SearcharxivSearch

arXiv subjects

M. Macko

Publications and source records attributed to M. Macko.

14 recordsLinked to original sources

Fabrication of thin planar radiopure foils with 82Se for the SuperNEMO Demonstrator

The SuperNEMO Demonstrator, designed to search for double beta decay using enriched 82Se, has been assembled in the Modane Underground Laboratory under the French Alps. Thin foils with radio - purified and enriched 82Se are installed centrally in the detector. A novel foil fabrication method has been developed, improving the radiopurity achieved in the previous generation experiment. It consists of wrapping standalone selenium pads in raw Mylar, combined with selenium purified by a new reverse-chromatography method. This paper describes the features of these foils, their fabrication process, the characterization results, and the integration of the foils into the SuperNEMO Demonstrator.

physics.ins-det

Observation of a low energy nuclear recoil peak in the neutron calibration data of an Al$_{2}$O$_{3}$ crystal in CRESST-III

The current generation of cryogenic solid state detectors used in direct dark matter and CE\textnu NS searches typically reach energy thresholds of $\mathcal{O}$(10)$\,$eV for nuclear recoils. For a reliable calibration in this energy regime a method has been proposed, providing mono-energetic nuclear recoils at low energies $\sim\,$100$\,$eV$\,$-$\,$1$\,$keV. In this work we report on the observation of a peak at (1113.6$^{+6.5}_{-6.5}$)$\,$eV in the data of an Al$_{2}$O$_{3}$ crystal in CRESST-III, which was irradiated with neutrons from an AmBe calibration source. We attribute this mono-energetic peak to the radiative capture of thermal neutrons on $^{27}$Al and the subsequent de-excitation via single $\gamma$-emission. We compare the measured results with the outcome of Geant4 simulations and investigate the possibility to make use of this effect for the energy calibration of Al$_{2}$O$_{3}$ detectors at low energies. We further investigate the possibility of a shift in the expected energy scale of this effect caused by the creation of defects in the target crystal.

physics.ins-det

The Impact of Helium Exposure on the PMTs of the SuperNEMO Experiment

The performance of Hamamatsu 8" photomultiplier tubes (PMTs) of the type used in the SuperNEMO neutrinoless double-beta decay experiment (R5912-MOD), is investigated as a function of exposure to helium (He) gas. Two PMTs were monitored for over a year, one exposed to varying concentrations of He, and the other kept in standard atmospheric conditions as a control. Both PMTs were exposed to light signals generated by a Bi-207 radioactive source that provided consistent large input PMT signals similar to those that are typical of the SuperNEMO experiment. The energy resolution of PMT signals corresponding to 1 MeV energy scale determined from the Bi-207 decay spectrum, shows a negligible degradation with He exposure; however the rate of after-pulsing shows a clear increase with He exposure, which is modelled and compared to diffusion theory. A method for reconstructing the partial pressure of He within the PMT and a method for determining the He breakdown point, are introduced. The implications for long-term SuperNEMO operations are briefly discussed.

physics.ins-det

Calorimeter commissioning of the SuperNEMO Demonstrator

The SuperNEMO experiment is searching for neutrinoless double beta decay of \textsuperscript{82}Se, with the unique combination of a tracking detector and a segmented calorimeter. This feature allows to detect the two electrons emitted in the decay and measure their individual energy and angular distribution. The SuperNEMO calorimeter consists of 712 plastic scintillator blocks readout by large PMTs. After the construction of the demonstrator calorimeter underground, we have performed its first commissioning using $\gamma$-particles from calibration sources or from the ambient radioactive background. This article presents the quality assurance tests of the SuperNEMO demonstrator calorimeter and its first time and energy calibrations, with the associated methods.

physics.ins-det

Simulation of a radial TPC for the detection of neutrinoless double beta decay

To search for $\beta\beta0\nu$ decay with unprecedented sensitivity, the R2D2 collaboration is developing a radial time projection chamber with a fiducial mass of half a tonne of $^{136}$Xe at high pressure. The various approaches implemented to eliminate the radioactive background are presented in terms of detector design, topological recognition of interactions, and event energy reconstruction. The developed tools enable the disentangling of the sought-after signal from the background. The projected sensitivity after ten years of data taking yields a half-life limit exceeding $10^{27}$ years, along with a constraint on the effective neutrino mass $m_{\beta\beta}$ that could cover a large fraction of the inverted mass hierarchy region, depending on the final experimental background.

