SearcharxivSearch

arXiv subjects

M. L. Purschke

Publications and source records attributed to M. L. Purschke.

15 recordsLinked to original sources

Performance of an HRPPD in Tesla-scale magnetic fields

High-Rate Picosecond Photodetectors (HRPPDs) are state-of-the-art microchannel-plate (MCP) photodetectors that offer excellent timing and spatial resolution, together with high single-photon detection efficiency. They are currently being considered for the ePIC experiment at the future Electron Ion Collider (EIC) at Brookhaven National Laboratory. A key requirement for the application of this technology is reliable operation in a strong magnetic field up to 1.5 T, with magnetic flux lines at an inclination of $\le15^\circ$ to the normal of the MCP surface. Magnetic field-induced distortions of the collected charge in MCP-based detectors can be compensated by tuning the operating parameters; however, the objective of this study is to quantify this performance in the case of the EIC-HRPPD, a particular MCP stack-up specialized for operation within ePIC. This photosensor employs a high quantum efficiency photocathode, 10$~μ$m capillary pores, narrow transfer gaps, and a custom ceramic pixelated DC-coupled readout. This article explores the optimal operating parameters (mainly the voltages applied across the gaps and the MCPs) for single photon detection at various inclination angles in a uniform field up to 1.8 T. Ultimately, it was found that the gain and single photon detection efficiency of the HRRPD could be recovered over a range of polar inclination angles up to $\pm35^\circ$.

physics.ins-det

Intelligent experiments through real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and future EIC detectors

This R\&D project, initiated by the DOE Nuclear Physics AI-Machine Learning initiative in 2022, leverages AI to address data processing challenges in high-energy nuclear experiments (RHIC, LHC, and future EIC). Our focus is on developing a demonstrator for real-time processing of high-rate data streams from sPHENIX experiment tracking detectors. The limitations of a 15 kHz maximum trigger rate imposed by the calorimeters can be negated by intelligent use of streaming technology in the tracking system. The approach efficiently identifies low momentum rare heavy flavor events in high-rate p+p collisions (3MHz), using Graph Neural Network (GNN) and High Level Synthesis for Machine Learning (hls4ml). Success at sPHENIX promises immediate benefits, minimizing resources and accelerating the heavy-flavor measurements. The approach is transferable to other fields. For the EIC, we develop a DIS-electron tagger using Artificial Intelligence - Machine Learning (AI-ML) algorithms for real-time identification, showcasing the transformative potential of AI and FPGA technologies in high-energy nuclear and particle experiments real-time data processing pipelines.

physics.ins-det

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. This paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

physics.ins-det

A demonstrator for a real-time AI-FPGA-based triggering system for sPHENIX at RHIC

The RHIC interaction rate at sPHENIX will reach around 3 MHz in pp collisions and requires the detector readout to reject events by a factor of over 200 to fit the DAQ bandwidth of 15 kHz. Some critical measurements, such as heavy flavor production in pp collisions, often require the analysis of particles produced at low momentum. This prohibits adopting the traditional approach, where data rates are reduced through triggering on rare high momentum probes. We explore a new approach based on real-time AI technology, adopt an FPGA-based implementation using a custom designed FELIX-712 board with the Xilinx Kintex Ultrascale FPGA, and deploy the system in the detector readout electronics loop for real-time trigger decision.

physics.ins-det

Artificial Intelligence for the Electron Ion Collider (AI4EIC)

The Electron-Ion Collider (EIC), a state-of-the-art facility for studying the strong force, is expected to begin commissioning its first experiments in 2028. This is an opportune time for artificial intelligence (AI) to be included from the start at this facility and in all phases that lead up to the experiments. The second annual workshop organized by the AI4EIC working group, which recently took place, centered on exploring all current and prospective application areas of AI for the EIC. This workshop is not only beneficial for the EIC, but also provides valuable insights for the newly established ePIC collaboration at EIC. This paper summarizes the different activities and R&D projects covered across the sessions of the workshop and provides an overview of the goals, approaches and strategies regarding AI/ML in the EIC community, as well as cutting-edge techniques currently studied in other experiments.

