SearcharxivSearch

arXiv subjects

M. Lisowska

Publications and source records attributed to M. Lisowska.

At least 19 recordsLinked to original sources

Advances in photocathode development for PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector that combines a Cherenkov radiator, a~semi-transparent photocathode and a Micromegas amplification stage, targeting time resolutions of tens of picoseconds for minimum ionising particles (MIPs). Initial single-pad prototypes achieved time resolutions of $\sigma<25$ ps, demonstrating strong potential for High Energy Physics (HEP) applications and beyond. The objective of this paper is a comprehensive characterisation of photocathodes, with a strong focus on robust materials while preserving excellent timing performance. The study includes laboratory measurements of optical and resistive properties, along with beam tests using 150 GeV/$c$ muons to evaluate the time resolution and photoelectron yield for various photocathodes. The best performance was obtained by a 5 nm Cesium Iodide (CsI) photocathode, reaching $\sigma = 10.9 \pm 0.3$ ps with more than 30 extracted photoelectrons, representing the most precise time resolution achieved by PICOSEC Micromegas to date. Metallic and carbon-based photocathodes, including Titanium (Ti), Boron Carbide (B$_4$C) and Diamond-Like Carbon (DLC), were also tested, with Ti and B$_4$C emerging as the most promising alternatives, achieving $\sigma \approx 30$ ps with about 5 extracted photoelectrons. These results demonstrate that improved robustness can be achieved while maintaining excellent time resolution, supporting the feasibility of using the PICOSEC Micromegas concept in future experiments.

physics.ins-det

Optical readout of MPGDs with solid wavelength shifters

Optical readout of MicroPattern Gaseous Detectors (MPGDs) makes use of the high granularity of imaging sensors to achieve good spatial resolution for radiation imaging and particle detection. CF4 is widely used as a scintillating gas because its emission lies in the visible range, where optical sensors are most sensitive. However, to reduce reliance on greenhouse gas, such as CF4, which also has limited availability, alternative gas mixtures emitting scintillation light in the ultraviolet range can be used in combination with wavelength shifters. We investigate the spatial resolution achievable with optically read out Gaseous Electron Multipliers (GEMs) and Micromegas when using solid wavelength shifter layers such as Tetraphenyl butadiene (TPB). TPB coatings on the anode of glass Micromegas achieve the best spatial resolution of 0.22 mm owing to the minimal distance between the origin of the scintillation light and the wavelength shifter. Nevertheless, TPB layers were also shown to achieve moderate spatial resolution in combination with optically read out GEMs.

physics.ins-det

Timing performance of large prototype based on $\upmu$RWELL- PICOSEC detector technology with $10 \times 10\ \mathrm{cm}^{2}$ active area

The $\upmu$RWELL-PICOSEC detector, which combines a $\upmu$RWELL gaseous amplification structure with a Cherenkov radiator and photocathode, is a novel approach to acheive fast and precise timing in gaseous detectors. With timing precision at the level of tens of picoseconds, this technology is particularly suited for time-of-flight (TOF) applications in particle physics and potentially medical imaging. Beam tests with a 150~GeV/$c$ muon beam have been carried out on a large-area (10~$\times$~10~cm$^{2}$) prototype equipped with a cesium iodide (CsI) photocathode. Using an oscilloscope-based single-channel readout, timing measurements on two individual pads of the detector have yielded resolutions of $\approx$ 48 ps and $\approx$ 52 ps under different biasing conditions respectively.

physics.ins-det

Spatial resolution improvement of PICOSEC Micromegas precise timing detectors

The combination of a Cherenkov radiator with a semi-transparent photocathode and a Micromegas based amplification stage allows PICOSEC Micromegas detectors to achieve a time resolution of better than 15ps. While tileable prototypes with 10x10 channels feature 1x1 cm^2 readout pads, finer readout granularity can be used to improve the spatial resolution. We report on the study of high readout granularity PICOSEC Micromegas prototypes which achieve around 0.5mm spatial resolution with 3.5mm large pads. No significant improvement was found when readout pad size was further reduced to 2.2mm. The timing resolution of the leading pad was found to be slightly degraded but remained better than 20ps for a medium granularity prototype. The achieved spatial resolution can enable PICOSEC Micromegas to be used as precise timing and moderate resolution tracking detector simultaneously.

physics.ins-det

Design and Performance of a 96-channel Resistive PICOSEC Micromegas Detector for ENUBET

