Searcharxiv⌕ Search

arXiv subjects

M. Green

Publications and source records attributed to M. Green.

29 records · Page 2Linked to original sources

Characterization of large area APDs for the EXO-200 detector

EXO-200 uses 468 large area avalanche photodiodes (LAAPDs) for detection of scintillation light in an ultra-low-background liquid xenon (LXe) detector. We describe initial measurements of dark noise, gain and response to xenon scintillation light of LAAPDs at temperatures from room temperature to 169K - the temperature of liquid xenon. We also describe the individual characterization of more than 800 LAAPDs for selective installation in the EXO-200 detector.

physics.ins-det↗

Weakly coupled $s = 1/2$ quantum spin singlets in Ba$_{3}$Cr$_{2}$O$_{8}$

Using single crystal inelastic neutron scattering with and without application of an external magnetic field and powder neutron diffraction, we have characterized magnetic interactions in Ba$_3$Cr$_2$O$_8$. Even without field, we found that there exist three singlet-to-triplet excitation modes in $(h,h,l)$ scattering plane. Our complete analysis shows that the three modes are due to spatially anisotropic interdimer interactions that are induced by local distortions of the tetrahedron of oxygens surrounding the Jahn-Teller active Cr$^{5+} (3d^1)$. The strong intradimer coupling of $J_0 = 2.38(2)$ meV and weak interdimer interactions ($|J_{\rm inter}| \leq 0.52(2)$ meV) makes Ba$_3$Cr$_2$O$_8$ a good model system for weakly-coupled $s = 1/2$ quantum spin dimers.

cond-mat.str-el↗

Systematic study of trace radioactive impurities in candidate construction materials for EXO-200

The Enriched Xenon Observatory (EXO) will search for double beta decays of 136Xe. We report the results of a systematic study of trace concentrations of radioactive impurities in a wide range of raw materials and finished parts considered for use in the construction of EXO-200, the first stage of the EXO experimental program. Analysis techniques employed, and described here, include direct gamma counting, alpha counting, neutron activation analysis, and high-sensitivity mass spectrometry.

physics.ins-det↗

Structure and Magnetic Order in the NdFeAs(O,F) Superconductor System

The transition temperature Tc~26 K of the recently discovered superconductor LaFeAs(O,F) has been demonstrated to be extremely sensitive to the lanthanide ion, reaching 55 K for the Sm containing oxypnictides. Therefore, it is important to determine how the moment on the lanthanide affects the overall magnetism in these systems. Here we report a neutron diffraction study of the Nd oxypnictides. Long ranged antiferromagnetic order is apparent in NdFeAsO below 1.96 K. Rietveld refinement shows that both Fe and Nd magnetic ordering are required to describe the observed data with the staggered moment 1.55(4) Bohr magneton per Nd and 0.9(1) Bohr magneton per Fe at 0.3 K. The other structural properties such as the tetragonal-orthorhombic distortion are found to be very similar to those in LaFeAsO. Neither the magnetic ordering nor the structural distortion occur in the superconducting sample NdFeAsO0.80F0.20 at any temperatures down to 1.5 K.

cond-mat.supr-con↗

A microfabricated sensor for thin dielectric layers

We describe a sensor for the measurement of thin dielectric layers capable of operation in a variety of environments. The sensor is obtained by microfabricating a capacitor with interleaved aluminum fingers, exposed to the dielectric to be measured. In particular, the device can measure thin layers of solid frozen from a liquid or gaseous medium. Sensitivity to single atomic layers is achievable in many configurations and, by utilizing fast, high sensitivity capacitance read out in a feedback system onto environmental parameters, coatings of few layers can be dynamically maintained. We discuss the design, read out and calibration of several versions of the device optimized in different ways. We specifically dwell on the case in which atomically thin solid xenon layers are grown and stabilized, in cryogenic conditions, from a liquid xenon bath.

physics.gen-ph↗

Observation of single collisionally cooled trapped ions in a buffer gas

Individual Ba ions are trapped in a gas-filled linear ion trap and observed with a high signal-to-noise ratio by resonance fluorescence. Single-ion storage times of ~5 min (~1 min) are achieved using He (Ar) as a buffer gas at pressures in the range 8e-5 - 4e-3 torr. Trap dynamics in buffer gases are experimentally studied in the simple case of single ions. In particular, the cooling effects of light gases such as He and Ar and the destabilizing properties of heavier gases such as Xe are studied. A simple model is offered to explain the observed phenomenology.

physics.atom-ph↗

A linear RFQ ion trap for the Enriched Xenon Observatory

The design, construction, and performance of a linear radio-frequency ion trap (RFQ) intended for use in the Enriched Xenon Observatory (EXO) are described. EXO aims to detect the neutrinoless double-beta decay of $^{136}$Xe to $^{136}$Ba. To suppress possible backgrounds EXO will complement the measurement of decay energy and, to some extent, topology of candidate events in a Xe filled detector with the identification of the daughter nucleus ($^{136}$Ba). The ion trap described here is capable of accepting, cooling, and confining individual Ba ions extracted from the site of the candidate double-beta decay event. A single trapped ion can then be identified, with a large signal-to-noise ratio, via laser spectroscopy.

physics.ins-det↗

A liquid xenon ionization chamber in an all-fluoropolymer vessel

A novel technique has been developed to build vessels for liquid xenon ionization detectors entirely out of ultra-clean fluoropolymer. We describe the advantages in terms of low radioactivity contamination, provide some details of the construction techniques, and show the energy resolution achieved with a prototype all-fluoropolymer ionization detector.

physics.ins-det↗

Mobility of thorium ions in liquid xenon

We present a measurement of the $^{226}$Th ion mobility in LXe at 163.0 K and 0.9 bar. The result obtained, 0.240$\pm$0.011 (stat) $\pm$0.011 (syst) cm$^{2}$/(kV-s), is compared with a popular model of ion transport.

cond-mat.other↗

Status of Project GRAND's Proportional Wire Chamber Array

Project GRAND is an extensive air shower array of proportional wire chambers. It has 64 stations in a 100m x 100m area; each station has eight planes of proportional wire chambers with a 50 mm steel absorber plate above the bottom two planes. This arrangement of planes, each 1.25 square meters of area, allow an angular measurement for each track to 0.25 degrees in each of two projections. The steel absorber plate allows a measurement of the identity of each muon track to 96% accuracy. Two data-taking triggers allow data to be simultaneously taken for a) extensive air showers (multiple coincidence station hits) at about 1 Hz and b) single muons (single tracks of identified muons) at 2000 Hz. Eight on-line computers pre-analyze the single track data and store the results on magnetic tape in compacted form with a minimum of computer dead-time. One additional computer reads data from the shower triggers and records this raw data on a separate magnetic tape with no pre-analysis.

astro-ph↗

Muon Collider Design

Muon Colliders have unique technical and physics advantages and disadvantages when compared with both hadron and electron machines. They should thus be regarded as complementary. Parameters are given of 4 TeV and 0.5 TeV high luminosity μ^+ μ^- colliders, and of a 0.5 TeV lower luminosity demonstration machine. We discuss the various systems in such muon colliders, starting from the proton accelerator needed to generate the muons and proceeding through muon cooling, acceleration and storage in a collider ring. Detector background, polarization, and nonstandard operating conditions are discussed.

acc-phys↗