-ex

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Ultra-High precision Compton polarimetry at 2 GeV

We report a high precision measurement of electron beam polarization using Compton polarimetry. The measurement was made in experimental Hall A at Jefferson Lab during the CREX experiment in 2020. A total uncertainty of dP/P=0.36% was achieved detecting the back-scattered photons from the Compton scattering process. This is the highest accuracy in a measurement of electron beam polarization using Compton scattering ever reported, surpassing the ground-breaking measurement from the SLAC Large Detector (SLD) Compton polarimeter. Such uncertainty reaches the level required for the future flagship measurements to be made by the MOLLER and SoLID experiments.

physics.ins-det

Searching for New Physics with DarkLight at the ARIEL Electron-Linac

The search for a dark photon holds considerable interest in the physics community. Such a force carrier would begin to illuminate the dark sector. Many experiments have searched for such a particle, but so far it has proven elusive. In recent years the concept of a low mass dark photon has gained popularity in the physics community. Of particular recent interest is the $^8$Be and $^4$He anomaly, which could be explained by a new fifth force carrier with a mass of 17 MeV/$c^2$. The proposed DarkLight experiment would search for this potential low mass force carrier at ARIEL in the 10-20 MeV e$^+$e$^-$ invariant mass range. This proceeding will focus on the experimental design and physics case of the DarkLight experiment.

nucl-ex

Snowmass 2021 White Paper on Upgrading SuperKEKB with a Polarized Electron Beam: Discovery Potential and Proposed Implementation

Upgrading the SuperKEKB electron-positron collider with polarized electron beams opens a new program of precision physics at a center-of-mass energy of 10.58 GeV. This white paper describes the physics potential of this `Chiral Belle' program. It includes projections for precision measurements of $\sin^2\theta_W$ that can be obtained from independent left-right asymmetry measurements of $e^+e^-$ transitions to pairs of electrons, muons, taus, charm and b-quarks. The $\sin^2\theta_W$ precision obtainable at SuperKEKB will match that of the LEP/SLC world average, but at the centre-of-mass energy of 10.58 GeV. Measurements of the couplings for muons, charm, and $b$-quarks will be substantially improved and the existing $3\sigma$ discrepancy between the SLC $A_{LR}$ and LEP $A_{FB}^b$ measurements will be addressed. Precision measurements of neutral current universality will be more than an order of magnitude more precise than currently available. As the energy scale is well away from the $Z^0$-pole, the precision measurements will have sensitivity to the presence of a parity-violating dark sector gauge boson, $Z_{\rm dark}$. The program also enables the measurement of the anomalous magnetic moment $g-2$ form factor of the $\tau$ to be made at an unprecedented level of precision. A precision of $10^{-5}$ level is accessible with 40~ab$^{-1}$ and with more data it would start to approach the $10^{-6}$ level. This technique would provide the most precise information from the third generation about potential new physics explanations of the muon $g-2$ $4\sigma$ anomaly. Additional $\tau$ and QCD physics programs enabled or enhanced with having polarized electron beams are also discussed in this White Paper. This paper includes a summary of the path forward in R&D and next steps required to implement this upgrade and access its exciting discovery potential.

physics.acc-ph

Precision Determination of the Neutral Weak Form Factor of $^{48}$Ca

We report a precise measurement of the parity-violating asymmetry $A_{\rm PV}$ in the elastic scattering of longitudinally polarized electrons from $^{48}{\rm Ca}$. We measure $A_{\rm PV} =2668\pm 106\ {\rm (stat)}\pm 40\ {\rm (syst)}$ parts per billion, leading to an extraction of the neutral weak form factor $F_{\rm W} (q=0.8733$ fm$^{-1}) = 0.1304 \pm 0.0052 \ {\rm (stat)}\pm 0.0020\ {\rm (syst)}$ and the charge minus the weak form factor $F_{\rm ch} - F_{\rm W} = 0.0277\pm 0.0055$. The resulting neutron skin thickness $R_n-R_p=0.121 \pm 0.026\ {\rm (exp)} \pm 0.024\ {\rm (model)}$~fm is relatively thin yet consistent with many model calculations. The combined CREX and PREX results will have implications for future energy density functional calculations and on the density dependence of the symmetry energy of nuclear matter.

