SearcharxivSearch

arXiv subjects

M. Lestinsky

Publications and source records attributed to M. Lestinsky.

At least 19 recordsLinked to original sources

Rate coefficients for dielectronic recombination of N-like Ne

Dielectronic recombination (DR) for the process Ne$^{3+}$ + e$^{-}$ $\rightarrow$ Ne$^{2+}$ was investigated in a merged-beams arrangement at the heavy-ion storage ring CRYRING@ESR. The energy-dependent DR rate coefficient, $\alpha(E)$ was measured over the electron-ion collision energy range from 0 to 25 eV. The measurements cover the complete set of DR resonance series associated with $2s\to2p$ core excitations. The primary ion beam is estimated to have consisted of $44\%$ of the ions in the ground state, with the remainder distributed among long-lived metastable levels. In addition to the measurements we carried out quantum mechanical calculations of DR cross sections. The theoretical treatment includes contributions from the ground and excited metastable initial levels, weighted according to the estimated beam composition. From the experimental energy-resolved spectra, we derive a temperature dependent DR plasma recombination rate coefficient $\alpha_\mathrm{exp}(T)$ (PRRC). In the temperature domain where Ne$^{3+}$ is abundant in collisionally ionized plasmas, the present results show a good agreement with the present and with previous theoretical predictions. In the low-temperature regime characteristic for photoionized plasmas, the experimentally derived DR plasma rate coefficient is slightly larger than the published theoretical ones and does not agree within the experimental uncertainties. Parametrized fits of the experimentally derived DR PRRC are presented in order to facilitate an easy inclusion into astrophysical modelling codes.

physics.atom-ph

First Proton-Induced Cross Sections on a Stored Rare Ion Beam: Measurement of 118Te(p,{\gamma}) for Explosive Nucleosynthesis

We present the first nuclear cross-section measurements of (p,{\gamma}) and (p,n) reactions on 118Te at energies relevant for the {\gamma}-process nucleosynthesis. Absolute cross-section values for center-of-mass energies of 6, 7 and 10 MeV are provided, together with a theoretical extrapolation to the Gamow window. This experiment marks the first time that direct proton-induced reactions have been measured on a radioactive ion beam at the Experimental Storage Ring (ESR) at GSI, Darmstadt. This paves the way for a large variety of measurements, delivering new constraints for explosive nucleosynthesis and for physics beyond nuclear stability.

nucl-ex

Electron-ion collision spectroscopy at the CRYRING@ESR electron cooler

Electron-ion collision spectroscopy at heavy-ion storage rings aims at precision measurements of resonance features that occur in the cross sections of electron collision processes such as electron-impact ionization of ions or electron-ion recombination. As part of the international FAIR project, the low-energy ion storage ring CRYRING@ESR has been coupled with the heavy-ion accelerators operated by the GSI Helmholtz Center for Heavy-Ion Research in Darmstadt, Germany. This has created a new opportunity for stringent tests of strong field quantum electrodynamics by electron-ion collision spectroscopy of heavy few-electron ions. The present contribution provides details of the electron-ion collision spectroscopy setup at CRYRING@ESR and of the associated data-analysis procedures along with first results for nonresonant and resonant recombination of berylliumlike lead ions. For nonresonant recombination a recombination rate enhancement factor of 3.5 is found at zero electron-ion collision energy. For resonant recombination there is excellent agreement with recent theoretical results when these are shifted by 340~meV in energy.

physics.atom-ph

Testing strong-field QED to second-order in the highly correlated atomic system berylliumlike Pb78+ by electron-ion recombination spectroscopy

A low-energy storage ring with an ultracold electron cooler has been coupled with a heavy-ion accelerator facilitating high-resolution electron-ion collision spectroscopy of the heaviest few-electron ions. In the present work resonant electron-ion recombination of berylliumlike Pb$^{78+}$ ions was measured in the collision-energy range 9.3-16.5eV and a value of 244.937(30) eV is derived for the Pb$^{78+}$($2s^2\;^1S_0 - 2s\,2p\;^3P_1$) excitation energy. This result agrees with the most recent (less accurate) theoretical value of 244.942(52) eV [Malyshev et al., Physical Review A 110, 062824 (2024)], which has been calculated by applying strong-field QED rigorously up to the second order. The present investigation suggests that further technical improvements can potentially increase the experimental accuracy by an order of magnitude.

