SearcharxivSearch

arXiv subjects

M. Harrison

Publications and source records attributed to M. Harrison.

11 recordsLinked to original sources

Probing Nuclear Effects with Transverse Kinematic Imbalance in Muon-neutrino Induced Charged-Current $\pi^0$ Production on Argon with the MicroBooNE Detector

Neutrino-nucleus cross-section measurements are needed to improve interaction modeling and to enable precision neutrino oscillation measurements in upcoming experiments such as the Deep Underground Neutrino Experiment (DUNE), Hyper-Kamiokande, and the Short-Baseline Neutrino program. Baryon-resonance neutrino interactions constitute a dominant contribution near the peak of the DUNE neutrino energy spectrum. We present the first measurement of muon neutrino charged-current resonance-like interactions on argon using transverse kinematic imbalance variables with the MicroBooNE detector. These observables are highly sensitive to the modeling of final-state interactions. This measurement probes kinematic imbalances using the reconstructed momenta of the muon, leading proton, and neutral pion. A comprehensive characterization of the $\pi^0$-proton final state is presented; however, none of the models considered are able to simultaneously reproduce all measured observables.

hep-ex

First Measurement of Sub-GeV $\nu_{\mu}$ Charged-Current Coherent Pion Production on Argon in MicroBooNE

We report a measurement of the charged-current coherent pion production cross section on argon using the MicroBooNE liquid argon time projection chamber exposed to the Booster Neutrino Beam at Fermilab. The measurement uses the MicroBooNE data set corresponding to $1.26 \times 10^{21}$ protons on target with a mean neutrino energy of $0.8$~GeV. The flux-averaged cross section is measured to be $(9.1 \pm 1.2_{\text{stat}} \pm 1.2_\text{syst}) \times 10^{-40}\,\text{cm}^2/\text{Ar}$. This result represents the first measurement of charged-current coherent pion production on argon at sub-GeV neutrino energies. Due to its clean two-body kinematics, where the neutrino interacts coherently with the entire nucleus producing a forward muon and pion with no nuclear breakup, this process provides a useful tool for constraining neutrino flux uncertainties in current and future oscillation experiments such as DUNE.

hep-ex

Characterizing the energy resolution of the MicroBooNE LArTPC at the MeV scale using monoenergetic features of $^{208}$Tl decays

A detailed understanding of the capabilities and fidelity of low-energy reconstruction is crucial for taking advantage of MeV-scale neutrino physics opportunities in liquid argon time projection chambers (LArTPCs). This study presents a measurement of the resolution of reconstructed energy in the MicroBooNE LArTPC at $\approx 1.5$ MeV. The characterization is performed using monoenergetic signals generated by $2.614$ MeV $\gamma$-rays from $^{208}$Tl decays undergoing pair production in the detector. The resolution is found to be ($7.52 \pm 0.78 \text{(stat)} \pm 0.92 \text{(syst)}$)%. This value is consistent with the MicroBooNE simulation prediction of ($9.70 \pm 0.65 \text{(stat)}$)% at the $1.6 \sigma$ level. This study represents the first ever measurement of LArTPC energy resolution at the MeV scale and provides a pathway for monoenergetic energy calibrations in future experiments using LArTPC detectors.

physics.ins-det

Improved muon energy estimation using a detailed model of multiple Coulomb scattering in the MicroBooNE LArTPC

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1% and the estimated resolution varies from 4.3% to 10% as muon energy increases from 0.1 GeV to 2 GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2 GeV, the estimated bias is less than 2% and the estimated resolution varies from 7% to 17% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE, which achieves twice as large a resolution as well as a bias of 20% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

hep-ex

Scintillation light calibrations, systematic uncertainties, and triggering efficiency in the MicroBooNE detector

Scintillation light, produced alongside ionisation charge from particle interactions, plays a critical role in liquid argon time projection chamber (LArTPC) detectors. A detailed understanding of its production and detection mechanisms is essential for robust calibration, systematic uncertainty evaluation, and physics analysis. This article describes the MicroBooNE light simulation, light-based triggering schemes, photomultiplier tube gain calibration, light response stability, and light-based systematic uncertainties over the course of five years of data collection. In addition, we present a measurement of scintillation light triggering efficiency, focusing on the lowest-light regime relevant to rare-event searches and low-energy neutrino interactions. Finally, we discuss two notable observations in MicroBooNE's data, both reported here for the first time: an approximately 50% decline in MicroBooNE's light yield over time, concentrated in the first two years of running; and a higher than expected O(200 kHz) rate of single photoelectron noise. The results presented provide an important benchmark of long-term light detection performance in LArTPC neutrino detectors.

physics.ins-det

Measurements of the electron neutrino-argon differential cross section without pions in the final state in MicroBooNE

