SearcharxivSearch

arXiv subjects

M. I. Lopes

Publications and source records attributed to M. I. Lopes.

At least 19 recordsLinked to original sources

Transforming a rare event search into a not-so-rare event search in real-time with deep learning-based object detection

Deep learning-based object detection algorithms enable the simultaneous classification and localization of any number of objects in image data. Many of these algorithms are capable of operating in real-time on high resolution images, attributing to their widespread usage across many fields. We present an end-to-end object detection pipeline designed for real-time rare event searches for the Migdal effect, using high-resolution image data from a state-of-the-art scientific CMOS camera in the MIGDAL experiment. The Migdal effect in nuclear scattering, crucial for sub-GeV dark matter searches, has yet to be experimentally confirmed, making its detection a primary goal of the MIGDAL experiment. Our pipeline employs the YOLOv8 object detection algorithm and is trained on real data to enhance the detection efficiency of nuclear and electronic recoils, particularly those exhibiting overlapping tracks that are indicative of the Migdal effect. When deployed online on the MIGDAL readout PC, we demonstrate our pipeline to process and perform the rare event search on 2D image data faster than the peak 120 frame per second acquisition rate of the CMOS camera. Applying these same steps offline, we demonstrate that we can reduce a sample of 20 million camera frames to around 1000 frames while maintaining nearly all signal that YOLOv8 is able to detect, thereby transforming a rare search into a much more manageable search. Our studies highlight the potential of pipelines similar to ours significantly improving the detection capabilities of experiments requiring rapid and precise object identification in high-throughput data environments.

hep-ex

Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity

Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 keV and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.

physics.ins-det

New constraints on ultraheavy dark matter from the LZ experiment

Searches for dark matter with liquid xenon time projection chamber experiments have traditionally focused on the region of the parameter space that is characteristic of weakly interacting massive particles, ranging from a few GeV/$c^2$ to a few TeV/$c^2$. Models of dark matter with a mass much heavier than this are well motivated by early production mechanisms different from the standard thermal freeze-out, but they have generally been less explored experimentally. In this work, we present a re-analysis of the first science run (SR1) of the LZ experiment, with an exposure of $0.9$ tonne$\times$year, to search for ultraheavy particle dark matter. The signal topology consists of multiple energy deposits in the active region of the detector forming a straight line, from which the velocity of the incoming particle can be reconstructed on an event-by-event basis. Zero events with this topology were observed after applying the data selection calibrated on a simulated sample of signal-like events. New experimental constraints are derived, which rule out previously unexplored regions of the dark matter parameter space of spin-independent interactions beyond a mass of 10$^{17}$ GeV/$c^2$.

hep-ex

Reflection of a Diffuser in a Liquid Interface

We present a novel method, based on the Saunderson corrections, to predict the reflectance between a liquid interface and a dielectric diffuser. In this method, the diffuse properties of the dielectric are characterized using a single parameter, the multiple-scattering albedo, which is the same irrespective of being in contact with air or liquid. We tested this method using an apparatus based on a total integrating sphere capable of measuring reflectance in both liquid and gas interfaces across various wavelengths of light. We observed that the difference in the value of the multiple-scattering albedo between the sphere full of liquid and empty was less than 0.9$\times 10^{-3}$, with the average difference normalized to the respective uncertainty of only 0.7. These results confirm the reliability of our method and its potential for use in a wide range of practical applications.

physics.optics

The MIGDAL experiment: Measuring a rare atomic process to aid the search for dark matter

We present the Migdal In Galactic Dark mAtter expLoration (MIGDAL) experiment aiming at the unambiguous observation and study of the so-called Migdal effect induced by fast-neutron scattering. It is hoped that this elusive atomic process can be exploited to enhance the reach of direct dark matter search experiments to lower masses, but it is still lacking experimental confirmation. Our goal is to detect the predicted atomic electron emission which is thought to accompany nuclear scattering with low, but calculable, probability, by deploying an Optical Time Projection Chamber filled with a low-pressure gas based on CF$_4$. Initially, pure CF$_4$ will be used, and then in mixtures containing other elements employed by leading dark matter search technologies -- including noble species, plus Si and Ge. High resolution track images generated by a Gas Electron Multiplier stack, together with timing information from scintillation and ionisation readout, will be used for 3D reconstruction of the characteristic event topology expected for this process -- an arrangement of two tracks sharing a common vertex, with one belonging to a Migdal electron and the other to a nuclear recoil. Different energy-loss rate distributions along both tracks will be used as a powerful discrimination tool against background events. In this article we present the design of the experiment, informed by extensive particle and track simulations and detailed estimations of signal and background rates. In pure CF$_4$ we expect to observe 8.9 (29.3) Migdal events per calendar day of exposure to an intense D-D (D-T) neutron generator beam at the NILE facility located at the Rutherford Appleton Laboratory (UK). With our nominal assumptions, 5$σ$ median discovery significance can be achieved in under one day with either generator.

