SearcharxivSearch

arXiv subjects

M. Incurvati

Publications and source records attributed to M. Incurvati.

3 recordsLinked to original sources

Design considerations for future DAFNE upgrade

The Frascati F-Factory DAFNE has been delivering luminosity to the KLOE, DEAR and FINUDA experiments since year 2000. Since April 2004 the KLOE run has been resumed and recently peak luminosity of 1.0x1032 cm-2s-1 and integrated luminosity of 6.2 pb-1/day have been achieved. The scientific program of the three high-energy experiments sharing DAFNE operation will be completed approximately by the end of year 2006. A scientific program for DAFNE beyond that date has not been defined yet and it is matter of discussion in the high-energy physics and accelerator physics communities. In this paper we present some future scenarios for DAFNE, discussing the expected ultimate performances of the machine as it is now and addressing the design for an energy and/or luminosity upgrade. The options presented in the following are not exhaustive and they are intended to give a glance of what is doable using the existing infrastructures.

physics.acc-ph

DAFNE operation with the FINUDA experiment

DAFNE operation restarted in September 2003, after a six month shut-down for the installation of FINUDA, a magnetic detector dedicated to the study of hypernuclear physics. FINUDA is the third experiment running on DAFNE and operates while keeping on place the other detector KLOE. During the shut-down both Interaction Regions have been equipped with remotely controlled quadrupoles in order to operate at different solenoid fields. Among many other hardware upgrades one of the most significant is the reshaping of the wiggler pole profile to improve the field quality and the machine dynamic aperture. Commissioning of the collider in the new configuration has been completed in short time. The peak luminosity delivered to FINUDA has reached 6 10^31 s-1cm-2, with a daily integrated value close to 4 pb-1.

physics.acc-ph

Modeling skin effect in large magnetized iron detectors

The experimental problem of the calibration of magnetic field in large iron detectors is discussed. Emphasis is laid on techniques based on ballistic measurements as the ones employed by MINOS or OPERA.In particular, we provide analytical formulas to model the behavior of the apparatus in the transient regime, keeping into account eddy current effects and the finite penetration velocity of the driving fields. These formulas ease substantially the design of the calibration apparatus.Results are compared with experimental data coming from a prototype of the OPERA spectrometer.

hep-ex