SearcharxivSearch

arXiv subjects

M. Hrabovsky

Publications and source records attributed to M. Hrabovsky.

7 recordsLinked to original sources

Analysis of commissioning data from SST-1M : A Prototype of Single-Mirror Small Size Telescope

SST-1M is a prototype of a single-mirror Small Size Telescope developed by a consortium of institutes from Poland, Switzerland and the Czech Republic. With a wide field of view of 9 degrees, SST-1Ms are designed to detect gamma-rays in the energy range between 1 and 300 TeV. The design of the SST-1M follows the Davies-Cotton concept, with a 9.42m2 multi-segment mirror. SST-1M is equipped with DigiCam camera, which features a fully digital readout and trigger system using 250 MHz ADC, and a compact Photo-Detector Plane (PDP) composed of 1296 pixels, each made of a hexagonal light guide coupled to silicone photomultipliers (SiPM). Two SST-1M telescopes are currently being commissioned at the Ondrejov Observatory in the Czech Republic, where they are successfully observing Cerenkov events in stereo. This contribution will present an overview of calibration strategies and performance evaluation based on data collected at the observatory.

astro-ph.IM

Mono and stereo performance of the two SST-1M telescope prototypes

The Single-Mirror Small-Sized Telescope, or SST-1M, was originally developed as a prototype of a small-sized telescope for CTA, designed to form an array for observations of gamma-ray-induced atmospheric showers for energies above 3 TeV. A pair of SST-1M telescopes is currently being commissioned at the Ondrejov Observatory in the Czech Republic, and the telescope capabilities for mono and stereo observations are being tested in better astronomical conditions. The final location for the telescopes will be decided based on these tests. In this contribution, we present a data analysis pipeline called sst1mpipe, and the performance of the telescopes when working independently and in a stereo regime.

astro-ph.IM

The First Full-Scale Prototypes of the Fluorescence detector Array of Single-pixel Telescopes

The Fluorescence detector Array of Single-pixel Telescopes (FAST) is a design concept for a next-generation UHECR observatory, addressing the requirements for a large-area, low-cost detector suitable for measuring the properties of ultra-high energy cosmic rays (UHECRs), having energies exceeding $10^{19.5}$\,eV, with an unprecedented aperture. We have developed a full-scale prototype consisting of four 200\,mm diameter photo-multiplier tubes at the focus of a segmented mirror of 1.6\,m in diameter. In October 2016, September 2017, and September 2018 we installed three such prototypes at the Black Rock Mesa site of the Telescope Array experiment in central Utah, USA. All three telescopes have been steadily taking data since installation. We report on the design and installation of these prototypes, and present some preliminary results, including measurements of artificial light sources, distant ultraviolet lasers, and UHECRs. Furthermore, we discuss some additional uses for these simplified low-cost fluorescence telescopes, including the facilitation of a systematic comparison of the transparency of the atmosphere above the Telescope Array experiment and the Pierre Auger Observatory, a study of the systematic uncertainty associated with the existing fluorescence detectors of these two experiments, and a cross-calibration of their energy and $X_{\text{max}}$ scales.

astro-ph.HE

Detection of ultra-high energy cosmic ray showers with a single-pixel fluorescence telescope

We present a concept for large-area, low-cost detection of ultra-high energy cosmic rays (UHECRs) with a Fluorescence detector Array of Single-pixel Telescopes (FAST), addressing the requirements for the next generation of UHECR experiments. In the FAST design, a large field of view is covered by a few pixels at the focal plane of a mirror or Fresnel lens. We report first results of a FAST prototype installed at the Telescope Array site, consisting of a single 200 mm photomultiplier tube at the focal plane of a 1 m$^2$ Fresnel lens system taken from the prototype of the JEM-EUSO experiment. The FAST prototype took data for 19 nights, demonstrating remarkable operational stability. We detected laser shots at distances of several kilometres as well as 16 highly significant UHECR shower candidates.

astro-ph.IM

AtmoHEAD 2013 workshop / Atmospheric Monitoring for High-Energy Astroparticle Detectors

A 3-day international workshop on atmospheric monitoring and calibration for high-energy astroparticle detectors, with a view towards next-generation facilities. The atmosphere is an integral component of many high-energy astroparticle detectors. Imaging atmospheric Cherenkov telescopes and cosmic-ray extensive air shower detectors are the two instruments driving the rapidly evolving fields of very-high- and ultra-high-energy astrophysics. In these instruments, the atmosphere is used as a giant calorimeter where cosmic rays and gamma rays deposit their energy and initiate EASs; it is also the medium through which the resulting Cherenkov light propagates. Uncertainties in real-time atmospheric conditions and in the fixed atmospheric models typically dominate all other systematic errors. With the improved sensitivity of upgraded IACTs such as H.E.S.S.-II and MAGIC-II and future facilities like the Cherenkov Telescope Array (CTA) and JEM-EUSO, statistical uncertainties are expected to be significantly reduced, leaving the atmosphere as the limiting factor in the determination of astroparticle spectra. Varying weather conditions necessitate the development of suitable atmospheric monitoring to be integrated in the overall instrument calibration, including Monte Carlo simulations. With expertise distributed across multiple collaborations and scientific domains, an interdisciplinary workshop is being convened to advance progress on this critical and timely topic.

astro-ph.IM

Precise measurement of the absolute fluorescence yield of the 337 nm band in atmospheric gases

A measurement of the absolute fluorescence yield of the 337 nm nitrogen band, relevant to ultra-high energy cosmic ray (UHECR) detectors, is reported. Two independent calibrations of the fluorescence emission induced by a 120 GeV proton beam were employed: Cherenkov light from the beam particle and calibrated light from a nitrogen laser. The fluorescence yield in air at a pressure of 1013 hPa and temperature of 293 K was found to be $Y_{337} = 5.61\pm 0.06_{stat} \pm 0.21_{syst}$ photons/MeV. When compared to the fluorescence yield currently used by UHECR experiments, this measurement improves the uncertainty by a factor of three, and has a significant impact on the determination of the energy scale of the cosmic ray spectrum.

astro-ph.IM

Measurement of the Crab Flux Above 60 GeV with the CELESTE Cherenkov Telescope

We have converted the former solar electrical plant THEMIS (French Pyrenees) into an atmospheric Cherenkov detector called CELESTE, which records gamma rays above 30 GeV (7E24 Hz). Here we present the first sub-100 GeV detection by a ground based telescope of a gamma ray source, the Crab nebula, in the energy region between satellite measurements and imaging atmospheric Cherenkov telescopes. At our analysis threshold energy of 60 +/- 20 GeV we measure a gamma ray rate of 6.1 +/- 0.8 per minute. Allowing for 30% systematic uncertainties and a 30% error on the energy scale yields an integral gamma ray flux of I(E>60 GeV) = 6.2^{+5.3}_{-2.3} E-6 photons m^-2 s^-1. The analysis methods used to obtain the gamma ray signal from the raw data are detailed. In addition, we determine the upper limit for pulsed emission to be <12% of the Crab flux at the 99% confidence level, in the same energy range. Our result indicates that if the power law observed by EGRET is attenuated by a cutoff of form e^{-E/E_0} then E_0 < 26 GeV. This is the lowest energy probed by a Cherenkov detector and leaves only a narrow range unexplored beyond the energy range studied by EGRET.

astro-ph