We present a new measurement of the electron neutrino charged current cross section on argon without pions in the final state. This measurement uses the full MicroBooNE booster neutrino beam dataset of $1.3\times 10^{21}$ protons on target collected at Fermi National Accelerator Laboratory. Events are considered both with and without protons above the kinetic energy visibility threshold. Differential cross sections are extracted in proton and electron kinematics, including energy and angle relative to the neutrino beam direction. The relationship between the hadronic and leptonic systems is explored through the angle between the proton and electron directions. The resulting cross sections are compared to a variety of available generator predictions using different models of neutrino interactions. We find good agreement with most models in lepton kinematics and some discrepancies in the hadronic system modeling, particularly in proton angle.

hep-ex

Demonstration and performance of an online data selection algorithm for liquid argon time projection chambers using MicroBooNE

The MicroBooNE detector is a liquid argon time projection chamber (LArTPC) that produces three-dimensional images of particle interactions using ionization charge collected by anode wire plane arrays and scintillation light collected by a light detection system. In addition to testing long-standing experimental neutrino anomalies and performing measurements of neutrino interactions with argon nuclei using the Fermilab Booster Neutrino Beam, MicroBooNE aims to develop methodologies for rare beyond the Standard Model and off-beam physics searches. Looking ahead to the upcoming Deep Underground Neutrino Experiment (DUNE), with MicroBooNE serving as a valuable testbed, achieving high sensitivity and livetime for off-beam physics while satisfying data processing and storage constraints will require data-driven, intelligent, and online or real-time data selection techniques. These techniques are essential for reducing data rates and preserving rare signals with high accuracy. In this paper, we describe a fast data selection algorithm suitable for online execution to identify electrons from stopping cosmic ray muons in the MicroBooNE detector utilizing ionization charge information, and present its performance. This represents the first demonstration of online data selection in a LArTPC using real data and charge information exclusively and provides an important proof-of-principle for applying such techniques to other LArTPC experiments such as the Short-Baseline Near Detector and DUNE.

hep-ex

Measured gain suppression in FBK LGADs with different active thicknesses

In recent years, the gain suppression mechanism has been studied for large localized charge deposits in Low-Gain Avalanche Detectors (LGADs). LGADs are a thin silicon detector with a highly doped gain layer that provides moderate internal signal amplification. Using the CENPA Tandem accelerator at the University of Washington, the response of LGADs with different thicknesses to MeV-range energy deposits from a proton beam were studied. Three LGAD prototypes of 50~$\mu$m, 100~$\mu$m, 150~$\mu$m were characterized. The devices' gain was determined as a function of bias voltage, incidence beam angle, and proton energy. This study was conducted in the scope of the PIONEER experiment, an experiment proposed at the Paul Scherrer Institute to perform high-precision measurements of rare pion decays. LGADs are considered for the active target (ATAR) and energy linearity is an important property for particle ID capabilities.

physics.ins-det

On the Superiority of the University of Arizona's Physics Club

We present an analysis on Physics Club's supremacy over the Astronomy Club at the University of Arizona. Through a thorough investigation of each club's history and content, and subsequent diligent calculations, we have proven without a doubt that the Physics Club is superior to Astronomy Club.

physics.pop-ph

Preliminary Measurements for a Sub-Femtosecond Electron Bunch Length Diagnostic

With electron beam durations down to femtoseconds and sub-femtoseconds achievable in current state-of-the-art accelerators, longitudinal bunch length diagnostics with resolution at the attosecond level are required. In this paper, we present such a novel measurement device which combines a high power laser modulator with an RF deflecting cavity in the orthogonal direction. While the laser applies a strong correlated angular modulation to a beam, the RF deflector ensures the full resolution of this streaking effect across the bunch hence recovering the temporal beam profile with sub-femtosecond resolution. Preliminary measurements to test the key components of this concept were carried out at the Accelerator Test Facility (ATF) at Brookhaven National Laboratory recently, the results of which are presented and discussed here. Moreover, a possible application of the technique for novel accelerator schemes is examined based on simulations with the particle-tracking code elegant and our beam profile reconstruction tool.

physics.acc-ph

A study of RHIC crystal collimation

The Relativistic Heavy Ion Collider (RHIC) will experience increasing longitudinal and transverse heavy ion emittances, mostly due to intra-beam scattering (IBS). The experiments in RHIC are expected to not only have reduced luminosities due to IBS but also an unwanted beam halo. Primary betatron collimators will be used to remove the large amplitude particles. The efficiency of the primary collimator in RHIC depends very much on the alignment of the jaws which needs to be within few micro-radians for the best conditions. As proposed by V. Biryukov bent crystals could be used to improve the efficiency of an existing collimation system by installing them upstream of the collimator jaws. Bent crystals have been successfully used in SPS, Protvino and Fermilab for extraction of the beam particles channeled through them. This study examines possible improvements of the primary collimator system for heavy ions at RHIC by use of bent crystals. Bent crystals will reduce the collimator jaws alignment requirement and will increase collimator efficiency thereby reducing detector background.

hep-ex