physics.atom-ph

A Setup to Study Atomic State Population Dynamics and Optical Polarization at CRYRING@ESR

We present a recently established setup for laser spectroscopy at CRYRING@ESR at the GSI Helmholtz Centre for Heavy Ion Research. Here, laser spectroscopy can be performed on stored and cooled ion bunches and coasting beams. First spectra of $^{24,25}$Mg$^+$ ions are presented that were recorded by classical Doppler-limited fluorescence spectroscopy as well as $\Lambda$-spectroscopy using counter- and copropagating laser beams that are Doppler-shifted by several nm.

physics.atom-ph

A high-resolution asymmetric von Hamos spectrometer for low-energy X-ray spectroscopy at the CRYRING@ESR electron cooler

We present research program and project for high-resolution wavelength-dispersive spectrometer dedicated to low-energy X-ray spectroscopy at the electron cooler of the CRYRING@ESR storage ring, which is a part of the international Facility for Antiproton and Ion Research (FAIR) currently being built in Darmstadt. Due to the unique shape of the electorn-ion recombination X-ray source, resulting from the overlapping of the electron and ion beams in the electron cooler, the spectrometer can work in the specific asymmetric von Hamos (AvH) geometry. In order to completely eliminate the influence of Doppler effect on the measured X-ray energies, two asymmetric von Hamos spectrometers will be installed next to the dipole magnets on both sides of the electron cooler to detect blue/red (0$^{\circ}$/180$^{\circ}$) shifted X-rays, e.g. emitted in the radiative recombination (RR) process. The X-ray-tracing Monte-Carlo simulations show that the proposed AvH spectrometer will allow to determine with sub-meV precision, the low-energy X-rays (5-10 keV) emitted from stored bare or few-electron heavy ions interacting with cooling electrons. This experimental precision will enable accurate studies of the quantum electrodynamics (QED) effects in mid-Z H- and He-like ions.

physics.atom-ph

Storage, Accumulation and Deceleration of Secondary Beams for Nuclear Astrophysics

Low-energy investigations on rare ion beams are often limited by the available intensity and purity of the ion species in focus. Here, we present the first application of a technique that combines in-flight production at relativistic energies with subsequent secondary beam storage, accumulation and finally deceleration to the energy of interest. Using the FRS and ESR facilities at GSI, this scheme was pioneered to provide a secondary beam of $^{118}$Te$^{52+}$ for the measurement of nuclear proton-capture at energies of 6 and 7 MeV/u. The technique provided stored beam intensities of about $10^6$ ions at high purity and brilliance, representing a major step towards low-energy nuclear physics studies using rare ion beams.

physics.ins-det

Integration of maXs-type microcalorimeter detectors for high-resolution x-ray spectroscopy into the experimental environment at the CRYRING@ESR electron cooler

We report on the first integration of novel magnetic microcalorimeter detectors (MMCs), developed within SPARC (Stored Particles Atomic Physics Research Collaboration), into the experimental environment of storage rings at GSI, Darmstadt, namely at the electron cooler of CRYRING@ESR. Two of these detector systems were positioned at the 0$^\circ$ and 180$^\circ$ view ports of the cooler section to obtain high-resolution x-ray spectra originating from a stored beam of hydrogen-like uranium interacting with the cooler electrons. While previous test measurements with microcalorimeters at the accelerator facility of GSI were conducted in the mode of well-established stand-alone operation, for the present experiment we implemented several notable modifications to exploit the full potential of this type of detector for precision x-ray spectroscopy of stored heavy ions. Among these are a new readout system compatible with the multi branch system data acquisition platform of GSI, the synchronization of a quasi-continuous energy calibration with the operation cycle of the accelerator facility, as well as the first exploitation of the maXs detectors' time resolution to apply coincidence conditions for the detection of photons and charge-changed ions.

physics.ins-det

Single and double $K$-shell vacancy production in slow Xe$^\textrm{54+,53+}$-Xe collisions