physics.ins-det

Measurement of double-$\beta$ decay of $^{150}$Nd to the 0$^+_1$ excited state of $^{150}$Sm in NEMO-3

The NEMO-3 results for the double-$\beta$ decay of $^{150}$Nd to the 0$^+_1$ and 2$^+_1$ excited states of $^{150}$Sm are reported. The data recorded during 5.25 yr with 36.6 g of the isotope $^{150}$Nd are used in the analysis. For the first time, the signal of the $2\nu\beta\beta$ transition to the 0$^+_1$ excited state is detected with a statistical significance exceeding 5$\sigma$. The half-life is measured to be $T_{1/2}^{2\nu\beta\beta}(0^+_1) = \left[ 1.11 ^{+0.19}_{-0.14} \,\left(\mbox{stat}\right) ^{+0.17}_{-0.15}\, \left(\mbox{syst}\right) \right] \times10^{20}\,\mbox{yr}$. The limits are set on the $2\nu\beta\beta$ decay to the 2$^+_1$ level and on the $0\nu\beta\beta$ decay to the 0$^+_1$ and 2$^+_1$ levels of $^{150}$Sm.

nucl-ex

Measurement of the distribution of $^{207}$Bi depositions on calibration sources for SuperNEMO

The SuperNEMO experiment will search for neutrinoless double-beta decay ($0\nu\beta\beta$), and study the Standard-Model double-beta decay process ($2\nu\beta\beta$). The SuperNEMO technology can measure the energy of each of the electrons produced in a double-beta ($\beta\beta$) decay, and can reconstruct the topology of their individual tracks. The study of the double-beta decay spectrum requires very accurate energy calibration to be carried out periodically. The SuperNEMO Demonstrator Module will be calibrated using 42 calibration sources, each consisting of a droplet of $^{207}$Bi within a frame assembly. The quality of these sources, which depends upon the entire $^{207}$Bi droplet being contained within the frame, is key for correctly calibrating SuperNEMO's energy response. In this paper, we present a novel method for precisely measuring the exact geometry of the deposition of $^{207}$Bi droplets within the frames, using Timepix pixel detectors. We studied 49 different sources and selected 42 high-quality sources with the most central source positioning.

physics.ins-det

Search for Periodic Modulations of the Rate of Double-Beta Decay of $^{100}$Mo in the NEMO-3 Detector

Double-beta decays of $^{100}$Mo from the 6.0195-year exposure of a 6.914 kg high-purity sample were recorded by the NEMO-3 experiment that searched for neutrinoless double-beta decays. These ultra-rare transitions to $^{100}$Ru have a half-life of approximately $7\times10^{18}$ years, and have been used to conduct the first ever search for periodic variations of this decay mode. The Lomb-Scargle periodogram technique, and its error-weighted extension, were employed to look for periodic modulations of the half-life. Monte Carlo modeling was used to study the modulation sensitivity of the data over a broad range of amplitudes and frequencies. Data show no evidence of modulations with amplitude greater than 2.5% in the frequency range of $0.33225\,{\rm y^{-1}}$ to $365.25\,{\rm y^{-1}}$.

nucl-ex

Search for the double-beta decay of 82Se to the excited states of 82Kr with NEMO-3

The double-beta decay of 82Se to the 0+1 excited state of 82Kr has been studied with the NEMO-3 detector using 0.93 kg of enriched 82Se measured for 4.75 y, corresponding to an exposure of 4.42 kg y. A dedicated analysis to reconstruct the gamma-rays has been performed to search for events in the 2e2g channel. No evidence of a 2nbb decay to the 0+1 state has been observed and a limit of T2n 1/2(82Se; 0+gs -> 0+1) > 1.3 1021 y at 90% CL has been set. Concerning the 0nbb decay to the 0+1 state, a limit for this decay has been obtained with T0n 1/2(82Se; 0+g s -> 0+1) > 2.3 1022 y at 90% CL, independently from the 2nbb decay process. These results are obtained for the first time with a tracko-calo detector, reconstructing every particle in the final state.