The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector that achieves picosecond-level timing by coupling a Cherenkov radiator, typically an MgF2 crystal, to a Micromegas-based photodetector with a photocathode. This configuration allows the fast photoelectron-induced signal to suppress the intrinsic time jitter of gaseous detectors, enabling sub-20 ps timing precision while preserving the robustness and scalability of micro-pattern gaseous detector technologies. The 96-pad PICOSEC-MM detector is a large-area demonstrator optimized for precision timing in high-energy physics, building on research and development insights from earlier 7-pad resistive prototypes to validate scalability, uniformity, and robustness for the ENUBET project. It employs a 2.5 nm diamond-like carbon photocathode and a Micromegas board with a surface resistivity of 10 megaohms per square, and was characterized using 150 GeV/c muons at the CERN SPS beamline, with one-third of the active area instrumented per run. A dedicated alignment procedure for multi-pad PICOSEC-MM systems was used to reconstruct pad centers and merge measurements across regions, yielding a timing resolution of 43 ps and uniform signal arrival time distributions over the tested area. Mechanical flatness was identified as a key factor, with planarity tolerances within 10 micrometers required to maintain good timing resolution, and the successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept toward robust, high-granularity, picosecond-level gaseous timing detectors for monitored neutrino beam experiments such as ENUBET.

physics.ins-det

Performance Optimization and Characterization of 7-pad Resistive PICOSEC Micromegas Detectors

We present a comprehensive characterization of resistive PICOSEC Micromegas detector prototypes, tested under identical conditions, constant drift gap, field configurations, and photocathode at the CERN SPS H4 beam line. This work provides a proof of concept for the use of resistive layer technology in gaseous timing detectors, demonstrating that robustness can be improved without compromising the excellent timing performance of PICOSEC Micromegas. Different resistive architectures and values were explored to optimize stability and ensure reliable long-term operation in challenging experimental environments. The prototype with a 10M{\Omega} resistive layer achieved the best overall performance, with a timing resolution of 22.900 {\pm} 0.002 ps and a spatial resolution of 1.190 {\pm} 0.003 mm, while charge sharing across multiple pads enabled combined timing resolutions below 28 ps. A lower-resistivity (200k{\Omega}) configuration exhibited enhanced charge spread, leading to minor systematic offsets in reconstructed pad centers, yet maintained robust timing and spatial performance. Capacitive charge-sharing architectures improved spatial resolution in some regions but suffered from signal attenuation and nonuniform charge distributions, resulting in slightly degraded timing (33.300 {\pm} 0.002 ps) and complex localization patterns. Mechanical precision, particularly readout planarity and photocathode alignment, was identified as critical for uniform detector response. These studies benchmark the potential of resistive layers for gaseous timing detectors and provide a foundation for scalable designs with optimized timing and spatial resolution across diverse experimental applications.

physics.ins-det

Nanodiamond photocathodes for MPGD-based single photon detectors

This study investigates the suitability of Hydrogenated NanoDiamond (HND) materials as an alternative for CsI in MPGD-based photon detectors. The research focuses on characterizing HND photocathodes coupled with THGEM + Micromegas-based detectors. The HND grains were prepared via hydrogenation and stored in water for more than two years. They were then coated on PCB discs or THGEMs using a pulsed spray technique. The resulting quantum efficiency (QE) values (~4% at 122 nm) were found to be within a factor of 10 of the best freshly hydrogenated samples reported in the literature ( ~40% at 120 nm). The robustness of reflective HND photocathodes against ion bombardment was measured to be about 10 times larger than the corresponding CsI one after the same charge accumulation. Furthermore, THGEM characterization indicates minimal alteration in response after HND coatings. These results suggest that HND holds potential as a more robust photocathode for gaseous detectors, offering improved performance in single-photon detection applications.

physics.ins-det

Overlap-aware segmentation for topological reconstruction of obscured objects

The separation of overlapping objects presents a significant challenge in scientific imaging. While deep learning segmentation-regression algorithms can predict pixel-wise intensities, they typically treat all regions equally rather than prioritizing overlap regions where attribution is most ambiguous. Recent advances in instance segmentation show that weighting regions of pixel overlap in training can improve segmentation boundary predictions in regions of overlap, but this idea has not yet been extended to segmentation regression. We address this with Overlap-Aware Segmentation of ImageS (OASIS): a new segmentation-regression framework with a weighted loss function designed to prioritize regions of object-overlap during training, enabling extraction of pixel intensities and topological features from heavily obscured objects. We demonstrate OASIS in the context of the MIGDAL experiment, which aims to directly image the Migdal effect--a rare process where electron emission is induced by nuclear scattering--in a low-pressure optical time projection chamber. This setting poses an extreme test case, as the target for reconstruction is a faint electron recoil track which is often heavily-buried within the order(s)-of-magnitude brighter nuclear recoil track. Compared to unweighted segmentation regression, we demonstrate OASIS's novel overlap region-targeted loss function weight to be the single most important training weight for improving intensity and topological reconstructions of the low-energy electron tracks that tend to be most dominated by pixel overlap. Averaging over eight training campaigns, we further show the addition of overlap-targeted weights to improve median intensity reconstruction errors from -41.1% to -13.3% for these low-energy electrons. These performance gains demonstrate OASIS as a generalizable methodology for recovering obscured signals in overlap-dominated regions.