nucl-ex

New Measurements of the Beam-Normal Single Spin Asymmetry in Elastic Electron Scattering Over a Range of Spin-0 Nuclei

We report precision determinations of the beam normal single spin asymmetries ($A_n$) in the elastic scattering of 0.95 and 2.18~GeV electrons off $^{12}$C, $^{40}$Ca, $^{48}$Ca, and $^{208}$Pb at very forward angles where the most detailed theoretical calculations have been performed. The first measurements of $A_n$ for $^{40}$Ca and $^{48}$Ca are found to be similar to that of $^{12}$C, consistent with expectations thus demonstrating the validity of theoretical calculations for nuclei with Z~$\leq20$. We also report $A_n$ for $^{208}$Pb at two new momentum transfers (Q$^2$) extending the previous measurement. Our new data confirm the surprising result previously reported, with all three data points showing significant disagreement with the results from the $Z\leq 20$ nuclei. These data confirm our basic understanding of the underlying dynamics that govern $A_n$ for nuclei containing $\lesssim 50$ nucleons, but point to the need for further investigation to understand the unusual $A_n$ behaviour discovered for scattering off $^{208}$Pb.

nucl-ex

Accurate Determination of the Neutron Skin Thickness of $^{208}$Pb through Parity-Violation in Electron Scattering

We report a precision measurement of the parity-violating asymmetry $A_{PV}$ in the elastic scattering of longitudinally polarized electrons from $^{208}$Pb. We measure $A_{PV}=550\pm 16 {\rm (stat)}\pm 8\ {\rm (syst)}$ parts per billion, leading to an extraction of the neutral weak form factor $F_W(Q^2 = 0.00616\ {\rm GeV}^2) = 0.368 \pm 0.013$. Combined with our previous measurement, the extracted neutron skin thickness is $R_n-R_p=0.283 \pm 0.071$~fm. The result also yields the first significant direct measurement of the interior weak density of $^{208}$Pb: $\rho^0_W = -0.0796\pm0.0036\ {\rm (exp.)}\pm0.0013\ {\rm (theo.)}\ {\rm fm}^{-3}$ leading to the interior baryon density $\rho^0_b = 0.1480\pm0.0036\ {\rm (exp.)}\pm0.0013\ {\rm (theo.)}\ {\rm fm}^{-3}$. The measurement accurately constrains the density dependence of the symmetry energy of nuclear matter near saturation density, with implications for the size and composition of neutron stars.

nucl-ex

First ultracold neutrons produced at TRIUMF

We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.

physics.ins-det

Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized $^{3}$He neutron spin-filter

Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per second per cm$^2$ and a cross sectional area of 10$\times$12~cm$^2$. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized $^{3}$He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the $^{3}$He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating $\gamma$-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.

physics.ins-det

Study of Light Backgrounds from Relativistic Electrons in Air Light-Guides

The MOLLER experiment proposed at the Thomas Jefferson National Accelerator Facility plans a precision low energy determination of the weak mixing angle via the measurement of the parity-violating asymmetry in the scattering of high energy longitudinally polarized electrons from electrons bound in a liquid hydrogen target (M{\o}ller scattering). A relative measure of the scattering rate is planned to be obtained by intercepting the M{\o}ller scattered electrons with a circular array of thin fused silica tiles attached to air light guides, which facilitate the transport of Cherenkov photons generated within the tiles to photomultiplier tubes (PMTs). The scattered flux will also pass through the light guides of downstream tiles, generating additional Cherenkov as well as scintillation light and is a potential background. In order to estimate the rate of these backgrounds, a gas-filled tube detector was designed and deployed in an electron beam at the MAMI facility at Johannes Gutenberg University, Mainz, Germany. Described in this paper is the design of a detector to measure separately the scintillation and Cherenkov responses of gas mixtures from relativistic electrons, the results of studies of several gas mixtures with comparisons to simulations, and conclusions about the implications for the design of the MOLLER detector apparatus.

physics.ins-det

New measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission

Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function $g(r)$ inferred from neutron scattering measurements of the differential cross section $dσ\over dΩ$ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43~meV and 16.1~meV on liquid hydrogen at 15.6~K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1~meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra non-equilibrium component of orthohydrogen. Liquid parahydrogen is also a widely-used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. We describe our measurements and compare them with previous work.

nucl-ex

The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge

We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.

physics.ins-det