SearcharxivSearch

arXiv subjects

M. Koch

Publications and source records attributed to M. Koch.

10 recordsLinked to original sources

The MuFusE Large-Volume Diamond Anvil Cell for Exploring Muon-Catalyzed Fusion at Higher Pressures and Temperatures

A new large-volume diamond anvil cell (DAC) has been developed for the Muon-catalyzed Fusion ($\mu$CF) Experiment (MuFusE), enabling the compression and heating of deuterium-tritium (d-t) mixtures to pressures and temperatures needed to advance $\mu$CF research. The MuFusE DAC achieves the large sample volumes necessary for high-precision fusion measurements while integrating cryogenic loading, all-metal sealing, and flexible bellows to maintain a secure environment during cell compression. Combined with remote pneumatic actuation and secondary containment, the DAC safely managed a 25 Ci tritium inventory while providing a clear optical path for in situ measurements of sample pressure and composition via laser spectroscopy. Utilizing 5 mm diameter diamond anvils oriented in the path of a high-intensity muon beam, the apparatus achieved a stable sample volume of 19.2 mm$^3$ at liquid density, pressures up to 933 MPa and temperatures up to 400 K - benchmarks that significantly exceed previously reported limits for static d-t targets.

physics.ins-det

Comment on "Interplay of Structural and Optoelectronic Properties in Formamidinium Mixed Tin-Lead Triiodide Perovskites"

Studying optoelectronic properties in FAPb$_{1-x}$Sn$_x$I$_3$ perovskites as a function of the lead:tin content, Parrott et al. observed the broadest luminescence linewidth and the largest luminescence Stokes shift in mixed compositions with Sn $ < 25$% and with $> 0.85$%. Since the largest effects of alloy disorder were expected for the 50:50 composition, it was concluded that the revealed disorder effects might arise from extrinsic factors that can be eliminated upon further crystal growth optimization. This comment shows that the largest effects of alloy disorder for perfectly random fluctuations in FAPb$_{1-x}$Sn$_x$I$_3$ perovskite are, in fact, expected for $x < 0.25$ and for $x > 0.85$. Therefore, further crystal growth optimization is futile.

cond-mat.mtrl-sci

On the Influence of Delay Line Uncertainty in THz Time-Domain Spectroscopy

Terahertz time-domain spectroscopy (THz TDS) is a well-known tool for material analysis in the terahertz frequency band. One crucial system component in every time-domain spectrometer is the delay line which is necessary to accomplish the sampling of the electric field over time. Despite the fact that most of the uncertainty sources in TDS have been discussed, the delay line uncertainty has not been considered in detail. We model the impact of delay line uncertainty on the acquired THz TDS data. Interferometric measurements of the delay line precision and THz time-domain data are used to validate the theoretical model.

physics.optics

Single-shot single-gate RF spin readout in silicon

For solid-state spin qubits, single-gate RF readout can help minimise the number of gates required for scale-up to many qubits since the readout sensor can integrate into the existing gates required to manipulate the qubits (Veldhorst 2017, Pakkiam 2018). However, a key requirement for a scalable quantum computer is that we must be capable of resolving the qubit state within single-shot, that is, a single measurement (DiVincenzo 2000). Here we demonstrate single-gate, single-shot readout of a singlet-triplet spin state in silicon, with an average readout fidelity of $82.9\%$ at a $3.3~\text{kHz}$ measurement bandwidth. We use this technique to measure a triplet $T_-$ to singlet $S_0$ relaxation time of $0.62~\text{ms}$ in precision donor quantum dots in silicon. We also show that the use of RF readout does not impact the maximum readout time at zero detuning limited by the $S_0$ to $T_-$ decay, which remained at approximately $2~\text{ms}$. This establishes single-gate sensing as a viable readout method for spin qubits.

cond-mat.mes-hall

Microcavity-enhanced Kerr nonlinearity in a vertical-external-cavity surface-emitting laser

Self-mode-locking has become an emerging path to the generation of ultrashort pulses with vertical-external-cavity surface-emitting lasers. In our work, a strong Kerr nonlinearity that is so far assumed to give rise to mode-locked operation is evidenced and a strong nonlinearity enhancement by the microcavity is revealed. We present wavelength-dependent measurements of the nonlinear absorption and nonlinear-refractive-index change in a gain chip using the Z-scan technique. We report negative nonlinear refraction up to 1.5E-11 cm2/W in magnitude in the (InGa)As/Ga(AsP) material system close to the laser design wavelength, which can lead to Kerr lensing. We show that by changing the angle of incidence of the probe beam with respect to the gain chip, the Kerr nonlinearity can be wavelength-tuned, shifting with the microcavity resonance. Such findings may ultimately lead to novel concepts with regard to tailored self-mode-locking behavior achievable by peculiar Kerr-lens chip designs for cost-effective, robust and compact fs-pulsed semiconductor lasers.