hep-ex

Measurements of enriched 155 Gd and 157Gd converters with the NMX detector on the nTOF EAR2 beam line at CERN

The detectors for the NMX instrument at the European Spallation Source (ESS) in Lund use natural Gd as the neutron converter. In 2024, beam time was obtained at the neutron time-of flight experiment (nTOF) at CERN to study the feasibility of an upgrade to enriched Gd. A 10 x 10 cm^2 prototype of the NMX detector was equipped with two enriched Gd samples (157Gd and 155Gd) that were attached with copper tape to the natural Gd cathode of the detector. Three sets of measurements were taken, with the beam focused on either the natural Gd, the 157Gd, or the 155Gd samples. Using the time-of-flight technique with the subsequent conversion of time-of-flight into energy, the resonant region between 1 eV and 200 eV of the 157Gd and 155Gd cross sections was studied. The peaks in the resonant region were clearly visible, having higher ADC values in the ADC spectrum. Additionally, the resonant peaks had a larger number of counts per energy bin. In the thermal neutron energy range, the count rate at the center of the beam was measured for natural Gd, 157Gd, and 155Gd. Enriched 157Gd showed an efficiency that was between 60 - 180% higher, compared to natural Gd, for neutron wavelengths between 0.8 A and 1.8 A. The measured 60 % increase in efficiency at 1.8 A is lower than expected from simulations (100 %) and previous measurements with solid state detectors (80 %). Gamma background detection, bad focusing, and saturation effects most likely explain this deviation. An upgrade of the natural Gd converter to enriched 157Gd would thus lead to an efficiency increase of at least 60 %. The measurements presented in this paper are the first successful time-of-flight measurements with the NMX detector prototype and the ESS VMM readout.

physics.ins-det

Embedding the Timepix4 in Micro-Pattern Gaseous Detectors

The combination of Micro-Pattern Gaseous Detectors (MPGDs) and pixel charge readout enables specific experimental opportunities. Using the Timepix4 for the readout is advantageous because of its size (around 7 cm^2 active area) and its Through Silicon Vias. The latter enables to connect to the Timepix4 from the back side. Thus, it can be tiled on four sides, allowing it to cover large areas without loss of active area. Here, the first results of reading out MPGDs with the Timepix4 are presented. Measurements with a Gas Electron Multiplier (GEM) detector show that event selection based on geometrical parameters of the interaction is possible, X-ray imaging studies can be performed, as well as energy and time-resolved measurements. In parallel, the embedding of a Timepix4 into a micro-resistive Well (uRWell) amplification structure is explored. The first mechanical tests have been successful. The status of the electrical functionality is presented, as well as simulation studies on the signal induction in such a device.

physics.ins-det

Application of the VMM3a/SRS: A t0-less TWIN GEM-based TPC

Integrating the ATLAS/BNL VMM3a ASIC (Application Specific Integrated Circuit) into the RD51/SRS (Scalable Readout System) provides a self-triggered continuous readout system for various gaseous detectors. Since the system allows flexible parameters, such as switching the polarity, adjusting electronics gain or different peaking times, the settings can be adjusted for a wide range of detectors. The system allows particles to be recorded with a MHz interaction rate in energy, space, and time. The system will be introduced in the beginning, and short examples will be given for different applications. After, the Twin GEM TPC will be discussed in more detail to show the benefits of such a trigger-less system in combination with the Twin configuration. Last, a few results for the tracking performance and the possibility to operate as a tracking telescope will be shown. Thus, this presents the possibility of an extremely low material budget tracking system suitable for tracking from high to low-energy particle beams.

physics.ins-det

The Ultra-Low material budget GEM based TPC for tracking with VMM3a readout

The Gaseous Electron Multiplier-based Time Projection Chamber (GEM-TPC) in TWIN configuration for particle tracking has been consolidated after extensive investigations in different facilities to study its tracking performance. The most attractive feature of this detector is its ultra-low material budget, which is 0.28\% X/X$_0$ and can be further reduced by decreasing the thickness of the gas traversed by the incident particles. Thus, it provides excellent position reconstruction and reduced multi-scattering. This detector consists of two GEM-TPCs with drift fields in opposite directions, achieved by rotating one 180 degrees in the middle plane with respect to the other. These two GEM-TPCs share the same gas volume, i.e., inside a single vessel. This configuration is called a TWIN configuration. The results presented in this work were measured using the newly integrated VMM3a/SRS readout electronics, an important milestone in improving overall performance and capabilities. In 2024, this detector was tested at the H4 beamline of the SPS at CERN, using muons and pions and with different gas mixtures like, for instance: Ar/CO$_2$ (70/30 \%), He/CO$_2$ (70/30 \%) and He/CO$_2$ (90/10 \%). The helium-based mixtures were used to commission the detector to track low momenta muons required in the PSI muon-induced X-ray emission (MIXE) experiment. The results obtained from these measurements, a brief discussion of the methodology used for the data analysis, and a comparison of the spatial resolution for different gas mixtures will be presented.

