Searcharxiv⌕ Search

arXiv subjects

M. J. V. Streeter

Publications and source records attributed to M. J. V. Streeter.

At least 19 recordsLinked to original sources

Experimental demonstration of Flying-Focus enhanced Thomson scattering

We report the experimental demonstration of a spatiotemporally engineered "Flying-Focus" laser pulse for enhanced x-ray generation in relativistic Thomson scattering. A combination of longitudinal chromatic aberration, angular dispersion, and group delay dispersion was applied to an ultrashort relativistically intense laser pulse to control the motion of its focal point. Precise tuning of the group delay dispersion was used to match the velocity of the focus to the trajectory of a counterpropagating electron bunch, produced by a laser wakefield accelerator. This prolonged the Thomson scattering interaction while reducing nonlinear effects, leading to an enhanced x-ray yield. The approach has the potential to increase the spectral density and brightness of the x-ray beam by orders of magnitude compared to equivalent focusing without spatiotemporal control. This experiment establishes a new technique for structured-light control at high intensity, demonstrating the realization of dynamic intensity structures that enhance light-matter interactions and for the generation of ultra-bright radiation sources.

physics.optics↗

High brightness multi-MeV photon source driven by a petawatt-scale laser wakefield accelerator

We present an experimental demonstration of a bright multi-MeV gamma source driven by a petawatt laser. The source generates on average $(1.2\pm0.6)\times10^9$ photons above 1 MeV per pulse, exceeding those of previous all-optical sources by a hundred times, and reached a peak spectral brightness of $(3.9 \pm 1.5)\times 10^{22}$ photons/mm$^2$/mrad$^2$/s/0.1%BW at $ε_γ\approx11$ MeV. The source was produced by inverse Compton scattering of a laser wakefield accelerated GeV electron beam and its back-reflected driving laser pulse. Its performance is well described by a simple model of the laser and electron properties at the collision point that allows quantitative predictions and identifies clear strategies to further enhance radiation efficiency. Our results highlight the promise of this source for fundamental physics studies, as well as for applications of nuclear resonance fluorescence and nuclear transmutation.

physics.plasm-ph↗

Characterization and automated optimization of laser-driven proton beams from converging liquid sheet jet targets

Compact, stable, and versatile laser-driven ion sources hold great promise for applications ranging from medicine to materials science and fundamental physics. While single-shot sources have demonstrated favorable beam properties, including the peak fluxes necessary for several applications, high repetition rate operation will be necessary to generate and sustain the high average flux needed for many of the most exciting applications of laser-driven ion sources. Further, to navigate through the high-dimensional space of laser and target parameters towards experimental optima, it is essential to develop ion acceleration platforms compatible with machine learning learning techniques and capable of autonomous real-time optimization. Here we present a multi-Hz ion acceleration platform employing a liquid sheet jet target. We characterize the laser-plasma interaction and the laser-driven proton beam across a variety of key parameters governing the interaction using an extensive suite of online diagnostics. We also demonstrate real-time, closed-loop optimization of the ion beam maximum energy by tuning the laser wavefront using a Bayesian optimization scheme. This approach increased the maximum proton energy by 11% compared to a manually-optimized wavefront by enhancing the energy concentration within the laser focal spot, demonstrating the potential for closed-loop optimization schemes to tune future ion accelerators for robust high repetition rate operation.

physics.plasm-ph↗

Bounding elastic photon-photon scattering at $\sqrt s \approx 1\,$MeV using a laser-plasma platform

We report on a direct search for elastic photon-photon scattering using x-ray and $γ$ photons from a laser-plasma based experiment. A gamma photon beam produced by a laser wakefield accelerator provided a broadband gamma spectrum extending to above $E_γ= 200$ MeV. These were collided with a dense x-ray field produced by the emission from a laser heated germanium foil at $E_x \approx 1.4$ keV, corresponding to an invariant mass of $\sqrt{s} = 1.22 \pm 0.22$ MeV. In these asymmetric collisions elastic scattering removes one x-ray and one high-energy $γ$ photon and outputs two lower energy $γ$ photons. No changes in the $γ$ photon spectrum were observed as a result of the collisions allowing us to place a 95% upper bound on the cross section of $1.5 \times 10^{15}\,μ$b. Although far from the QED prediction, this represents the lowest upper limit obtained so far for $\sqrt{s} \lesssim 1$ MeV.