We present an experimental and theoretical study of symmetric $\textrm{Xe}^{54+}+\textrm{Xe}$ collisions at 50, 30, and 15 MeV/u, corresponding to strong perturbations with $v_K/v_\text{p}$ = 1.20, 1.55, and 2.20, respectively ($v_K$: classical $K$-shell orbital velocity, $v_\text{p}$: projectile velocity), as well as $\textrm{Xe}^{53+}+\textrm{Xe}$ collisions at 15 MeV/u. For each of these systems, x-ray spectra were measured under a forward angle of $35^\circ$ with respect to the projectile beam. Target satellite and hypersatellite radiation, $K\alpha_{2,1}^\mathrm{s}$ and $K\alpha_{2,1}^\mathrm{hs}$, respectively, were analyzed and used to derive cross section ratios for double-to-single target $K$-shell vacancy production. We compare our experimental results to relativistic time-dependent two-center calculations.

physics.atom-ph

X-ray emission associated with radiative recombination for Pb$^{82+}$ ions at threshold energies

For bare lead ions, decelerated to the low beam energy of 10 MeV/u, the x-ray emission associated with radiative recombination (RR) at "cold collision" conditions has been studied at the electron cooler of CRYRING@ESR at GSI-Darmstadt. Utilizing dedicated x-ray detection chambers installed at 0{\deg} and 180{\deg} observation geometry, we observed for the very first time for stored ions the full x-ray emission spectrum associated with RR under electron cooling conditions. Most remarkably, no line distortion effects due to delayed emission are present in the well resolved spectra, spanning over a wide range of x-ray energies (from about 5 to 100 keV) which enable to identify fine-structure resolved Lyman, Balmer as well as Paschen x-ray lines along with the RR transitions into the K-, L and M-shell of the ions. To compare with theory, an elaborate theoretical model has been applied. By considering the relativistic atomic structure of Pb$^{81+}$, this model is based on a sophisticated computation of the initial population distribution via RR for all atomic levels up to Rydberg states with principal quantum number $n=$ 165 in combination with cascade calculations based on time-dependent rate equations. Within the statistical accuracy, the experimental x-ray line emission is in very good agreement with the results of the theoretical model applied. Most notably, this comparison sheds light on the contribution of prompt and delayed X-ray emission (up to 70 ns) to the observed X-ray spectra, originating in particular from Yrast transitions into inner shells.

physics.atom-ph

Electron-loss-to-continuum cusp in collisions of U$^{89+}$ with N$_{2}$ and Xe

We study the electron-loss-to-continuum (ELC) cusp experimentally and theoretically by comparing the ionization of U$^{89+}$ projectiles in collisions with N$_2$ and Xe targets, at a beam energy of 75.91 MeV/u. The coincidence measurement between the singly ionized projectile and the energy of the emitted electron is used to compare the shape of the ELC cusp at weak and strong perturbations. A significant energy shift for the centroid of the electron cusp is observed for the heavy target of Xe as compared to the light target of N$_2$. Our results provide a stringent test for fully relativistic calculations of double-differential cross sections performed in the first-order approximation and in the continuum-distorted-wave approach.

physics.atom-ph

Determination of luminosity for in-ring reactions: A new approach for the low-energy domain

Luminosity is a measure of the colliding frequency between beam and target and it is a crucial parameter for the measurement of absolute values, such as reaction cross sections. In this paper, we make use of experimental data from the ESR storage ring to demonstrate that the luminosity can be precisely determined by modelling the measured Rutherford scattering distribution. The obtained results are in good agreement with an independent measurement based on the x-ray normalization method. Our new method provides an alternative way to precisely measure the luminosity in low-energy stored-beam configurations. This can be of great value in particular in dedicated low-energy storage rings where established methods are difficult or impossible to apply.

nucl-ex

Electron capture of Xe$^{54+}$ in collisions with H${_2}$ molecules in the energy range between 5.5 MeV/u and 30.9 MeV/u

The electron capture process was studied for Xe$^{54+}$ colliding with H$_2$ molecules at the internal gas target of the ESR storage ring at GSI, Darmstadt. Cross section values for electron capture into excited projectile states were deduced from the observed emission cross section of Lyman radiation, being emitted by the hydrogen-like ions subsequent to the capture of a target electron. The ion beam energy range was varied between 5.5 MeV/u and 30.9 MeV/u by applying the deceleration mode of the ESR. Thus, electron capture data was recorded at the intermediate and in particular the low collision energy regime, well below the beam energy necessary to produce bare xenon ions. The obtained data is found to be in reasonable qualitative agreement with theoretical approaches, while a commonly applied empirical formula significantly overestimates the experimental findings.