hep-ex

Fast and Flexible Analysis of Direct Dark Matter Search Data with Machine Learning

We present the results from combining machine learning with the profile likelihood fit procedure, using data from the Large Underground Xenon (LUX) dark matter experiment. This approach demonstrates reduction in computation time by a factor of 30 when compared with the previous approach, without loss of performance on real data. We establish its flexibility to capture non-linear correlations between variables (such as smearing in light and charge signals due to position variation) by achieving equal performance using pulse areas with and without position-corrections applied. Its efficiency and scalability furthermore enables searching for dark matter using additional variables without significant computational burden. We demonstrate this by including a light signal pulse shape variable alongside more traditional inputs such as light and charge signal strengths. This technique can be exploited by future dark matter experiments to make use of additional information, reduce computational resources needed for signal searches and simulations, and make inclusion of physical nuisance parameters in fits tractable.

astro-ph.CO

A machine learning-based methodology for pulse classification in dual-phase xenon time projection chambers

Machine learning techniques are now well established in experimental particle physics, allowing detector data to be analysed in new and unique ways. The identification of signals in particle observatories is an essential data processing task that can potentially be improved using such methods. This paper aims at exploring the benefits that a dedicated machine learning approach might provide to the classification of signals in dual-phase noble gas time projection chambers. A full methodology is presented, from exploratory data analysis using Gaussian mixture models and feature importance ranking to the construction of dedicated predictive models based on standard implementations of neural networks and random forests, validated using unlabelled simulated data from the LZ experiment as a proxy to real data. The global classification accuracy of the predictive models developed in this work is estimated to be >99.0%, which is an improvement over conventional algorithms tested with the same data. The results from the clustering analysis were also used to identify anomalies in the data caused by miscalculated signal properties, showing that this methodology can also be used for data monitoring.

physics.ins-det

Constraints on Effective Field Theory Couplings Using 311.2 days of LUX Data

We report here the results of an Effective Field Theory (EFT) WIMP search analysis using LUX data. We build upon previous LUX analyses by extending the search window to include nuclear recoil energies up to $\sim$180 keV$_{nr}$, requiring a reassessment of data quality cuts and background models. In order to use a binned Profile Likelihood statistical framework, the development of new analysis techniques to account for higher-energy backgrounds was required. With a 3.14$\times10^4$ kg$\cdot$day exposure using data collected between 2014 and 2016, we set 90\% C.L. exclusion limits on non-relativistic EFT WIMP couplings to neutrons and protons, providing the most stringent constraints on a significant fraction of the possible EFT WIMP interactions. Additionally, we report world-leading exclusion limits on inelastic EFT WIMP-nucleon recoils.

astro-ph.CO

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

astro-ph.IM

Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers

We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of $\sim$100 keV, we observe an electronic recoil background acceptance of $<10^{-5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is ${(7.3\pm0.6)\times10^{-4}}$, which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.

physics.ins-det

Improving sensitivity to low-mass dark matter in LUX using a novel electrode background mitigation technique

This paper presents a novel technique for mitigating electrode backgrounds that limit the sensitivity of searches for low-mass dark matter (DM) using xenon time projection chambers. In the LUX detector, signatures of low-mass DM interactions would be very low energy ($\sim$keV) scatters in the active target that ionize only a few xenon atoms and seldom produce detectable scintillation signals. In this regime, extra precaution is required to reject a complex set of low-energy electron backgrounds that have long been observed in this class of detector. Noticing backgrounds from the wire grid electrodes near the top and bottom of the active target are particularly pernicious, we develop a machine learning technique based on ionization pulse shape to identify and reject these events. We demonstrate the technique can improve Poisson limits on low-mass DM interactions by a factor of $2$-$7$ with improvement depending heavily on the size of ionization signals. We use the technique on events in an effective $5$ tonne$\cdot$day exposure from LUX's 2013 science operation to place strong limits on low-mass DM particles with masses in the range $m_χ\in0.15$-$10$ GeV. This machine learning technique is expected to be useful for near-future experiments, such as LZ and XENONnT, which hope to perform low-mass DM searches with the stringent background control necessary to make a discovery.

