SearcharxivSearch

arXiv subjects

M. Huhtinen

Publications and source records attributed to M. Huhtinen.

3 recordsLinked to original sources

High-energy proton induced damage in Lead Tungstate calorimeter crystals

Eight production quality PbWO4 crystals of CMS have been irradiated in a 20 GeV/c proton beam up to fluences of 5.4E13cm-2. The damage recovery in these crystals has been followed for over a year. Comparative irradiations with 60Co photons have been performed on seven other crystals using a dose rate of 1 kGy/h. In proton irradiated crystals the light transmission band-edge shifts and the induced absorption length is proportional to the inverse of the 4th power of the wavelength. In gamma-irradiated crystals the band-edge does not shift but formation of absorption bands is seen clearly. The absorption length induced by gamma-radiation in crystals verified to have excellent radiation hardness, saturates at a level below 0.5 m-1. In the case of protons, we observe no correlation with the pre-characterised radiation hardness of the crystals and the induced absorption increases linearly with fluence. After a fluence of 5E13 cm-2, an induced absorption length of approx. 15m-1 is seen with no sign of saturation. These observations provide strong evidence that high-energy protons create damage that cannot be reproduced with gamma-irradiation. However, these hadronic effects manifest themselves only at integral fluences well beyond 1E12cm-2 and most likely would escape undetected at lower fluences. A large fraction of the damage, both in proton- and gamma-irradiated crystals, is either stable or recovers very slowly.

physics.ins-det

First results on radiation damage in PbWO4 crystals exposed to a 20 GeV/c proton beam

We have exposed seven full length production quality crystals of the electromagnetic calorimeter (ECAL) of the CMS detector to a 20 GeV/c proton beam at the CERN PS accelerator. The exposure was done at fluxes of 10**12 p/cm**2/h and 10**13 p/cm**2/h and integral fluences of 10**12 p/cm**2 and 10**13 p/cm**2 were reached at both rates. The light transmission of the crystals was measured after irradiation and suitable cooling time for induced radioactivity to decrease to a safe level. First results of these measurements are shown. The possible damage mechanisms are discussed and simulations based on one possible model are presented. The implications for long-term operation of CMS are discussed and it is shown that in the whole barrel and at least most of the ECAL endcap hadron damage alone - even if cumulative - should not cause the crystals to fail the CMS specification of an induced absorption coefficient muIND < 1.5 /m during the first 10 years of LHC operation.

physics.ins-det

Wire scanners in low energy accelerators

Fast wire scanners are today considered as part of standard instrumentation in high energy synchrotrons. The extension of their use to synchrotrons working at lower energies, where Coulomb scattering can be important and the transverse beam size is large, introduces new complications considering beam heating of the wire, composition of the secondary particle shower and geometrical consideration in the detection set-up. A major problem in treating these effects is that the creation of secondaries in a thin carbon wire by a energetic primary beam is difficult to describe in an analytical way. We are here presenting new results from a full Monte Carlo simulation of this process yielding information on heat deposited in the wire, particle type and energy spectrum of secondaries and angular dependence as a function of primary beam energy. The results are used to derive limits for the use of wire scanners in low energy accelerators.

physics.acc-ph