Searcharxiv⌕ Search

arXiv subjects

M. Harada

Publications and source records attributed to M. Harada.

At least 55 records · Page 3Linked to original sources

Proposal: JSNS$^2$-II

This article describes the goal and expected sensitivity of the JSNS$^2$-II experiment at J-PARC Materials and Life Science Experimental Facility (MLF). The JSNS$^2$-II experiment is the second phase of the JSNS$^2$ experiment (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) with two detectors which are located in 24 m (an existing detector) and 48 m (new one) baselines to improve the sensitivity of the search for sterile neutrinos, especially in the low $Δm^2$ region, which has been indicated by the global fit of the appearance mode. The new second detector has a similar structure as the existing JSNS$^2$ detector, which is already working. To compensate for the reduction of the neutrino flux due to the distance from the mercury target, the target mass of the Gd-loaded liquid scintillator which is the Linear AlkylBenzene (LAB) based liquid scintillator inside the acrylic vessel is 35 tons. To keep the same photo-coverage of the detector as the first detector, we will surround the acrylic vessel with 240 PMTs. With this experimental setup and 5 years (times 1 MW beam power) exposure, the sensitivity of the JSNS$^2$-II is significantly improved compared to the current JSNS$^2$, especially in the low $Δm^2$ oscillation parameter region. The JSNS$^2$-II can also confirm or refute the most of the oscillation parameters' space preferred by the previous experiments with 3 sigma C.L.. Considering these situations and world wide status of the sterile neutrino searches, we are eager to start the data taking with the two detector configuration from 2023. The fund to build the second detector was already secured.

hep-ex↗

Improved method for measuring low concentration radium and its application to the Super-Kamiokande Gadolinium project

Chemical extraction using a molecular recognition resin named "Empore Radium Rad Disk" was developed to improve sensitivity for the low concentration of radium (Ra). Compared with the previous method, the extraction process speed was improved by a factor of three and the recovery rate for $^{226}$Ra was also improved from 81$\pm$4% to $>$99.9%. The sensitivity on the 10$^{-1}$ mBq level was achieved using a high purity germanium detector. This improved method was applied to determine $^{226}$Ra in Gd$_2$(SO$_4$)$_3{\cdot}$8H$_2$O which will be used in the Super-Kamiokande Gadolinium project. The improvement and measurement results are reported in this paper.

physics.ins-det↗

The JSNS$^{2}$ data acquisition system

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24 m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium(Gd)-loaded liquid scintillator (LS) with an additional 31 tons of unloaded LS in the intermediate $γ$-catcher and an optically separated outer veto volumes. A total of 120 10-inch photomultiplier tubes observe the scintillating optical photons and each analog waveform is stored with the flash analog-to-digital converters. We present details of the data acquisition, processing, and data quality monitoring system. We also present two different trigger logics which are developed for the beam and self-trigger.

physics.ins-det↗

Performance of PMTs for the JSNS2 experiment

The JSNS$^{2}$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment aims to search for neutrino oscillations over a 24\,m short baseline at J-PARC. The JSNS$^{2}$ inner detector is filled with 17 tons of gadolinium-loaded liquid scintillator (LS) and both the intermediate $γ$-catcher and the optically separated outer veto are filled with un-loaded LS. Optical photons from scintillation are observed by 120 Photomultiplier Tubes (PMTs). A total of 130 PMTs for the JSNS2 experiment were both donated by other experiments and purchased from Hamamatsu. Donated PMTs were purchased around 10 years ago, therefore JSNS$^{2}$ did pre-calibration of the PMTs including the purchased PMTs. 123 PMTs demonstrated acceptable performance for the JSNS$^{2}$ experiment, and 120 PMTs were installed in the detector.

physics.ins-det↗

Development of a method for measuring rare earth elements in the environment for future experiments with gadolinium loaded detectors

Demand to use gadolinium (Gd) in detectors is increasing in the field of elementary particle physics, especially neutrino measurements and dark matter searches. Large amounts of Gd are used in these experiments. Therefore, to access the impacts of Gd onto the environments, it is becoming important to measure the baseline concentrations of Gd in the environments. The measurement of the baseline concentrations, however, is not easy due to interferences by other elements. In this paper, a method for measuring the concentrations of rare earth elements including Gd is proposed. In the method, an inductively coupled plasma-mass spectrometry is utilized after collecting the dissolved elements in chelating resin. Results of the ability to detect anomalous concentrations of rare earth elements in river water samples in the Kamioka and Toyama areas are also reported.

