SearcharxivSearch

arXiv subjects

M. Guigue

Publications and source records attributed to M. Guigue.

At least 19 recordsLinked to original sources

Performance of the High-Angle Time Projection Chambers in the Upgraded T2K Off-Axis Near Detector

The off-axis magnetic near detector of the T2K experiment has undergone a significant upgrade, including the construction and installation of two new Time Projection Chambers featuring innovative resistive Micromegas technology and a field cage composed of thin composite walls. This paper provides a detailed description of the new components of the chambers, including the gas system, gas monitoring chambers, and data acquisition system. Additionally, it reports the results of extensive testing using both neutrino beams and cosmic rays, with comparisons between data and Monte Carlo simulations. The new detectors achieve improved spatial resolution and enhanced particle identification capabilities which are crucial for the precision goals of the T2K experiment.

physics.ins-det

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or ${}^{83\mathrm{m}}$Kr are detected via their $\approx$26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting $\lesssim$10 ms and changing in frequency by $\lesssim$1 MHz/ms. To detect these signals, the Project 8 collaboration developed a data acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

physics.ins-det

First measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions using an accelerator neutrino beam

We report the first measurement of neutron capture multiplicity in neutrino-oxygen neutral-current quasi-elastic-like interactions at the gadolinium-loaded Super-Kamiokande detector using the T2K neutrino beam, which has a peak energy of about 0.6 GeV. A total of 30 neutral-current quasi-elastic-like event candidates were selected from T2K data corresponding to an exposure of $1.76\times10^{20}$ protons on target. The $\gamma$ ray signals resulting from neutron captures were identified using a neural network. The flux-averaged mean neutron capture multiplicity was measured to be $1.37\pm0.33\text{ (stat.)}$$^{+0.17}_{-0.27}\text{ (syst.)}$, which is compatible within $2.3\,\sigma$ than predictions obtained using our nominal simulation. We discuss potential sources of systematic uncertainty in the prediction and demonstrate that a significant portion of this discrepancy arises from the modeling of hadron-nucleus interactions in the detector medium.

hep-ex

Characterization of the Electronic Noise in the Readout of Resistive Micromegas in the High-Angle Time Projection Chambers of the T2K Experiment

The two high-angle Time Projection Chambers of the T2K experiment are equipped with a new readout system based on resistive Micromegas detector technology, and utilize custom-made electronics based on AFTER chips for signal processing. This study analyzes and characterizes the electronic noise of the detector readout chain to develop a comprehensive noise model. The model enables the generation of Monte Carlo simulations to investigate systematic effects in signal processing. The analysis is based on data collected from 32 resistive Micromegas detectors, recorded without zero suppression. All detectors exhibit a quasi-identical and time-stable noise level. The developed analytical model accurately describes the observed noise, and derived Monte Carlo simulations show excellent agreement with experimental data.

physics.ins-det

Project 8 Apparatus for Cyclotron Radiation Emission Spectroscopy with $^\mathrm{83m}$Kr and Tritium

Cyclotron Radiation Emission Spectroscopy (CRES) is a novel technique for the precise measurement of relativistic electron energy. This technique is being employed by the Project~8 collaboration for measuring a high-precision tritium beta decay spectrum to perform a frequency-based measurement of the neutrino mass. In this work, we describe the Project 8 Phase II apparatus, used for the detection of the CRES signal from the conversion electrons of $\mathrm{^{83m}Kr}$ and the first CRES measurement of the beta-decay spectrum of molecular tritium.

physics.ins-det

Deep Learning Based Event Reconstruction for Cyclotron Radiation Emission Spectroscopy

The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization - may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment - a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium $\beta^-$-decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.

physics.ins-det

Measurements of the $\nu_{\mu}$ and $\bar{\nu}_{\mu}$-induced Coherent Charged Pion Production Cross Sections on $^{12}C$ by the T2K experiment

We report an updated measurement of the $\nu_{\mu}$-induced, and the first measurement of the $\bar{\nu}_{\mu}$-induced coherent charged pion production cross section on $^{12}C$ nuclei in the T2K experiment. This is measured in a restricted region of the final-state phase space for which $p_{\mu,\pi} > 0.2$ GeV, $\cos(\theta_{\mu}) > 0.8$ and $\cos(\theta_{\pi}) > 0.6$, and at a mean (anti)neutrino energy of 0.85 GeV using the T2K near detector. The measured $\nu_{\mu}$ CC coherent pion production flux-averaged cross section on $^{12}C$ is $(2.98 \pm 0.37 (stat.) \pm 0.31 (syst.) \substack{ +0.49 \\ -0.00 } \mathrm{ (Q^2\,model)}) \times 10^{-40}~\mathrm{cm}^{2}$. The new measurement of the $\bar{\nu}_{\mu}$-induced cross section on $^{12}{C}$ is $(3.05 \pm 0.71 (stat.) \pm 0.39 (syst.) \substack{ +0.74 \\ -0.00 } \mathrm{(Q^2\,model)}) \times 10^{-40}~\mathrm{cm}^{2}$. The results are compatible with both the NEUT 5.4.0 Berger-Sehgal (2009) and GENIE 2.8.0 Rein-Sehgal (2007) model predictions.

