Searcharxiv⌕ Search

arXiv subjects

M. Lisovenko

Publications and source records attributed to M. Lisovenko.

26 records · Page 2Linked to original sources

A portable and high intensity 24 keV neutron source based on $^{124}$Sb-$^{9}$Be photoneutrons and an iron filter

A portable monoenergetic 24 keV neutron source based on the $^{124}$Sb-$^9$Be photoneutron reaction and an iron filter has been constructed and characterized. The coincidence of the neutron energy from SbBe and the low interaction cross-section with iron (mean free path up to 29 cm) makes pure iron specially suited to shield against gamma rays from $^{124}$Sb decays while letting through the neutrons. To increase the $^{124}$Sb activity and thus the neutron flux, a $>$1 GBq $^{124}$Sb source was produced by irradiating a natural Sb metal pellet with a high flux of thermal neutrons in a nuclear reactor. The design of the source shielding structure makes for easy transportation and deployment. A hydrogen gas proportional counter is used to characterize the neutrons emitted by the source and a NaI detector is used for gamma background characterization. At the exit opening of the neutron beam, the characterization determined the neutron flux in the energy range 20-25 keV to be 5.36$\pm$0.20 neutrons per cm$^2$ per second and the total gamma flux to be 213$\pm$6 gammas per cm$^2$ per second (numbers scaled to 1 GBq activity of the $^{124}$Sb source). A liquid scintillator detector is demonstrated to be sensitive to neutrons with incident kinetic energies from 8 to 17 keV, so it can be paired with the source as a backing detector for neutron scattering calibration experiments. This photoneutron source provides a good tool for in-situ low energy nuclear recoil calibration for dark matter experiments and coherent elastic neutrino-nucleus scattering experiments.

physics.ins-det↗

Large area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work we showcase light detectors based on a novel Ir-Pt bilayer transition edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of <100~eV rms. Our detectors have risetimes of $\sim$180 $μ$s and measured timing jitter of <20 $μ$s for the expected signal-to-noise at the Q-value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-beta decay pileup events. The current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

physics.ins-det↗

Light Dark Matter Detection with Hydrogen-rich Crystals and Low-Tc TES Detectors

Direct detection of nuclear scatterings of sub-GeV Dark Matter (DM) particles favors low-Z nuclei. Hydrogen nucleus, which has a single proton, provides the best kinematic match to a light dark matter particle. The characteristic nuclear recoil energy is boosted by a factor of a few tens from those for larger nuclei used in traditional Weakly Interacting Massive Particle (WIMP) searches. Furthermore, hydrogen is optimal not only for spin-independent nuclear scatterings of sub-GeV DM, but also for spin-dependent nuclear scatterings, where large parameter space remains unconstrained. In this paper, we first introduce hydrogen-rich crystals, which include water ice, acetylene, anthracene, trans-stilbene, and naphthalene. These crystals emit two classes of signals under kinetic excitations. One class of the signals is infrared photons, which are from optically active fundamental vibrational modes of molecules and are at corresponding characteristic wavelengths. The other is acoustic phonons, and optical phonons that decay into acoustic phonons. We then discuss the technical status and future researches of low-Tc Transition-Edge Sensor (TES) detectors, which measure single infrared photons and a small flux of acoustic phonons with desirable sensitivities. With theoretical modeling to select the hydrogen-rich crystals for the optimized science reach, development of ultra-sensitive low-Tc TES detectors for readout, and experimentally characterizing transport properties of photons and phonons in the selected hydrogen-rich crystals, a direct detection experiment can be built for measuring the large unexplored parameter space of light DM particles.

physics.ins-det↗

SPT-3G+: Mapping the High-Frequency Cosmic Microwave Background Using Kinetic Inductance Detectors

We present the design and science goals of SPT-3G+, a new camera for the South Pole Telescope, which will consist of a dense array of 34100 kinetic inductance detectors measuring the cosmic microwave background (CMB) at 220 GHz, 285 GHz, and 345 GHz. The SPT-3G+ dataset will enable new constraints on the process of reionization, including measurements of the patchy kinematic Sunyaev-Zeldovich effect and improved constraints on the optical depth due to reionization. At the same time, it will serve as a pathfinder for the detection of Rayleigh scattering, which could allow future CMB surveys to constrain cosmological parameters better than from the primary CMB alone. In addition, the combined, multi-band SPT-3G and SPT-3G+ survey data will have several synergies that enhance the original SPT-3G survey, including: extending the redshift-reach of SZ cluster surveys to $z > 2$; understanding the relationship between magnetic fields and star formation in our Galaxy; improved characterization of the impact of dust on inflationary B-mode searches; and characterizing astrophysical transients at the boundary between mm and sub-mm wavelengths. Finally, the modular design of the SPT-3G+ camera allows it to serve as an on-sky demonstrator for new detector technologies employing microwave readout, such as the on-chip spectrometers that we expect to deploy during the SPT-3G+ survey. In this paper, we describe the science goals of the project and the key technology developments that enable its powerful yet compact design.

astro-ph.IM↗

Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.

astro-ph.IM↗

Scintillation yield from electronic and nuclear recoils in superfluid $^4$He

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

physics.ins-det↗

Strategies for reducing frequency scatter in large arrays of superconducting resonators

Superconducting resonators are now found in a broad range of applications that require high-fidelity measurement of low-energy signals. A common feature across almost all of these applications is the need for increased numbers of resonators to further improve sensitivity, and the ability to read out large numbers of resonators without the need for additional cryogenic complexity is a primary motivation. One of the major limitations of current resonator arrays is the observed scatter in the resonator frequencies when compared to the initial design. Here we present recent progress toward identifying one of the dominant underlying causes of resonator scatter, inductor line width fluctuation. We designed and fabricated an array of lumped-element resonators with inductor line width changing from 1.8um to 2.2um in step of 0.1um defined with electron-beam lithography to probe and quantify the systematic variation of resonance frequency across a 6-inch wafer. The resonators showed a linear frequency shift of 20MHz (140FWHM) and 30MHz (214FWHM), respectively, as they are connected to two different capacitors. This linear relationship matches our theoretical prediction. The widely used MLA photon lithography facility for MKID fabrication has a resolution on the order of 600nm, which could cause frequency fluctuation on the order of 100MHz or 710FWHM.

cond-mat.supr-con↗

Performance of a low-parasitic frequency-domain multiplexing readout

Frequency-domain multiplexing is a readout technique for transition edge sensor bolometer arrays used on modern CMB experiments, including the SPT-3G receiver. Here, we present design details and performance measurements for a low-parasitic frequency-domain multiplexing readout. Reducing the parasitic impedance of the connections between cryogenic components provides a path to improving both the crosstalk and noise performance of the readout. Reduced crosstalk will in turn allow higher multiplexing factors. We have demonstrated a factor of two improvement in parasitic resistance compared to SPT-3G hardware. Reduced parasitics also permits operation of lower-resistance bolometers, which enables better optimization of R$_{\rm{bolo}}$ for improved readout noise performance. The prototype system exhibits noise performance comparable to SPT-3G readout hardware when operating SPT-3G detectors.

astro-ph.IM↗