hep-ex

Investigation of background electron emission in the LUX detector

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events in the low energy region. While this background negatively impacts detector performance in various ways, its origins have only been partially studied. In this paper we report a systematic investigation of the electron pathologies observed in the LUX dark matter experiment. We characterize different electron populations based on their emission intensities and their correlations with preceding energy depositions in the detector. By studying the background under different experimental conditions, we identified the leading emission mechanisms, including photoionization and the photoelectric effect induced by the xenon luminescence, delayed emission of electrons trapped under the liquid surface, capture and release of drifting electrons by impurities, and grid electron emission. We discuss how these backgrounds can be mitigated in LUX and future xenon-based dark matter experiments.

physics.ins-det

Search for two neutrino double electron capture of $^{124}$Xe and $^{126}$Xe in the full exposure of the LUX detector

Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidence of a signal was observed, allowing us to set 90\% C.L. lower limits for the half-lives of these decays of $2.0\times10^{21}$~years for $^{124}$Xe and $1.9\times10^{21}$~years for $^{126}$Xe.

nucl-ex

Projected sensitivity of the LUX-ZEPLIN experiment to the $0νββ$ decay of $^{136}$Xe

The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of $^{136}$Xe is projected to be 1.06$\times$10$^{26}$ years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with $^{136}$Xe at 1.06$\times$10$^{27}$ years.

nucl-ex

An Effective Field Theory Analysis of the First LUX Dark Matter Search

The Large Underground Xenon (LUX) dark matter search was a 250-kg active mass dual-phase time projection chamber that operated by detecting light and ionization signals from particles incident on a xenon target. In December 2015, LUX reported a minimum 90% upper C.L. of 6e-46 cm^2 on the spin-independent WIMP-nucleon elastic scattering cross section based on a 1.4e4 kg*day exposure in its first science run. Tension between experiments and the absence of a definitive positive detection suggest it would be prudent to search for WIMPs outside the standard spin-independent/spin-dependent paradigm. Recent theoretical work has identified a complete basis of 14 independent effective field theory (EFT) operators to describe WIMP-nucleon interactions. In addition to spin-independent and spin-dependent nuclear responses, these operators can produce novel responses such as angular-momentum-dependent and spin-orbit couplings. Here we report on a search for all 14 of these EFT couplings with data from LUX's first science run. Limits are placed on each coupling as a function of WIMP mass.

astro-ph.CO

Improved Modeling of $β$ Electronic Recoils in Liquid Xenon Using LUX Calibration Data

We report here methods and techniques for creating and improving a model that reproduces the scintillation and ionization response of a dual-phase liquid and gaseous xenon time-projection chamber. Starting with the recent release of the Noble Element Simulation Technique (NEST v2.0), electronic recoil data from the $β$ decays of ${}^3$H and ${}^{14}$C in the Large Underground Xenon (LUX) detector were used to tune the model, in addition to external data sets that allow for extrapolation beyond the LUX data-taking conditions. This paper also presents techniques used for modeling complicated temporal and spatial detector pathologies that can adversely affect data using a simplified model framework. The methods outlined in this report show an example of the robust applications possible with NEST v2.0, while also providing the final electronic recoil model and detector parameters that will used in the new analysis package, the LUX Legacy Analysis Monte Carlo Application (LLAMA), for accurate reproduction of the LUX data. As accurate background reproduction is crucial for the success of rare-event searches, such as dark matter direct detection experiments, the techniques outlined here can be used in other single-phase and dual-phase xenon detectors to assist with accurate ER background reproduction.

physics.ins-det

Extending light WIMP searches to single scintillation photons in LUX

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.

astro-ph.CO

First direct detection constraint on mirror dark matter kinetic mixing using LUX 2013 data

We present the results of a direct detection search for mirror dark matter interactions, using data collected from the Large Underground Xenon experiment during 2013, with an exposure of 95 live-days $\times$ 118 kg. Here, the calculations of the mirror electron scattering rate in liquid xenon take into account the shielding effects from mirror dark matter captured within the Earth. Annual and diurnal modulation of the dark matter flux and atomic shell effects in xenon are also accounted for. Having found no evidence for an electron recoil signal induced by mirror dark matter interactions we place an upper limit on the kinetic mixing parameter over a range of local mirror electron temperatures between 0.1 and 0.6 keV. This limit shows significant improvement over the previous experimental constraint from orthopositronium decays and significantly reduces the allowed parameter space for the model. We exclude mirror electron temperatures above 0.3 keV at a 90% confidence level, for this model, and constrain the kinetic mixing below this temperature.

hep-ex