hep-ex↗

Single-pulse Gy-scale irradiation of biological cells at $10^{13}$ Gy/s average dose-rates from a laser-wakefield accelerator

We report on the first experimental characterization of a laser-wakefield accelerator able to deliver, in a single pulse, doses in excess of \unit[1]{Gy} on timescales of the order of a hundred femtoseconds, reaching unprecedented average dose-rates up to \unit[10$^{13}$]{Gy/s}. The irradiator is demonstrated to deliver doses tuneable up to \unit[2.2]{Gy} in a cm$^2$ area and with a high degree of longitudinal and transverse uniformity in a single irradiation. In this regime, proof-of-principle irradiation of patient-derived glioblastoma stem-like cells and human skin fibroblast cells show indications of a differential cellular response, when compared to reference irradiations at conventional dose-rates. These include a statistically significant increase in relative biological effectiveness ($1.40\pm0.08$ at 50\% survival for both cell lines) and a significant reduction of the relative radioresistance of tumour cells. Data analysis provides preliminary indications that these effects might not be fully explained by induced oxygen depletion in the cells but may be instead linked to a higher complexity of the damages triggered by the ultra-high density of ionising tracks of femtosecond-scale radiation pulses. These results demonstrate an integrated platform for systematic radiobiological studies at unprecedented beam durations and dose-rates, a unique infrastructure for translational research in radiobiology at the femtosecond scale.

physics.med-ph↗

Extended X-ray absorption spectroscopy using an ultrashort pulse laboratory-scale laser-plasma accelerator

Laser-driven compact particle accelerators can provide ultrashort pulses of broadband X-rays, well suited for undertaking X-ray absorption spectroscopy measurements on a femtosecond timescale. Here the Extended X-ray Absorption Fine Structure (EXAFS) features of the K-edge of a copper sample have been observed over a 250 eV window in a single shot using a laser wakefield accelerator, providing information on both the electronic and ionic structure simultaneously. This unique capability will allow the investigation of ultrafast processes, and in particular, probing high-energy-density matter and physics far-from-equilibrium where the sample refresh rate is slow and shot number is limited. For example, states that replicate the tremendous pressures and temperatures of planetary bodies or the conditions inside nuclear fusion reactions. Using high-power lasers to pump these samples also has the advantage of being inherently synchronised to the laser-driven X-ray probe. A perspective on the additional strengths of a laboratory-based ultrafast X-ray absorption source is presented.

physics.plasm-ph↗

A Bayesian Framework to Investigate Radiation Reaction in Strong Fields

Recent experiments aiming to measure phenomena predicted by strong field quantum electrodynamics have done so by colliding relativistic electron beams and high-power lasers. In such experiments, measurements of the collision parameters are not always feasible, however, precise knowledge of these parameters is required for accurate tests of strong-field quantum electrodynamics. Here, we present a novel Bayesian inference procedure which infers collision parameters that could not be measured on-shot. This procedure is applicable to all-optical non-linear Compton scattering experiments investigating radiation reaction. The framework allows multiple diagnostics to be combined self-consistently and facilitates the inclusion of prior or known information pertaining to the collision parameters. Using this Bayesian analysis, the relative validity of the classical, quantum-continuous and quantum-stochastic models of radiation reaction were compared for a series of test cases, which demonstrate the accuracy and model selection capability of the framework and and highlight its robustness in the event that the experimental values of fixed parameters differ from their values in the models.

physics.data-an↗

A New Optimization Methodology for Polar Direct Drive Illuminations at the National Ignition Facility

A new, efficient, algorithmic approach to create illumination configurations for laser driven high energy density physics experiments is proposed. The method is applied to a polar direct drive solid target experiment at the National Ignition Facility (NIF), where it is simulated to create more than x2 higher peak pressure and x1.4 higher density by maintaining better shock uniformity. The analysis is focused on projecting shocks into solid targets at the NIF, but with minor adaptations the method could be applied to implosions, other target geometries and other facilities.