physics.ins-det

PICOSEC Micromegas Precise-timing Detectors: Development towards Large-Area and Integration

PICOSEC Micromegas (MM) is a precise timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and an MM amplifying structure. The detector conceprt was successfully demonstrated through a single-channel prototype, achieving sub-25 ps time resolution with Minimum Ionizing Particles (MIPs). A series of studies followed, aimed at developing robust, large-area, and scalable detectors with high time resolution, complemented by specialized fast-response readout electronics. This work presents recent advancements towards large-area resistive PICOSEC MM, including 10 $\times$ 10 $\text{cm}^2$ area prototypes and a 20 $\times$ 20 $\text{cm}^2$ prototype, which features the jointing of four photocathodes. The time resolution of these detector prototypes was tested during the test beam, achieved a timing performance of around 25 ps for individual pads in MIPs. Meanwhile, customized electronics have been developed dedicated to the high-precision time measurement of the large-area PICOSEC MM. The performance of the entire system was evaluated during the test beam, demonstrating its capability for large-area integration. These advancements highlight the potential of PICOSEC MM to meet the stringent requirements of future particle physics experiments.

physics.ins-det

Towards MPGDs with embedded pixel ASICs

Combining gaseous detectors with a high-granularity pixelated charge readout enables experimental applications which otherwise could not be achieved. This includes high-resolution tracking of low-energetic particles, requiring ultra-low material budget, X-ray polarimetry at low energies ($\lessapprox$ 2 keV) or rare-event searches which profit from event selection based on geometrical parameters. In this article, the idea of embedding a pixel ASIC - specifically the Timepix4 - into a micro-pattern gaseous amplification stage is illustrated. Furthermore, the first results of reading out a triple-GEM detector with the Timepix4 (GEMPix4) are shown, including the first X-ray images taken with a Timepix4 utilising Through Silicon Vias (TSVs). Lastly, a new readout concept is presented, called the 'Silicon Readout Board', extending the use of pixel ASICs to read out gaseous detectors to a wider range of HEP applications.

physics.ins-det

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30 ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20 ps respectively.

physics.ins-det

Spatial resolution studies using point spread function extraction in optically read out Micromegas and GEM detectors

Optically read out gaseous detectors are used in track reconstruction and imaging applications requiring high granularity images. Among resolution-determining factors, the amplification stage plays a crucial role and optimisations of detector geometry are pursued to maximise spatial resolution. To compare MicroPattern Gaseous Detector (MPGD) technologies, focused low-energy X-ray beams at the SOLEIL synchrotron facility were used to record and extract point spread function widths with Micromegas and GEM detectors. Point spread function width of $\approx$108\,\microns for Micromegas and $\approx$127\,\microns for GEM foils were extracted. The scanning of the beam with different intensities, energies and across the detector active region can be used to quantify resolution-limiting factors and improve imaging detectors using MPGD amplification stages.

physics.ins-det

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a~precise-timing gaseous detector based on a~Cherenkov radiator coupled with a~semi-transparent photocathode and a~Micromegas amplifying structure, targeting a~time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a~time resolution below 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B4C), is pursued. Results from prototypes equipped with DLC and B4C photocathodes exhibited a~time resolution of approximately 32 ps and 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

physics.ins-det

A Novel Diamond-like Carbon based photocathode for PICOSEC Micromegas detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector based on a MM detector operating in a two-stage amplification mode and a Cherenkov radiator. Prototypes equipped with cesium iodide (CsI) photocathodes have shown promising time resolutions as precise as 24 picoseconds (ps) for Minimum Ionizing Particles. However, due to the high hygroscopicity and susceptibility to ion bombardment of the CsI photocathodes, alternative photocathode materials are needed to improve the robustness of PICOSEC MM. Diamond-like Carbon (DLC) film have been introduced as a novel robust photocathode material, which have shown promising results. A batch of DLC photocathodes with different thicknesses were produced and evaluated using ultraviolet light. The quantum efficiency measurements indicate that the optimized thickness of the DLC photocathode is approximately 3 nm. Furthermore, DLC photocathodes show good resistance to ion bombardment in aging test compared to the CsI photocathode. Finally, a PICOSEC MM prototype equipped with DLC photocathodes was tested in muon beams. A time resolution of around 42 ps with a detection efficiency of 97% for 150 GeV/c muons were obtained. These results indicate the great potential of DLC as a photocathode for the PICOSEC MM detector.

physics.ins-det