SearcharxivSearch

arXiv subjects

M. Kitaguchi

Publications and source records attributed to M. Kitaguchi.

At least 37 records · Page 2Linked to original sources

Measurement of the transverse asymmetry of $γ$-rays in the $^{117}$Sn(n,$γ$)$^{118}$Sn reaction

Largely enhanced parity-violating effects observed in compound resonances induced by epithermal neutrons are currently attributed to the mixing of parity-unfavored partial amplitudes in the entrance channel of the compound states. Furthermore, it is proposed that the same mechanism that enhances the parity-violation also enhances the breaking of time-reversal-invariance in the compound nucleus. The entrance-channel mixing induces energy-dependent spin-angular correlations of individual $γ$-rays emitted from the compound nuclear state. For a detailed study of the mixing model, a $γ$-ray yield in the reaction of $^{117}$Sn(n,$γ$)$^{118}$Sn was measured using the pulsed beam of polarized epithermal neutrons and Ge detectors. An angular dependence of asymmetric $γ$-ray yields for the orientation of the neutron polarization was observed.

nucl-ex

Angular distribution of $γ$ rays from the p-wave resonance of $^{118}$Sn

The neutron energy-dependent angular distribution of $γ$ rays from $^{117}{\rm Sn}(n,γ)$ reaction was measured with germanium detectors and a pulsed neutron beam. The angular distribution was clearly observed in $γ$-ray emissions with an energy of 9327 keV which corresponds to the transition from a neutron resonance of $^{117}{\rm Sn}+n$ to the ground state of $^{118}{\rm Sn}$. The angular distribution causes an angular-dependent asymmetric resonance shape. An asymmetry $A_{\rm LH}$ was defined as $(N_{\rm L}-N_{\rm H})/(N_{\rm L}+N_{\rm H})$, where $N_{\rm L}$ and $N_{\rm H}$ are integrated values for lower- and higher-energy regions of a neutron resonance, respectively. We found that the $A_{\rm LH}$ has the angular dependence of $(A \cos θ_γ+B)$, where $θ_γ$ is the $γ$-ray emission angle with respect to the incident neutron momentum, with $A=0.394 \pm 0.073$ and $B = 0.118 \pm 0.029$ in the 1.33 eV p-wave resonance.

nucl-ex

Measurement of nuclear spin relaxation time in lanthanum aluminate for development of polarized lanthanum target

The nuclear spin-lattice relaxation time ($T_1$) of lanthanum and aluminum nuclei in a single crystal of lanthanum aluminate doped with neodymium ions is studied to estimate the feasibility of the dynamically polarized lanthanum target applicable to beam experiments. The application of our interest is the study of fundamental discrete symmetries in the spin optics of epithermal neutrons. This study requires a highly flexible choice of the applied magnetic field for neutron spin control and favors longer $T_1$ under lower magnetic field and at higher temperature. The $T_1$ of $^{139}{\rm La}$ and ${}^{27}{\rm Al}$ was measured under magnetic fields of $0.5$-$2.5$ T and at temperatures of $0.1$-$1.5$ K and found widely distributed up to 100 h. The result suggests that the $T_1$ can be as long as $T_1 \sim$ 1 h at $0.1$ K with a magnetic field of $0.1$ T, which partially fulfills the requirement of the neutron beam experiment. Possible improvements to achieve a longer $T_1$ are discussed.

physics.ins-det

Precise Neutron Lifetime Measurement Using Pulsed Neutron Beams at J-PARC

A neutron decays into a proton, an electron, and an anti-neutrino through the beta-decay process. The decay lifetime ($\sim$880 s) is an important parameter in the weak interaction. For example, the neutron lifetime is a parameter used to determine the |$V_{\rm ud}$| parameter of the CKM quark mixing matrix. The lifetime is also one of the input parameters for the Big Bang Nucleosynthesis, which predicts light element synthesis in the early universe. However, experimental measurements of the neutron lifetime today are significantly different (8.4 s or 4.0$σ$) depending on the methods. One is a bottle method measuring surviving neutron in the neutron storage bottle. The other is a beam method measuring neutron beam flux and neutron decay rate in the detector. There is a discussion that the discrepancy comes from unconsidered systematic error or undetectable decay mode, such as dark decay. A new type of beam experiment is performed at the BL05 MLF J-PARC. This experiment measured neutron flux and decay rate simultaneously with a time projection chamber using a pulsed neutron beam. We will present the world situation of neutron lifetime and the latest results at J-PARC.