physics.plasm-ph↗

Laser-driven electron source suitable for single-shot Gy-scale irradiation of biological cells at dose-rates exceeding $10^{10}$ Gy/s

We report on the first systematic characterisation of a tuneable laser-driven electron source capable of delivering Gy-scale doses in a duration of 10 - 20 ps, thus reaching unprecedented dose rates in the range of $10^{10} - 10^{12}$ Gy/s. Detailed characterisation of the source indicates, in agreement with Monte-Carlo simulations, single-shot delivery of multi-Gy doses per pulse over cm-scale areas, with a high degree of spatial uniformity. The results reported here confirm that a laser-driven source of this kind can be used for systematic studies of the response of biological cells to picosecond-scale radiation at ultra-high dose rates.

physics.med-ph↗

Experimental characterisation of a single-shot spectrometer for high-flux, GeV-scale gamma-ray beams

We report on the first experimental characterisation of a gamma-ray spectrometer designed to spectrally resolve high-flux photon beams with energies in the GeV range. The spectrometer has been experimentally characterised using a bremsstrahlung source obtained at the Apollon laser facility during the interaction of laser-wakefield accelerated electron beams (maximum energy of 1.7 GeV and overall charge of 207$\pm$62 pC) with a 1 mm thick tantalum target. Experimental data confirms the possibility of performing single-shot measurements, without the need for accumulation, with a high signal to noise ratio. Scaling the results to photons in the multi-GeV range suggests the possibility of achieving percent-level energy resolution, as required, for instance, by the next generation of experiments in strong-field quantum electrodynamics.

physics.ins-det↗

Narrow bandwidth, low-emittance positron beams from a laser-wakefield accelerator

The rapid progress that plasma wakefield accelerators are experiencing is now posing the question as to whether they could be included in the design of the next generation of high-energy electron-positron colliders. However, the typical structure of the accelerating wakefields presents challenging complications for positron acceleration. Research in plasma-based acceleration of positrons has thus far experienced limited experimental progress due to the lack of positron beams suitable to seed a plasma accelerator. Here, we report on the first experimental demonstration of a laser-driven source of ultra-relativistic positrons with sufficient spectral and spatial quality to be injected in a plasma accelerator. Our results indicate, in agreement with numerical simulations, selection and transport of positron beamlets containing $N_{e+}\geq10^5$ positrons in a 5\% bandwidth around 600 MeV, with femtosecond-scale duration and micron-scale normalised emittance. Particle-in-cell simulations show that positron beams of this kind can be efficiently guided and accelerated in a laser-driven plasma accelerator, with favourable scalings to further increase overall charge and energy using PW-scale lasers. The results presented here demonstrate the possibility of performing experimental studies of positron acceleration in a plasma wakefield.

physics.acc-ph↗

Automated control and optimisation of laser driven ion acceleration

The interaction of relativistically intense lasers with opaque targets represents a highly non-linear, multi-dimensional parameter space. This limits the utility of sequential 1D scanning of experimental parameters for the optimisation of secondary radiation, although to-date this has been the accepted methodology due to low data acquisition rates. High repetition-rate (HRR) lasers augmented by machine learning present a valuable opportunity for efficient source optimisation. Here, an automated, HRR-compatible system produced high fidelity parameter scans, revealing the influence of laser intensity on target pre-heating and proton generation. A closed-loop Bayesian optimisation of maximum proton energy, through control of the laser wavefront and target position, produced proton beams with equivalent maximum energy to manually-optimized laser pulses but using only 60% of the laser energy. This demonstration of automated optimisation of laser-driven proton beams is a crucial step towards deeper physical insight and the construction of future radiation sources.

physics.plasm-ph↗

Characterisation of Laser Wakefield Acceleration Efficiency with Octave Spanning Near-IR Spectrum Measurements

We report on experimental measurements of energy transfer efficiencies in a GeV-class laser wakefield accelerator. Both the transfer of energy from the laser to the plasma wakefield, and from the plasma to the accelerated electron beam were diagnosed by simultaneous measurement of the deceleration of laser photons and the acceleration of electrons as a function of plasma length. The extraction efficiency, which we define as the ratio of the energy gained by the electron beam to the energy lost by the self-guided laser mode, was maximised at $19\pm3$\% by tuning of the plasma density and length. The additional information provided by the octave-spanning laser spectrum measurement allows for independent optimisation of the plasma efficiency terms, which is required for the key goal of improving the overall efficiency of laser wakefield accelerators.

