SearcharxivSearch

arXiv subjects

M. Kuzniak

Publications and source records attributed to M. Kuzniak.

3 recordsLinked to original sources

Characterization of the ionization response of argon to nuclear recoils at the keV scale with the ReD experiment

In the recent years, argon-based experiments looking for Dark Matter in the Universe have explored the non-standard scenario in which Dark Matter is made by low-mass Weakly Interacting Massive Particles, of mass in the range of 1-10 GeV instead of the canonical hundreds of GeV. Detecting such particles is challenging, as their expected signatures are nuclear recoils with energies below 10 keV, observable solely via ionization. This necessitates a precise understanding of the detector response in this energy regime, which remains incomplete for argon. To address this, the ReD experiment was developed within the framework of the DarkSide-20k Collaboration to produce and characterize few-keV nuclear recoils. A compact dual-phase argon Time Projection Chamber (TPC) was irradiated with neutrons from a Cf252 source, to produce Ar recoils in the energy range of interest via (n,n') elastic scattering. A downstream spectrometer composed of 18 plastic scintillators detected the neutrons scattered off Ar nuclei, enabling recoil energy reconstruction via two-body kinematics. The ionization yield Qy of argon, defined as the number of electrons produced per unit energy deposit, was measured in a model-independent way between 2 and 10 keV. These measurements extend direct experimental coverage well below the previous limit of approximately 7 keV. The results are consistent with existing data above 7 keV, while they indicate a higher Qy at lower energies.

nucl-ex

Improving Photoelectron Counting and Particle Identification in Scintillation Detectors with Bayesian Techniques

Many current and future dark matter and neutrino detectors are designed to measure scintillation light with a large array of photomultiplier tubes (PMTs). The energy resolution and particle identification capabilities of these detectors depend in part on the ability to accurately identify individual photoelectrons in PMT waveforms despite large variability in pulse amplitudes and pulse pileup. We describe a Bayesian technique that can identify the times of individual photoelectrons in a sampled PMT waveform without deconvolution, even when pileup is present. To demonstrate the technique, we apply it to the general problem of particle identification in single-phase liquid argon dark matter detectors. Using the output of the Bayesian photoelectron counting algorithm described in this paper, we construct several test statistics for rejection of backgrounds for dark matter searches in argon. Compared to simpler methods based on either observed charge or peak finding, the photoelectron counting technique improves both energy resolution and particle identification of low energy events in calibration data from the DEAP-1 detector and simulation of the larger MiniCLEAN dark matter detector.

physics.ins-det

A direct experimental limit on neutron -- mirror neutron oscillations

In case a mirror world with a copy of our ordinary particle spectrum would exist, the neutron n and its degenerate partner, the mirror neutron ${\rm n'}$, could potentially mix and undergo ${\rm nn'}$ oscillations. The interaction of an ordinary magnetic field with the ordinary neutron would lift the degeneracy between the mirror partners, diminish the ${\rm n'}$-amplitude in the n-wavefunction and, thus, suppress its observability. We report an experimental comparison of ultracold neutron storage in a trap with and without superimposed magnetic field. No influence of the magnetic field is found and, assuming negligible mirror magnetic fields, a limit on the oscillation time $τ_{\rm nn'} > 103$ s (95% C.L.) is derived.

nucl-ex