hep-ex

Energy dependent angular distribution of individual $γ$-rays in the $^{139}$La($n$, $γ$)$^{140}$La* reaction

Neutron energy-dependent angular distributions were observed for individual $γ$-rays from the 0.74 eV p-wave resonance of $^{139}$La+$n$ to several lower excited states of $^{140}$La. The $γ$-ray signals were analyzed in a two dimensional histogram of the $γ$-ray energy, measured with distributed germanium detectors, and neutron energy, determined with the time-of-flight of pulsed neutrons, to identify the neutron energy dependence of the angular distribution for each individual $γ$-rays. The angular distribution was also found for a photopeak accompanied with a faint p-wave resonance component in the neutron energy spectrum. Our results can be interpreted as interference between s- and p-wave amplitudes which may be used to study discrete symmetries of fundamental interactions.

nucl-ex

Neutron lifetime measurement with pulsed cold neutrons

The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.

hep-ex

Measurement of $γ$ rays from $^6$LiF tile as an inner wall of a neutron-decay detector

A neutron lifetime measurement conducted at the Japan Proton Accelerator Research Complex (J-PARC) is counting the number of electrons from neutron decays with a time projection chamber (TPC). The $γ$ rays produced in the TPC cause irreducible background events. To achieve the precise measurement, the inner walls of the TPC consist of $^6$Li-enriched lithium-fluoride ($^6$LiF) tiles to suppress the amount of $γ$ rays. In order to estimate the amount of $γ$ rays from the $^{6}{\rm LiF}$ tile, prompt gamma ray analysis (PGA) measurements were performed using germanium detectors. We reconstructed the measured $γ$-ray energy spectrum using a Monte Carlo simulation with the stripping method. Comparing the measured spectrum with a simulated one, the number of $γ$ rays emitted from the$^{6}{\rm LiF}$ tile was $(2.3^{+0.7}_{-0.3}) \times 10^{-4}$ per incident neutron. This is $1.4^{+0.5}_{-0.2}$ times the value assumed for a mole fraction of the $^{6}{\rm LiF}$ tile. We concluded that the amount of $γ$ rays produced from the $^{6}{\rm LiF}$ tile is not more twice the originally assumed value.

physics.ins-det

New high-sensitivity searches for neutrons converting into antineutrons and/or sterile neutrons at the European Spallation Source

The violation of Baryon Number, $\mathcal{B}$, is an essential ingredient for the preferential creation of matter over antimatter needed to account for the observed baryon asymmetry in the universe. However, such a process has yet to be experimentally observed. The HIBEAM/NNBAR %experiment program is a proposed two-stage experiment at the European Spallation Source (ESS) to search for baryon number violation. The program will include high-sensitivity searches for processes that violate baryon number by one or two units: free neutron-antineutron oscillation ($n\rightarrow \bar{n}$) via mixing, neutron-antineutron oscillation via regeneration from a sterile neutron state ($n\rightarrow [n',\bar{n}'] \rightarrow \bar{n}$), and neutron disappearance ($n\rightarrow n'$); the effective $Δ\mathcal{B}=0$ process of neutron regeneration ($n\rightarrow [n',\bar{n}'] \rightarrow n$) is also possible. The program can be used to discover and characterise mixing in the neutron, antineutron, and sterile neutron sectors. The experiment addresses topical open questions such as the origins of baryogenesis, the nature of dark matter, and is sensitive to scales of new physics substantially in excess of those available at colliders. A goal of the program is to open a discovery window to neutron conversion probabilities (sensitivities) by up to three orders of magnitude compared with previous searches. The opportunity to make such a leap in sensitivity tests should not be squandered. The experiment pulls together a diverse international team of physicists from the particle (collider and low energy) and nuclear physics communities, while also including specialists in neutronics and magnetics.

physics.ins-det

Development and application of a $^3$He Neutron Spin Filter at J-PARC

We are developing a neutron polarizer with polarized $^3$He gas, referred to as a $^3$He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A $^3$He gas-filling station was constructed at J-PARC, and several $^3$He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing $^3$He cells, and compact pumping systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A $^3$He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110~W laser. Recently, the first user experiment utilizing the $^3$He spin filter was conducted, and there have been several more since then. The development and utilization of $^3$He spin filters at MLF of J-PARC are reported.