physics.atom-ph

New Test of Modulated Electron Capture Decay of Hydrogen-Like $^{142}$Pm Ions: Precision Measurement of Purely Exponential Decay

An experiment addressing electron capture (EC) decay of hydrogen-like $^{142}$Pm$^{60+}$ ions has been conducted at the experimental storage ring (ESR) at GSI. The decay appears to be purely exponential and no modulations were observed. Decay times for about 9000 individual EC decays have been measured by applying the single-ion decay spectroscopy method. Both visually and automatically analysed data can be described by a single exponential decay with decay constants of 0.0126(7) s$^{-1}$ for automatic analysis and 0.0141(7) s$^{-1}$ for manual analysis. If a modulation superimposed on the exponential decay curve is assumed, the best fit gives a modulation amplitude of merely 0.019(15), which is compatible with zero and by 4.9 standard deviations smaller than in the original observation which had an amplitude of 0.23(4).

nucl-ex

Radiative electron capture as a tunable source of highly linearly polarized x-rays

The radiative electron capture (REC) into the K shell of bare Xe ions colliding with a hydrogen gas target has been investigated. In this study, the degree of linear polarization of the K-REC radiation was measured and compared with rigorous relativistic calculations as well as with the previous results recorded for U$^{92+}$. Owing to the improved detector technology a significant gain in precision of the present polarization measurement is achieved compared to the previously published results. The obtained data confirms that for medium-Z ions such as Xe the REC process is a source of highly polarized x-rays which can easily be tuned with respect to the degree of linear polarization and the photon energy. We argue, in particular, that for relatively low energies the photons emitted under large angles are almost fully linear polarized.

physics.atom-ph

Approaching the Gamow window with stored ions: Direct measurement of $^{124}$Xe(p,$\gamma$) in the ESR storage ring

We report the first measurement of low-energy proton-capture cross sections of $^{124}$Xe in a heavy ion storage ring. $^{124}$Xe$^{54+}$ ions of five different beam energies between 5.5 AMeV and 8 AMeV were stored to collide with a windowless hydrogen target. The $^{125}$Cs reaction products were directly detected. The interaction energies are located on the high energy tail of the Gamow window for hot, explosive scenarios such as supernovae and X-ray binaries. The results serve as an important test of predicted astrophysical reaction rates in this mass range. Good agreement in the prediction of the astrophysically important proton width at low energy is found, with only a 30% difference between measurement and theory. Larger deviations are found above the neutron emission threshold, where also neutron- and ${\gamma}$-widths significantly impact the cross sections. The newly established experimental method is a very powerful tool to investigate nuclear reactions on rare ion beams at low center-of-mass energies.

nucl-ex

Wavelength-dispersive spectroscopy in the hard x-ray regime of a heavy highly-charged ion: The 1s Lamb shift in hydrogen-like gold

Accurate spectroscopy of highly charged high-Z ions in a storage ring is demonstrated to be feasible by the use of specially adapted crystal optics. The method has been applied for the measurement of the 1s Lamb shift in hydrogen-like gold (Au 78+) in a storage ring through spectroscopy of the Lyman x rays. This measurement represents the first result obtained for a high-Z element using high-resolution wavelength-dispersive spectroscopy in the hard x-ray regime, paving the way for sensitivity to higher-order QED effects.

physics.atom-ph

Absolute rate coefficients for photorecombination of berylliumlike and boronlike silicon ions

We report measured rate coefficients for electron-ion recombination for Si10+ forming Si9+ and for Si9+ forming Si8+, respectively. The measurements were performed using the electron-ion merged-beams technique at a heavy-ion storage ring. Electron-ion collision energies ranged from 0 to 50 eV for Si9+ and from 0 to 2000 eV for Si10+, thus, extending previous measurements for Si10+ [Orban et al. 2010, Astrophys. J. 721, 1603] to much higher energies. Experimentally derived rate coefficients for the recombination of Si9+ and Si10+ ions in a plasma are presented along with simple parameterizations. These rate coefficients are useful for the modeling of the charge balance of silicon in photoionized plasmas (Si9+ and Si10+) and in collisionally ionized plasmas (Si10+ only). In the corresponding temperature ranges, the experimentally derived rate coefficients agree with the latest corresponding theoretical results within the experimental uncertainties.

physics.atom-ph