SearcharxivSearch

arXiv subjects

M. Inuzuka

Publications and source records attributed to M. Inuzuka.

4 recordsLinked to original sources

Development of a Time Projection Chamber Using Gas Electron Multipliers (GEM-TPC)

We developed a prototype time projection chamber using gas electron multipliers (GEM-TPC) for high energy heavy ion collision experiments. To investigate its performance, we conducted a beam test with 3 kinds of gases (Ar(90%)-CH4(10%), Ar(70%)-C2H6(30%) and CF4). Detection efficiency of 99%, and spatial resolution of 79 $μ$m in the pad-row direction and 313 $μ$m in the drift direction were achieved. The test results show that the GEM-TPC meets the requirements for high energy heavy ion collision experiments. The configuration and performance of the GEM-TPC are described.

physics.ins-det

A Hadron Blind Detector for the PHENIX Experiment at RHIC

A Hadron Blind Detector (HBD) is being developed for the PHENIX experiment at RHIC. It consists of a Cherenkov radiator operated with pure CF4 directly coupled in a windowless configuration to a triple-GEM detector element with a CsI photocathode and pad readout. The HBD operates in the bandwidth 6-11.5 eV(110-200 nm). We studied the detector response to minimum ionizing particles and to electrons. We present measurements of the CsI quantum efficiency, which are in very good agreement with previously published results over the bandwidth 6-8.3 eV and extend them up to 10.3 eV. Discharge probability andaging studies of the GEMs and the CsI photocathode in pure CF4 are presented.

physics.ins-det

Development of a triple GEM UV-photon detector operated in pure CF4 for the PHENIX experiment

Results obtained with a triple GEM detector operated in pure CF4 with and without a reflective CsI photocathode are presented. The detector operates in a stable mode at gains up to 10^4. A deviation from exponential growth starts to develop when the total charge exceeds ~ 4 10^6 e leading to gain saturation when the total charge is ~ 2 10^7 e and making the structure relatively robust against discharges. No aging effects are observed in the GEM foils after a total accumulated charge of ~ 10 mC/cm^2 at the anode. The ion back-flow current to the reflective photocathode is comparable to the electron current to the anode. However, no significant degradation of the CsI photocathode is observed for a total ion back-flow charge of ~ 7 mC/cm^2.

physics.ins-det

The ZEUS Forward Plug Calorimeter with Lead-Scintillator Plates and WLS Fiber Readout

A Forward Plug Calorimeter (FPC) for the ZEUS detector at HERA has been built as a shashlik lead-scintillator calorimeter with wave length shifter fiber readout. Before installation it was tested and calibrated using the X5 test beam facility of the SPS accelerator at CERN. Electron, muon and pion beams in the momentum range of 10 to 100 GeV/c were used. Results of these measurements are presented as well as a calibration monitoring system based on a $^{60}$Co source.

hep-ex