physics.ins-det↗

Technical Design Report (TDR): Searching for a Sterile Neutrino at J-PARC MLF (E56, JSNS2)

In this document, the technical details of the JSNS$^2$ (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) experiment are described. The search for sterile neutrinos is currently one of the hottest topics in neutrino physics. The JSNS$^2$ experiment aims to search for the existence of neutrino oscillations with $Δm^2$ near 1 eV$^2$ at the J-PARC Materials and Life Science Experimental Facility (MLF). A 1 MW beam of 3 GeV protons incident on a spallation neutron target produces an intense neutrino beam from muon decay at rest. Neutrinos come predominantly from $μ^+$ decay: $μ^{+} \to e^{+} + \barν_μ + ν_{e}$. The experiment will search for $\barν_μ$ to $\barν_{e}$ oscillations which are detected by the inverse beta decay interaction $\barν_{e} + p \to e^{+} + n$, followed by gammas from neutron capture on Gd. The detector has a fiducial volume of 17 tons and is located 24 meters away from the mercury target. JSNS$^2$ offers the ultimate direct test of the LSND anomaly. In addition to the sterile neutrino search, the physics program includes cross section measurements with neutrinos with a few 10's of MeV from muon decay at rest and with monochromatic 236 MeV neutrinos from kaon decay at rest. These cross sections are relevant for our understanding of supernova explosions and nuclear physics.

physics.ins-det↗

Status Report (22th J-PARC PAC): Searching for a Sterile Neutrino at J-PARC MLF (E56, JSNS2)

The JSNS$^2$ (J-PARC E56) experiment aims to search for a sterile neutrino at the J-PARC Materials and Life Sciences Experimental Facility (MLF). After the submission of a proposal to the J-PARC PAC, Stage-1 approval was granted to the JSNS$^2$ experiment on April 2015.This approval followed a series of background measurements which were performed in 2014. Recently, funding (the grant-in-aid for scientific research (S)) in Japan for building one 25~ton fiducial volume detector module was approved for the experiment. Therefore, we aim to start the experiment with one detector in JFY2018-2019. We are now working to produce precise cost estimates and schedule for construction, noting that most of the detector components can be produced within one year from the date of order. This will be reported at the next PAC meeting. In parallel to the detector construction schedule, JSNS$^2$ will submit a Technical Design report (TDR) to obtain the Stage-2 approval from the J-PARC PAC.The recent progress of the R$\&$D efforts towards this TDR are shown in this report. In particular, the R$\&$D status of the liquid scintillator, cosmic ray veto system, and software are shown. We have performed a test-experiment using 1.6~L of liquid scintillator at the 3rd floor of the MLF building in order to determine the identities of non-neutrino background particles coming to this detector location during the proton bunch. This is the so-called "MLF 2015AU0001" experiment. We briefly show preliminary results from this test-experiment.

physics.ins-det↗

Status Report for the 21th J-PARC PAC : Searching for a Sterile Neutrino at J-PARC MLF (J-PARC E56, JSNS2)

The JSNS2 (J-PARC E56) experiment aims to search for sterile neutrinos at the J-PARC Materials and Life Sciences Experimental Facility (MLF).After the submission of a proposal to the J-PARC PAC, stage-1 approval was granted to the JSNS2 experiment. The approval followed a series of background measurements which were performed in 2014. Subsequent for stage-1 approval, the JSNS2 collaboration has made continuous efforts to write a Technical Design Report (TDR).This TDR will include two major items as discussed in the previous status report for the 20th J-PARC PAC: (1) A realistic detector location (2) Well understood and realistic detector performance using simulation studies, primarily in consideration of fast neutron rejection. Since August we have been in discussions with MLF staff regarding an appropriate detector location. We are also in the process of setting up a Monte Carlo (MC) simulation framework in order to study detector's performance in realistic conditions. In addition, we have pursued hardware R&D work for the liquid scintillator (LS) and to improve the dynamic range of the 10" photomultiplier tubes (PMTs). The LS R&D works includes Cherenkov studies inside the LS, and a Pulse Shape Discrimination (PSD) study with a test-beam, performed at Tohoku University. We also estimate the PSD performance of a full-sized detector using a detailed MC simulation. In this status report, we describe progress on this work.