physics.ins-det

Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement

In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement. In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.

nucl-ex

First ultracold neutrons produced at TRIUMF

We installed a source for ultracold neutrons at a new, dedicated spallation target at TRIUMF. The source was originally developed in Japan and uses a superfluid-helium converter cooled to 0.9$\,$K. During an extensive test campaign in November 2017, we extracted up to 325000 ultracold neutrons after a one-minute irradiation of the target, over three times more than previously achieved with this source. The corresponding ultracold-neutron density in the whole production and guide volume is 5.3$\,$cm$^{-3}$. The storage lifetime of ultracold neutrons in the source was initially 37$\,$s and dropped to 24$\,$s during the eighteen days of operation. During continuous irradiation of the spallation target, we were able to detect a sustained ultracold-neutron rate of up to 1500$\,$s$^{-1}$. Simulations of UCN production, UCN transport, temperature-dependent UCN yield, and temperature-dependent storage lifetime show excellent agreement with the experimental data and confirm that the ultracold-neutron-upscattering rate in superfluid helium is proportional to $T^7$.

physics.ins-det

A Cold/Ultracold Neutron Detector using Fine-grained Nuclear Emulsion with Spatial Resolution less than 100 nm

A new type of cold/ultracold neutron detector that can realize a spatial resolution of less than 100 nm was developed using nuclear emulsion. The detector consists of a fine-grained nuclear emulsion coating and a 50-nm thick $^{10}$B$_4$C layer for the neutron conversion. The detector was exposed to cold and ultracold neutrons (UCNs) at the J-PARC. Detection efficiencies were measured as (0.16$\pm$0.02)% and (12$\pm$2)% for cold and ultracold neutrons consistently with the $^{10}$B content in the converter. Positions of individual neutrons can be determined by observing secondary particle tracks recorded in the nuclear emulsion. The spatial resolution of incident neutrons were found to be in the range of 11-99 nm in the angle region of tan$θ\leq 1.9$, where $θ$ is the angle between a recorded track and the normal direction of the converter layer. The achieved spatial resolution corresponds to the improvement of one or two orders of magnitude compared with conventional techniques and it is comparable with the wavelength of UCNs.

physics.ins-det

Pulsed UCN production using a Doppler shifter at J-PARC

We have constructed a Doppler-shifter-type pulsed ultra-cold neutron (UCN) source at the Materials and Life Science Experiment Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC). Very-cold neutrons (VCNs) with 136-$\mathrm{m/s}$ velocity in a neutron beam supplied by a pulsed neutron source are decelerated by reflection on a m=10 wide-band multilayer mirror, yielding pulsed UCN. The mirror is fixed to the tip of a 2,000-rpm rotating arm moving with 68-$\mathrm{m/s}$ velocity in the same direction as the VCN. The repetition frequency of the pulsed UCN is $8.33~\mathrm{Hz}$ and the time width of the pulse at production is $4.4~\mathrm{ms}$. In order to increase the UCN flux, a supermirror guide, wide-band monochromatic mirrors, focus guides, and a UCN extraction guide have been newly installed or improved. The $1~\mathrm{MW}$-equivalent count rate of the output neutrons with longitudinal wavelengths longer than $58~\mathrm{nm}$ is $1.6 \times 10^{2}~\mathrm{cps}$, while that of the true UCNs is $80~\mathrm{cps}$. The spatial density at production is $1.4~\mathrm{UCN/cm^{3}}$. This new UCN source enables us to research and develop apparatuses necessary for the investigation of the neutron electric dipole moment (nEDM).

physics.ins-det

Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams

A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.

physics.ins-det

Observation of the Spatial Distribution of Gravitationally Bound Quantum States of Ultracold Neutrons and Its Derivation Using the Wigner Function

Ultracold neutrons (UCNs) can be bound by the potential of terrestrial gravity and a reflecting mirror. The wave function of the bound state has characteristic modulations. We carried out an experiment to observe the vertical distribution of the UCNs above such a mirror at Institut Laue-Langevin in 2011. The observed modulation is in good agreement with that prediction by quantum mechanics using the Wigner function. The spatial resolution of the detector system is estimated to be 0.7 micro meter. This is the first observation of gravitationally bound states of UCNs with submicron spatial resolution.

hep-ex