hep-ex

Updated T2K measurements of muon neutrino and antineutrino disappearance using 3.6 $\times$ 10$^{21}$ protons on target

Muon neutrino and antineutrino disappearance probabilities are identical in the standard three-flavor neutrino oscillation framework, but CPT violation and non-standard interactions can violate this symmetry. In this work we report the measurements of $\sin^{2} \theta_{23}$ and $\Delta m_{32}^2$ independently for neutrinos and antineutrinos. The aforementioned symmetry violation would manifest as an inconsistency in the neutrino and antineutrino oscillation parameters. The analysis discussed here uses a total of 1.97$\times$10$^{21}$ and 1.63$\times$10$^{21}$ protons on target taken with a neutrino and antineutrino beam respectively, and benefits from improved flux and cross-section models, new near detector samples and more than double the data reducing the overall uncertainty of the result. No significant deviation is observed, consistent with the standard neutrino oscillation picture.

hep-ex

First measurement of muon neutrino charged-current interactions on hydrocarbon without pions in the final state using multiple detectors with correlated energy spectra at T2K

This paper reports the first measurement of muon neutrino charged-current interactions without pions in the final state using multiple detectors with correlated energy spectra at T2K. The data was collected on hydrocarbon targets using the off-axis T2K near detector (ND280) and the on-axis T2K near detector (INGRID) with neutrino energy spectra peaked at 0.6 GeV and 1.1 GeV respectively. The correlated neutrino flux presents an opportunity to reduce the impact of the flux uncertainty and to study the energy dependence of neutrino interactions. The extracted double-differential cross sections are compared to several Monte Carlo neutrino-nucleus interaction event generators showing the agreement between both detectors individually and with the correlated result.

hep-ex

Cyclotron Radiation Emission Spectroscopy of Electrons from Tritium Beta Decay and $^{83\rm m}$Kr Internal Conversion

Project 8 has developed a novel technique, Cyclotron Radiation Emission Spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. We provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as $18553^{+18}_{-19}$ ($18548^{+19}_{-19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of $1.66\pm0.19$ eV in a resolution-optimized magnetic trap configuration by measuring $^{83\rm m}$Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity.

nucl-ex

A search for neutron-to-hidden-neutron oscillations in a ultra-cold neutron beam

Models that postulate the existence of hidden sectors address contemporary questions, such as the source of baryogenesis and the nature of dark matter. Among the possible mixing processes, neutron-to-hidden-neutron oscillations have been repeatedly tested with ultra-cold neutron storage and passing-through-wall experiments in the range of small ($\delta m<2$ peV) and large mass splitting ($\delta m>10$ neV), respectively. In this work, we present a new constraint in the oscillation parameter space derived from neutron disappearance in ultra-cold neutron beam experiments. The overall limit, which covers the intermediate mass-splitting range, is given by $\tau_{nn'}> 1$ s for $|\delta m| \in [2,69]$ peV (95\% C.L.).

hep-ph

Characterization of Charge Spreading and Gain of Encapsulated Resistive Micromegas Detectors for the Upgrade of the T2K Near Detector Time Projection Chambers

An upgrade of the near detector of the T2K long baseline neutrino oscillation experiment is currently being conducted. This upgrade will include two new Time Projection Chambers, each equipped with 16 charge readout resistive Micromegas modules. A procedure to validate the performance of the detectors at different stages of production has been developed and implemented to ensure a proper and reliable operation of the detectors once installed. A dedicated X-ray test bench is used to characterize the detectors by scanning each pad individually and to precisely measure the uniformity of the gain and the deposited energy resolution over the pad plane. An energy resolution of about 10% is obtained. A detailed physical model has been developed to describe the charge dispersion phenomena in the resistive Micromegas anode. The detailed physical description includes initial ionization, electron drift, diffusion effects and the readout electronics effects. The model provides an excellent characterization of the charge spreading of the experimental measurements and allowed the simultaneous extraction of gain and RC information of the modules.

physics.ins-det

Measurements of neutrino oscillation parameters from the T2K experiment using $3.6\times10^{21}$ protons on target