physics.ins-det↗

Status Report for the 20th J-PARC PAC : A Search for Sterile Neutrino at J-PARC MLF (J-PARC E56, JSNS2)

On April 2015, the J-PARC E56 (JSNS2: J-PARC Sterile Neutrino Search using neutrinos from J-PARC Spallation Neutron Source) experiment officially obtained stage-1 approval from J-PARC. We have since started to perform liquid scintillator R&D for improving energy resolution and fast neutron rejection. Also, we are studying Avalanche Photo-Diodes (SiPM) inside the liquid scintillator. In addition to the R&D work, a background measurement for the proton beam bunch timing using a small liquid scintillator volume was planned, and the safety discussions for the measurement have been done. This report describes the status of the R&D work and the background measurements, in addition to the milestones required before stage-2 approval.

physics.ins-det↗

On-site Background Measurements for the J-PARC E56 Experiment: A Search for Sterile Neutrino at J-PARC MLF

The J-PARC E56 experiment aims to search for sterile neutrinos at the J-PARC Materials and Life Science Experimental Facility (MLF). In order to examine the feasibility of the experiment, we measured the background rates of different detector candidate sites, which are located at the third floor of the MLF, using a detector consisting of plastic scintillators with a fiducial mass of 500 kg. The result of the measurements is described in this article. The gammas and neutrons induced by the beam as well as the backgrounds from the cosmic rays were measured.

physics.ins-det↗

Status Report (BKG measurement): A Search for Sterile Neutrino at J-PARC MLF

At the 17th J-PARC PAC, which was held on September 2013, we proposed the sterile neutrino search at J-PARC MLF. After reviewing the proposal, PAC recommended to have a background measurement at the detector's candidate site location in their report to investigate whether the background rates can be manageable for the real experiment or not. Therefore, we have performed the background measurements (MLF; 2013BU1301 test experiment) during the summer of 2014, also following the 18th J-PARC PAC recommendations, and the measurements results are described here.

physics.ins-det↗

Magnetic phase diagram of Sr$_{1-x}$Ca$_x$Co$_2$P$_2$

In order to study the phase diagram from a microscopic viewpoint, we have measured wTF- and ZF-$μ^+$SR spectra for the Sr$_{1-x}$Ca$_x$Co$_2$P$_2$ powder samples with $x=0$, 0.2, 0.4, 0.5, 0.6, 0.8, and 1. Due to a characteristic time window and spatial resolution of $μ^+$SR, the obtained phase diagram was found to be rather different from that determined by magnetization measurements. That is, as $x$ increases from 0, a Pauli-paramagnetic phase is observed even at the lowest $T$ measured (1.8~K) until $x=0.4$, then, a spin-glass like phase appears at $0.5\leq x\leq0.6$, and then, a phase with wide field distribution probably due to incommensurate AF order is detected for $x=0.8$, and finally, a commensurate $A$-type AF ordered phase (for $x=1$) is stabilized below $T_{\rm N}\sim80~$K. Such change is most likely reasonable and connected to the shrink of the $c$-axis length with $x$, which naturally enhances the magnetic interaction between the two adjacent Co planes.

cond-mat.str-el↗

Proposal: A Search for Sterile Neutrino at J-PARC Materials and Life Science Experimental Facility