physics.optics

Analysis of femtosecond pump-probe photoelectron-photoion coincidence measurements applying Bayesian probability theory

Ultrafast dynamical processes in photoexcited molecules can be observed with pump-probe measurements, in which information about the dynamics is obtained from the transient signal associated with the excited state. Background signals provoked by pump and/or probe pulses alone often obscure these excited state signals. Simple subtraction of pump-only and/or probe-only measurements from the pump-probe measurement, as commonly applied, results in a degradation of the signal-to-noise ratio and, in the case of coincidence detection, the danger of overrated background subtraction. Coincidence measurements additionally suffer from false coincidences. Here we present a probabilistic approach based on Bayesian probability theory that overcomes these problems. For a pump-probe experiment with photoelectron-photoion coincidence detection we reconstruct the interesting excited-state spectrum from pump-probe and pump-only measurements. This approach allows to treat background and false coincidences consistently and on the same footing. We demonstrate that the Bayesian formalism has the following advantages over simple signal subtraction: (i) the signal-to-noise ratio is significantly increased, (ii) the pump-only contribution is not overestimated, (iii) false coincidences are excluded, (iv) prior knowledge, such as positivity, is consistently incorporated, (v) confidence intervals are provided for the reconstructed spectrum, and (vi) it is applicable to any experimental situation and noise statistics. Most importantly, by accounting for false coincidences, the Bayesian approach allows to run experiments at higher ionization rates, resulting in a significant reduction of data acquisition times. The application to pump-probe coincidence measurements on acetone molecules enables novel quantitative interpretations about the molecular decay dynamics and fragmentation behavior.

physics.atom-ph

DEPFET active pixel detectors for a future linear $e^+e^-$ collider

The DEPFET collaboration develops highly granular, ultra-transparent active pixel detectors for high-performance vertex reconstruction at future collider experiments. The characterization of detector prototypes has proven that the key principle, the integration of a first amplification stage in a detector-grade sensor material, can provide a comfortable signal to noise ratio of over 40 for a sensor thickness of 50-75 $\mathrm{\mathbf{μm}}$. ASICs have been designed and produced to operate a DEPFET pixel detector with the required read-out speed. A complete detector concept is being developed, including solutions for mechanical support, cooling and services. In this paper the status of DEPFET R & D project is reviewed in the light of the requirements of the vertex detector at a future linear $\mathbf{e^+ e^-}$ collider.

physics.ins-det

Observation of Coulomb-Assisted Dipole-Forbidden Intraexciton Transitions in Semiconductors

We use terahertz pulses to induce resonant transitions between the eigenstates of optically generated exciton populations in a high-quality semiconductor quantum-well sample. Monitoring the excitonic photoluminescence, we observe transient quenching of the $1s$ exciton emission, which we attribute to the terahertz-induced $1s$-to-$2p$ excitation. Simultaneously, a pronounced enhancement of the $2s$-exciton emission is observed, despite the $1s$-to-$2s$ transition being dipole forbidden. A microscopic many-body theory explains the experimental observations as a Coulomb-scattering mixing of the 2$s$ and 2$p$ states, yielding an effective terahertz transition between the 1$s$ and 2$s$ populations.

cond-mat.mes-hall

Two-photon gateway in one-atom cavity quantum electrodynamics

Single atoms absorb and emit light from a resonant laser beam photon by photon. We show that a single atom strongly coupled to an optical cavity can absorb and emit resonant photons in pairs. The effect is observed in a photon correlation experiment on the light transmitted through the cavity. We find that the atom-cavity system transforms a random stream of input photons into a correlated stream of output photons, thereby acting as a two-photon gateway. The phenomenon has its origin in the quantum anharmonicity of the energy structure of the atom-cavity system. Future applications could include the controlled interaction of two photons by means of one atom.

quant-ph

Status of a DEPFET pixel system for the ILC vertex detector

We have developed a prototype system for the ILC vertex detector based on DEPFET pixels. The system operates a 128x64 matrix (with ~35x25 square micron large pixels) and uses two dedicated microchips, the SWITCHER II chip for matrix steering and the CURO II chip for readout. The system development has been driven by the final ILC requirements which above all demand a detector thinned to 50 micron and a row wise read out with line rates of 20MHz and more. The targeted noise performance for the DEPFET technology is in the range of ENC=100 e-. The functionality of the system has been demonstrated using different radioactive sources in an energy range from 6 to 40keV. In recent test beam experiments using 6GeV electrons, a signal-to-noise ratio of S/N~120 has been achieved with present sensors being 450 micron thick. For improved DEPFET systems using 50 micron thin sensors in future, a signal-to-noise of 40 is expected.

physics.ins-det