The T2K experiment presents new measurements of neutrino oscillation parameters using $19.7(16.3)\times10^{20}$ protons on target (POT) in (anti-)neutrino mode at the far detector (FD). Compared to the previous analysis, an additional $4.7\times10^{20}$ POT neutrino data was collected at the FD. Significant improvements were made to the analysis methodology, with the near-detector analysis introducing new selections and using more than double the data. Additionally, this is the first T2K oscillation analysis to use NA61/SHINE data on a replica of the T2K target to tune the neutrino flux model, and the neutrino interaction model was improved to include new nuclear effects and calculations. Frequentist and Bayesian analyses are presented, including results on $\sin^2\theta_{13}$ and the impact of priors on the $\delta_\mathrm{CP}$ measurement. Both analyses prefer the normal mass ordering and upper octant of $\sin^2\theta_{23}$ with a nearly maximally CP-violating phase. Assuming the normal ordering and using the constraint on $\sin^2\theta_{13}$ from reactors, $\sin^2\theta_{23}=0.561^{+0.021}_{-0.032}$ using Feldman--Cousins corrected intervals, and $\Delta{}m^2_{32}=2.494_{-0.058}^{+0.041}\times10^{-3}~\mathrm{eV^2}$ using constant $\Delta\chi^{2}$ intervals. The CP-violating phase is constrained to $\delta_\mathrm{CP}=-1.97_{-0.70}^{+0.97}$ using Feldman--Cousins corrected intervals, and $\delta_\mathrm{CP}=0,\pi$ is excluded at more than 90% confidence level. A Jarlskog invariant of zero is excluded at more than $2\sigma$ credible level using a flat prior in $\delta_\mathrm{CP}$, and just below $2\sigma$ using a flat prior in $\sin\delta_\mathrm{CP}$. When the external constraint on $\sin^2\theta_{13}$ is removed, $\sin^2\theta_{13}=28.0^{+2.8}_{-6.5}\times10^{-3}$, in agreement with measurements from reactor experiments. These results are consistent with previous T2K analyses.

hep-ex

Analysis of test beam data taken with a prototype of TPC with resistive Micromegas for the T2K Near Detector upgrade

In this paper we describe the performance of a prototype of the High Angle Time Projection Chambers (HA-TPCs) that are being produced for the Near Detector (ND280) upgrade of the T2K experiment. The two HA-TPCs of ND280 will be instrumented with eight Encapsulated Resistive Anode Micromegas (ERAM) on each endplate, thus constituting in total 32 ERAMs. This innovative technique allows the detection of the charge emitted by ionization electrons over several pads, improving the determination of the track position. The TPC prototype has been equipped with the first ERAM module produced for T2K and with the HA-TPC readout electronics chain and it has been exposed to the DESY Test Beam in order to measure spatial and dE/dx resolution. In this paper we characterize the performances of the ERAM and, for the first time, we compare them with a newly developed simulation of the detector response. Spatial resolution better than 800 ${\mu \rm m}$ and dE/dx resolution better than 10% are observed for all the incident angles and for all the drift distances of interest. All the main features of the data are correctly reproduced by the simulation and these performances fully fulfill the requirements for the HA-TPCs of T2K.

physics.ins-det

Tritium Beta Spectrum and Neutrino Mass Limit from Cyclotron Radiation Emission Spectroscopy

The absolute scale of the neutrino mass plays a critical role in physics at every scale, from the particle to the cosmological. Measurements of the tritium endpoint spectrum have provided the most precise direct limit on the neutrino mass scale. In this Letter, we present advances by Project 8 to the Cyclotron Radiation Emission Spectroscopy (CRES) technique culminating in the first frequency-based neutrino mass limit. With only a cm$^3$-scale physical detection volume, a limit of $m_\beta{<}$155 eV ($152$ eV) is extracted from the background-free measurement of the continuous tritium beta spectrum in a Bayesian (frequentist) analysis. Using $^{83{\rm m}}$Kr calibration data, an improved resolution of 1.66${\pm}$0.19 eV (FWHM) is measured, the detector response model is validated, and the efficiency is characterized over the multi-keV tritium analysis window. These measurements establish the potential of CRES for a high-sensitivity next-generation direct neutrino mass experiment featuring low background and high resolution.

nucl-ex

Determination of diffusion coefficients of mercury atoms in various gases from longitudinal spin relaxation in magnetic gradients

We present a method to measure the binary diffusion coefficient of mercury atoms in a gas at room temperature and low pressure. It is based on the measurement of the longitudinal spin relaxation of optically pumped mercury-199 atoms in a magnetic field gradient. We provide a consistent set of diffusion coefficients for helium-3, helium-4, argon, krypton, xenon, nitrogen, carbon dioxide, oxygen, and air.

physics.atom-ph

First observation of cyclotron radiation from MeV-scale ${\rm e}^{pm}$ following nuclear beta decay

We present an apparatus for detection of cyclotron radiation that allows a frequency-based beta energy determination in the 5 keV to 5 MeV range, characteristic of nuclear beta decays. The cyclotron frequency of the radiating beta particles in a magnetic field is used to determine the beta energy precisely. Our work establishes the foundation to apply the cyclotron radiation emission spectroscopy (CRES) technique, developed by the Project 8 collaboration, far beyond the 18-keV tritium endpoint region. We report initial measurements of beta^-s from 6He and beta^+s from 19Ne decays to demonstrate the broadband response of our detection system and assess potential systematic uncertainties for beta spectroscopy over the full (MeV) energy range. This work is an important benchmark for the practical application of the CRES technique to a variety of nuclei, in particular, opening its reach to searches for evidence of new physics beyond the TeV scale via precision beta-decay measurements.

nucl-ex

Scintillator ageing of the T2K near detectors from 2010 to 2021

The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9--2.2\% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator.

physics.ins-det