physics.plasm-ph↗

Mechanisms to control laser-plasma coupling in laser wakefield electron acceleration

Experimental results, supported by precise modelling, demonstrate optimisation of a plasma-based injector with intermediate laser pulse energy ($<1$ J), corresponding to a normalised vector potential $a_0 = 2.15$, using ionisation injection in a tailored plasma density profile. An increase in electron bunch quality and energy is achieved experimentally with the extension of the density downramp at the plasma exit. Optimisation of the focal position of the laser pulse in the tailored plasma density profile is shown to efficiently reduce electron bunch angular deviation, leading to a better alignment of the electron bunch with the laser axis. Single peak electron spectra are produced in a previously unexplored regime by combining an early focal position and adaptive optic control of the laser wavefront through optimising the symmetry of the pre-focal laser energy distribution. Experimental results have been validated through particle-in-cell simulations using realistic laser energy, phase distribution, and temporal envelope, allowing for accurate predictions of difficult to model parameters, such as total charge and spatial properties of the electron bunches, opening the way for more accurate modelling for the design of plasma-based accelerators.

physics.plasm-ph↗

A laser-plasma platform for photon-photon physics

We describe a laser-plasma platform for photon-photon collision experiments to measure fundamental quantum electrodynamic processes such as the linear Breit-Wheeler process with real photons. The platform has been developed using the Gemini laser facility at the Rutherford Appleton Laboratory. A laser wakefield accelerator and a bremsstrahlung convertor are used to generate a collimated beam of photons with energies of hundreds of MeV, that collide with keV x-ray photons generated by a laser heated plasma target. To detect the pairs generated by the photon-photon collisions, a magnetic transport system has been developed which directs the pairs onto scintillation-based and hybrid silicon pixel single particle detectors. We present commissioning results from an experimental campaign using this laser-plasma platform for photon-photon physics, demonstrating successful generation of both photon sources, characterisation of the magnetic transport system and calibration of the single particle detectors, and discuss the feasibility of this platform for the observation of the Breit-Wheeler process. The design of the platform will also serve as the basis for the investigation of strong-field quantum electrodynamic processes such as the nonlinear Breit-Wheeler and the Trident process, or eventually, photon-photon scattering.

physics.plasm-ph↗

Automation and control of laser wakefield accelerators using Bayesian optimisation

Laser wakefield accelerators promise to revolutionise many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimisation of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimised its outputs by simultaneously varying up to 6 parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimisation of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

physics.acc-ph↗

Compton recoil effects in staging of laser wakefield accelerators

Laser plasma accelerators capable of generating >10 GeV electron beams may require plasma mirrors to remove undepleted laser energy at the end of each accelerator stage. Near the plasma mirror surface, the electron bunch can interact with the reflected light, resulting in inverse Compton scattering. For realistic conditions, we show that a significant fraction of electrons emit one or more photons, increasing the energy spread of the electron bunch. We provide an analytical expression for calculating this effect, and use it to estimate the minimum drift space required before the plasma mirror to meet given energy spread specifications. Mitigation strategies, necessary to achieve sub-percent energy spread in multi-GeV laser wakefield electron sources, are proposed and explored.

physics.plasm-ph↗

Bright X-ray radiation from plasma bubbles in an evolving laser wakefield accelerator

We show that the properties of the electron beam and bright x-rays produced by a laser wakefield accelerator can be predicted if the distance over which the laser self-focuses and compresses prior to self-injection is taken into account. A model based on oscillations of the beam inside a plasma bubble shows that performance is optimised when the plasma length is matched to the laser depletion length. With a 200~TW laser pulse this results in an x-ray beam with median photon energy of \unit[20]{keV}, $> 6\times 10^{8}$ photons above \unit[1]{keV} per shot and a peak brightness of $\unit[3 \times 10^{22}]{photons~s^{-1}mrad^{-2}mm^{-2} (0.1\% BW)^{-1}}$.

physics.plasm-ph↗