We propose a definite search for sterile neutrinos at the J-PARC Materials and Life Science Experimental Facility (MLF). With the 3 GeV Rapid Cycling Synchrotron (RCS) and spallation neutron target, an intense neutrino beam from muon decay at rest (DAR) is available. Neutrinos come from μ+ decay, and the oscillation to be searched for is (anti νμ-> anti νe) which is detected by the inverse βdecay interaction (anti νe + p -> e+ + n), followed by a gamma from neutron capture. The unique features of the proposed experiment, compared with the LSND and experiments using horn focused beams, are; (1) The pulsed beam with about 600 ns spill width from J-PARC RCS and muon long lifetime allow us to select neutrinos from μDAR only. (2) Due to nuclear absorption of π- and μ-, neutrinos from μ- decay are suppressed to about the $10^{-3}$ level. (3) Neutrino cross sections are well known. The inverse βdecay cross section is known to be a few percent accuracy. (4) The neutrino energy can be calculated from positron energy by adding ~1.8 MeV. (5) The anti νμand νe fluxes have different and well defined spectra. This allows us to separate oscillated signals from those due to μ- decay contamination. We propose to proceed with the oscillation search in steps since the region of Δm^2 to be searched can be anywhere between sub-eV^2 to several tens of eV^2. We start to examine the large Δm^2 region, which can be done with short baseline at first. At close distance to the MLF target gives a high neutrino flux, and allows us to use relatively small detector. If no definitive positive signal is found, a future option exists to cover small Δm^2 region. This needs a relatively long baseline and requires a large detector to compensate for the reduced neutrino flux.

physics.ins-det↗

Neutron imaging detector based on the muPIC micro-pixel chamber

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.

physics.ins-det↗

Study of Light Scalar Meson Structure in $D_1$ decay

We study the quark structure of the sigma meson through the decay of $D_1(2430)$ meson by constructing an effective Lagrangian for charmed mesons interacting with light mesons based on the chiral symmetry and heavy quark symmetry. Within the linear realization of the chiral symmetry, we include the P-wave charmed mesons ($D_1(2430)$, $D_0(2400)$) as the chiral partners of ($D^\ast$, $D$), and the light scalar mesons as the chiral partner of the pseudoscalar mesons. In the light meson sector, both the $q\bar{q}$ and $qq\bar{q}\bar{q}$ states are incorporated respecting their different U(1)$_A$ transformation properties. We predict the $D_1 \to Dππ$ decay width with two pions in the $I=0,\,l=0$ channel, which can be tested in the future experiment. We find that the width increases with the percentage of the $q\bar{q}$ content in the sigma meson.

hep-ph↗

Integrating out Holographic QCD back to Hidden Local Symmetry

We develop a previously proposed gauge-invariant method to integrate out infinite towers of vector and axialvector mesons arising as Kaluza-Klein (KK) modes in a class of holographic models of QCD (HQCD). We demonstrate that HQCD can be reduced to the chiral perturbation theory (ChPT) with the hidden local symmetry (HLS) (so-called HLS-ChPT) having only the lowest KK mode identified as the HLS gauge boson, and the Nambu-Goldstone bosons. The ${\cal O} (p^4)$ terms in the HLS-ChPT are completely determined by integrating out infinite towers of vector/axialvector mesons in HQCD: Effects of higher KK modes are fully included in the coefficients. As an example, we apply our method to the Sakai-Sugimoto model.

hep-ph↗

Enhancement of quark number susceptibility with an alternative pattern of chiral symmetry breaking in dense matter

We explore a possible phase where chiral $SU(2)_L \times SU(2)_R$ symmetry is spontaneously broken while its center $Z_2$ symmetry remains unbroken and its consequence on thermal quantities. In this phase, chiral symmetry breaking is driven by a quartic quark condensate although a bilinear quark condensate vanishes. A Ginzburg-Landau free energy leads to a new tricritical point (TCP) between the $Z_2$ broken and unbroken phases. Furthermore, a critical point can appear even in the chiral limit where explicit breaking is turned off, instead of a TCP at which restoration of chiral and its center symmetries takes place simultaneously. The net quark number density exhibits an abrupt change near the restoration of the center symmetry rather than that of the chiral symmetry. Hadron masses in possible phases are also studied in a linear sigma model. We show that, in the $Z_2$ symmetric phase, the $\bar{q}q$-type scalar meson with zero isospin I=0 splits from the $\bar{q}q$-type pseudoscalar meson with I=1.

hep-ph↗

A novel spectral broadening from vector--axial-vector mixing in dense matter

The presence of baryonic matter leads to the mixing between transverse $ρ$ and $a_1$ mesons through a set of $ωρa_1$-type interactions, which results in the modification to the dispersion relation. We show that a clear enhancement of the vector spectral function appears below $\sqrt{s}=m_ρ$ for small three-momenta of the $ρ$ meson, and thus the vector spectrum exhibits broadening. We also discuss its relevance to dilepton measurements.

hep-ph↗