physics.acc-ph

Design and Beam Test Results for the 2D Projective sPHENIX Electromagnetic Calorimeter Prototype

sPHENIX is a new experiment under construction for the Relativistic Heavy Ion Collider at Brookhaven National Laboratory which will study the quark-gluon plasma to further the understanding of QCD matter and interactions. A prototype of the sPHENIX electromagnetic calorimeter (EMCal) was tested at the Fermilab Test Beam Facility in Spring 2018 as experiment T-1044. The EMCal prototype corresponds to a solid angle of $ Δη\times Δϕ= 0.2 \times 0.2$ centered at pseudo-rapidity $η= 1$. The prototype consists of scintillating fibers embedded in a mix of tungsten powder and epoxy. The fibers project back approximately to the center of the sPHENIX detector, giving 2D projectivity. The energy response of the EMCal prototype was studied as a function of position and input energy. The energy resolution of the EMCal prototype was obtained after applying a position dependent energy correction and a beam profile correction. Two separate position dependent corrections were considered. The EMCal energy resolution was found to be $σ(E)/\langle E\rangle = 3.5(0.1) \oplus 13.3(0.2)/\sqrt{E}$ based on the hodoscope position dependent correction, and $σ(E)/\langle E\rangle = 3.0(0.1) \oplus 15.4(0.3)/\sqrt{E}$ based on the cluster position dependent correction. These energy resolution results meet the requirements of the sPHENIX physics program.

physics.ins-det

A Comparative Study of Straight-Strip and Zigzag-Interleaved Anode Patterns for MPGD Readouts

Due to their simplicity and versatility of design, straight strip or rectangular pad anode structures are frequently employed with micro-pattern gas detectors to reconstruct high precision space points for various tracking applications. The particle impact point is typically determined by interpolating the charge collected by several neighboring pads. However, to effectively extract the inherent positional information, the lateral spacing of the straight pads must be significantly smaller than the extent of the charge cloud. In contrast, highly interleaved anode patterns, such as zigzags, can adequately sample the charge with a pitch comparable to the size of the charge cloud or even larger. This has the considerable advantage of providing the same performance while requiring far fewer instrumented channels. Additionally, the geometric parameters defining such zigzag structures may be tuned to provide a uniform detector response without the need for so-called pad response functions, while simultaneously maintaining excellent position resolution. We have measured the position resolution of a variety of zigzag shaped anode patterns optimized for various MPGDs, including GEM, Micromegas, and micro-RWELL and compared this performance to the same detectors equipped with straight pads of varying pitch. We report on the performance results of each readout structure, evaluated under identical conditions in a test beam.

physics.ins-det

Results from a Prototype Combination TPC Cherenkov Detector with GEM Readout

A combination Time Projection Chamber-Cherenkov prototype detector has been developed as part of the Detector R&D Program for a future Electron Ion Collider. The prototype was tested at the Fermilab test beam facility to provide a proof of principle to demonstrate that the detector is able to measure particle tracks and provide particle identification information within a common detector volume. The TPC portion consists of a 10x10x10cm3 field cage, which delivers charge from tracks to a 10x10cm2 quadruple GEM readout. Tracks are reconstructed by interpolating the hit position of clusters on an array of 2x10mm2 zigzag pads The Cherenkov component consists of a 10x10cm2 readout plane segmented into 3x3 square pads, also coupled to a quadruple GEM. As tracks pass though the drift volume of the TPC, the generated Cherenkov light is able to escape through sparsely arranged wires making up one side of the field cage, facing the CsI photocathode of the Cherenkov detector. The Cherenkov detector is thus operated in a windowless, proximity focused configuration for high efficiency. Pure CF4 is used as the working gas for both detector components, mainly due to its transparency into the deep UV, as well as its high N0. Results from the beam test, as well as results on its particle id capabilities will be discussed.

physics.ins-det

Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the sPHENIX calorimeter system was tested at the Fermilab Test Beam Facility as experiment T-1044 in the spring of 2016. The electromagnetic calorimeter (EMCal) prototype is composed of scintillating fibers embedded in a mixture of tungsten powder and epoxy. The hadronic calorimeter (HCal) prototype is composed of tilted steel plates alternating with plastic scintillator. Results of the test beam reveal the energy resolution for electrons in the EMCal is $2.8\%\oplus~15.5\%/\sqrt{E}$ and the energy resolution for hadrons in the combined EMCal plus HCal system is $13.5\%\oplus 64.9\%/\sqrt{E}$. These results demonstrate that the performance of the proposed calorimeter system satisfies the sPHENIX specifications.

physics.ins-det

Design Studies for a TPC Readout Plane Using Zigzag Patterns with Multistage GEM Detectors

A new Time Projection Chamber (TPC) is currently under development for the sPHENIX experiment at RHIC. The TPC will be read out using multistage GEM detectors on each end and will be divided into approximately 40 pad layers in radius. Each pad layer is required to provide a spatial resolution of ~250 microns, which must be achieved with a minimal channel count in order to minimize the overall cost of the detector. The current proposal is to make the pads into a zigzag shape in order to enhance charge sharing among neighboring pads. This will allow for the possibility to interpolate the hit position to high precision, resulting in a position resolution many times better than the 2mm pitch of the readout pads. This paper discusses various simulation studies that were carried out to optimize the size and shape of the zigzag pads for the readout board for the TPC, along with the technical challenges in fabricating it. It also describes the performance of the first prototype readout board obtained from measurements carried out in the laboratory using a highly collimated X-ray source.