physics.ins-det

Detailed studies of $^{100}$Mo two-neutrino double beta decay in NEMO-3

The full data set of the NEMO-3 experiment has been used to measure the half-life of the two-neutrino double beta decay of $^{100}$Mo to the ground state of $^{100}$Ru, $T_{1/2} = \left[ 6.81 \pm 0.01\,\left(\mbox{stat}\right) ^{+0.38}_{-0.40}\,\left(\mbox{syst}\right) \right] \times10^{18}$ y. The two-electron energy sum, single electron energy spectra and distribution of the angle between the electrons are presented with an unprecedented statistics of $5\times10^5$ events and a signal-to-background ratio of ~80. Clear evidence for the Single State Dominance model is found for this nuclear transition. Limits on Majoron emitting neutrinoless double beta decay modes with spectral indices of n=2,3,7, as well as constraints on Lorentz invariance violation and on the bosonic neutrino contribution to the two-neutrino double beta decay mode are obtained.

nucl-ex

Calorimeter development for the SuperNEMO double beta decay experiment

SuperNEMO is a double-$β$ decay experiment, which will employ the successful tracker-calorimeter technique used in the recently completed NEMO-3 experiment. SuperNEMO will implement 100 kg of double-$β$ decay isotope, reaching a sensitivity to the neutrinoless double-$β$ decay ($0νββ$) half-life of the order of $10^{26}$ yr, corresponding to a Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of the SuperNEMO detector development programme has been to reach a calorimeter energy resolution, $Δ$E/E, around 3%/$sqrt(E)$(MeV) $σ$, or 7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter composed of large volume plastic scintillator blocks coupled to photomultiplier tubes. We describe the R\&D programme and the final design of the SuperNEMO calorimeter that has met this challenging goal.

physics.ins-det

The BiPo-3 detector for the measurement of ultra low natural radioactivities of thin materials

The BiPo-3 detector, running in the Canfranc Underground Laboratory (Laboratorio Subterráneo de Canfranc, LSC, Spain) since 2013, is a low-radioactivity detector dedicated to measuring ultra low natural radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi ($^{238}$U chain) in thin materials. The total sensitive surface area of the detector is 3.6 m$^2$. The detector has been developed to measure radiopurity of the selenium double $β$-decay source foils of the SuperNEMO experiment. In this paper the design and performance of the detector, and results of the background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and validation of the BiPo-3 measurement with a calibrated aluminium foil is discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of the first enriched $^{82}$Se foils of the double $β$-decay SuperNEMO experiment are reported. The sensitivity of the BiPo-3 detector for the measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$ $μ$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $μ$Bq/kg (90\% C.L.) after 6 months of measurement.

physics.ins-det

Search for neutrinoless quadruple-$β$ decay of $^{150}$Nd with the NEMO-3 detector

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-$β$ decay of $^{150}$Nd using a total exposure of $0.19$ kg$\cdot$y recorded with the NEMO-3 detector at the Modane Underground Laboratory (LSM). We find no evidence of this decay and set lower limits on the half-life in the range $T_{1/2}>(1.1-3.2)\times10^{21}$ y at the $90\%$ CL, depending on the model used for the kinematic distributions of the emitted electrons.

hep-ex

Measurement of the $2νββ$ Decay Half-Life and Search for the $0νββ$ Decay of $^{116}$Cd with the NEMO-3 Detector

The NEMO-3 experiment measured the half-life of the $2νββ$ decay and searched for the $0νββ$ decay of $^{116}$Cd. Using $410$ g of $^{116}$Cd installed in the detector with an exposure of $5.26$ y, ($4968\pm74$) events corresponding to the $2νββ$ decay of $^{116}$Cd to the ground state of $^{116}$Sn have been observed with a signal to background ratio of about $12$. The half-life of the $2νββ$ decay has been measured to be $ T_{1/2}^{2ν}=[2.74\pm0.04\mbox{(stat.)}\pm0.18\mbox{(syst.)}]\times10^{19}$ y. No events have been observed above the expected background while searching for $0νββ$ decay. The corresponding limit on the half-life is determined to be $T_{1/2}^{0ν} \ge 1.0 \times 10^{23}$ y at the $90$ % C.L. which corresponds to an upper limit on the effective Majorana neutrino mass of $\langle m_ν \rangle \le 1.4-2.5$ eV depending on the nuclear matrix elements considered. Limits on other mechanisms generating $0νββ$ decay such as the exchange of R-parity violating supersymmetric particles, right-handed currents and majoron emission are also obtained.

hep-ex