physics.ins-det

Performance of a Quintuple-GEM Based RICH Detector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high high laboratory momenta. For the upcoming Electron Ion Collider (EIC), the physics goals require hadron ($π$, K, p) identification up to $\sim$~50 GeV/c. In this region Cerenkov Ring-Imaging is the most viable solution.\newline The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for PID reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ($\frac{dN_γ}{dx} \propto \sin^2{\left(θ_C \right)}$) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas ($CF_4$). The detector concept is a natural extension of the PHENIX HBD detector achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

physics.ins-det

A Study of a Mini-drift GEM Tracking Detector

A GEM tracking detector with an extended drift region has been studied as part of an effort to develop new tracking detectors for future experiments at RHIC and for the Electron Ion Collider that is being planned for BNL or JLAB. The detector consists of a triple GEM stack with a small drift region that was operated in a mini TPC type configuration. Both the position and arrival time of the charge deposited in the drift region were measured on the readout plane which allowed the reconstruction of a short vector for the track traversing the chamber. The resulting position and angle information from the vector could then be used to improve the position resolution of the detector for larger angle tracks, which deteriorates rapidly with increasing angle for conventional GEM tracking detectors using only charge centroid information. Two types of readout planes were studied. One was a COMPASS style readout plane with 400 micron pitch XY strips and the other consisted of 2x10mm2 chevron pads. The detector was studied in test beams at Fermilab and CERN, along with additional measurements in the lab, in order to determine its position and angular resolution for incident track angles up to 45 degrees. Several algorithms were studied for reconstructing the vector using the position and timing information in order to optimize the position and angular resolution of the detector for the different readout planes. Applications for large angle tracking detectors at RHIC and EIC are also discussed.

physics.ins-det

The PHENIX Forward Silicon Vertex Detector

A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a rapidity range of $1.2<|η|<2.2$ that closely matches the two existing PHENIX muon arms. Each station consists of 48 individual silicon sensors, each of which contains two columns of mini-strips with 75 $μ$m pitch in the radial direction and lengths in the $ϕ$ direction varying from 3.4 mm at the inner radius to 11.5 mm at the outer radius. The FVTX has approximately 0.54 million strips in each endcap. These are read out with FPHX chips, developed in collaboration with Fermilab, which are wire bonded directly to the mini-strips. The maximum strip occupancy reached in central Au-Au collisions is approximately 2.8%. The precision tracking provided by this device makes the identification of muons from secondary vertices away from the primary event vertex possible. The expected distance of closest approach (DCA) resolution of 200 $μ$m or better for particles with a transverse momentum of 5 GeV/$c$ will allow identification of muons from relatively long-lived particles, such as $D$ and $B$ mesons, through their broader DCA distributions.

physics.ins-det

Single Transverse-Spin Asymmetry in Very Forward and Very Backward Neutral Particle Production for Polarized Proton Collisions at sqrt{s} = 200 GeV

In the 2001-2002 running period of the Relativistic Heavy Ion Collider (RHIC), transversely polarized protons were accelerated to 100 GeV for the first time, with collisions at sqrt{s} = 200 GeV. We present results from this run for single transverse spin asymmetries for inclusive production of neutral pions, photons and neutrons of the energy region 20 - 100 GeV for forward and backward production for angles between 0.3 mrad and 2.2 mrad with respect to the polarized proton direction. An asymmetry of A_N = (-0.090 +- 0.006 +- 0.009) x (1.0^{+0.47}_{-0.24}) was observed for forward neutron production, where the errors are statistical and systematic, and the scale error is from the beam polarization uncertainty. The forward photon and pi^0, and backward neutron, photon, and pi^0 asymmetries were consistent with zero. The large neutron asymmetry indicates a strong interference between a spin-flip amplitude, such as one pion exchange which dominates lower energy neutron production, and remaining spin non-flip amplitudes such as Reggeon exchange.

hep-ex

A Preshower Photon Multiplicity Detector for the WA98 Experiment

A high granularity preshower detector has been fabricated and installed in the WA98 Experiment at the CERN SPS for measuring the spatial distribution of photons produced in the forward region in lead ion induced interactions. Photons are counted by detecting the preshower signal in plastic scintillator pads placed behind a 3 radiation length thick lead converter and applying a threshold on the scintillator signal to reject the minimum ionizing particles. Techniques to improve the imaging of the fibre and performance of the detector in the high multiplicity environment of lead-lead collisions are described. Using Monte-Carlo simulation methods and test beam data of pi- and e- at various energies the photon counting efficiency is estimated to be 68% for central and 73% for peripheral Pb+Pb collisions.

hep-ex