SearcharxivSearch

arXiv subjects

M. Makela

Publications and source records attributed to M. Makela.

At least 19 recordsLinked to original sources

High voltage and electrode system for a cryogenic experiment to search for the neutron electric dipole moment

The cryogenic approach to the search for the neutron electric dipole moment--performing the experiment in superfluid liquid helium--holds promise for a substantial increase in sensitivity, potentially enabling a sensitivity level of $10^{-28}$ e-cm. A crucial component in realizing such an experiment is the high voltage and electrode system capable of providing an electric field of 75 kV/cm. This, in turn, requires an electric potential of 635 kV to be applied to the high voltage electrode, while simultaneously satisfying other experimental constraints, such as those on heat load and magnetic noise requirements. This paper describes the outcome of a comprehensive development program addressing these challenges. It outlines the system requirements, discusses new insights into relevant physical phenomena, and details selected technical solutions with their corresponding experimental demonstrations and expected performance. The results collectively demonstrate the successful development of the necessary technology for the high-voltage and electrode system for this approach.

physics.ins-det

From Commissioning to Precision Data-Taking: Resolving Operational Challenges in the Nab Detector Systems

Our understanding of the weak mixing of quarks, described by the Cabibbo Kobayashi Maskawa (CKM) matrix, currently presents an anomaly. Thanks to major strides in both theory and experiment, improved precision in determinations of the first row of matrix elements has revealed disagreement with the expectation of unitarity. The Nab experiment at the Spallation Neutron Source is designed to precisely extract the first matrix element $V_{ud}$ and shed light on experimental tensions within the neutron beta decay dataset. Nab's asymmetric spectrometer allows coincident reconstruction of the decay proton and electron energies, which will be used to determine the electron-neutrino correlation coefficient, and thus (with the neutron lifetime) determine $V_{ud}$. This unique approach has provided a more comprehensive view of neutron beta decay, including a first observation of the full momentum phase space of the decay above detector thresholds and limits on exotic neutron states. Recent upgrades to the Nab detector system have improved the robustness and stability of the detector performance in terms of proton detection efficiency, noise performance, and detector segment availability, setting the stage for high precision physics data-taking.

physics.ins-det

Detection of ultracold neutrons with powdered scintillator screens

Zinc sulfide (ZnS:Ag) scintillators coated with a thin 10B layer are widely used for ultracold neutron (UCN) detection, but their application is limited by long decay times and significant phosphorescence. We investigated two possible replacement scintillators: yttrium aluminum perovskite (YAP:Ce) and lutetium ttrium orthosilicate (LYSO:Ce). Both exhibit decay times on the order of 30-40 ns, which can help reduce dead time in high-count-rate experiments. YAP:Ce showed approximately 60% lower phosphorescence than ZnS:Ag after 2 days and detected about 20% more UCN. In contrast, LYSO:Ce exhibited higher phosphorescence and produced fewer UCN counts compared to both ZnS:Ag and YAP:Ce. While both tested scintillators are capable UCN detectors, YAP:Ce consistently outperformed LYSO:Ce across all measured performance metrics.

physics.ins-det

Development of Two-Dimensional Neutron Imager with a Sandwich Configuration

We have developed a two-dimensional neutron imager based on a semiconductor pixelated sensor, especially designed for experiments measuring of a spatial and a temporal behavior of quantum bound states of ultra-cold neutrons. Through these measurements, we expect to measure the ratio between the inertial and gravitational masses of neutrons and to test the equivalence principle in the quantum regime. As one of the principal neutron imagers, we fabricated a sensor with a sandwich configuration, named 10B-INTPIX4-sw, and tested its response to ultra-cold neutrons at the Los Alamos Neutron Science Center (LANSCE). We observed simultaneous events on both sandwiching sensors without significant loss of detection efficiency. The efficiency was evaluated to be about 16%, relative to the 10B/ZnS reference detector. The coincidence condition reduces its efficiency by a factor of about 3.

physics.ins-det

YAP:Ce scintillator as an absolute ultracold neutron detector

The upcoming UCNProBe experiment at Los Alamos National Laboratory will measure the $\beta$-decay rate of free neutrons with different systematic uncertainties than previous beam-based neutron lifetime experiments. We have developed a new $^{10}$B-coated YAP:Ce scintillator whose properties are presented. The advantage of the YAP:Ce scintillator is its high Fermi potential, which reduces the probability for upscattering of ultracold neutrons, and its short decay time, which is important at high counting rates. Birks' coefficient of YAP:Ce was measured to be ($5.56^{+0.05}_{-0.30})\times 10^{-4}$ cm/MeV and light losses due to 120 nm of $^{10}$B-coating to be about 60%. The loss of light from YAP:Ce due to transmission through deuterated polystyrene scintillator was about 50%. The efficiency for counting neutrons that are captured on the $^{10}$B coating is (86.82 $\pm$ 2.61)%. Measurement with ultracold neutrons showed that YAP:Ce crystal counted 8% to 28% more UCNs compared to ZnS screen. This may be due to an uneven coating of $^{10}$B on the rough surface.

physics.ins-det

Scintillation characteristics of the EJ-299-02H scintillator

A study of the dead layer thickness and quenching factor of a plastic scintillator for use in ultracold neutron (UCN) experiments is described. Alpha spectroscopy was used to determine the thickness of a thin surface dead layer, and the relative light outputs from the decay of $^{241}$Am and Compton scattering of electrons were used to extract the quenching parameter. With these characteristics of the material known, the light yield of the scintillator can be calculated. The ability to make these scintillators deuterated, accompanied by its relatively thin dead layer, make it ideal for use in UCN experiment, where the light yield of decay electrons and alphas from neutron capture are critical for counting events.

physics.ins-det

Demonstration of Sub-micron UCN Position Resolution using Room-temperature CMOS Sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work [1, 2] that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully-connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

physics.ins-det

Characterization of the new Ultracold Neutron beamline at the LANL UCN facility

The neutron electric dipole moment (nEDM) experiment that is currently being developed at Los Alamos National Laboratory (LANL) will use ultracold neutrons (UCN) and Ramsey's method of separated oscillatory fields to search for a nEDM. In this paper, we present measurements of UCN storage and UCN transport performed during the commissioning of a new beamline at the LANL UCN source and demonstrate a sufficient number of stored polarized UCN to achieve a statistical uncertainty of $\delta d_n = 2\times 10^{-27}$~$e\cdot\text{cm}$ in 5 calendar years of running. We also present an analytical model describing data that provides a simple parameterization of the input UCN energy spectrum on the new beamline.

physics.ins-det

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.

nucl-ex

Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap

The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.

nucl-ex

Improved neutron lifetime measurement with UCN$\tau$

We report an improved measurement of the free neutron lifetime $\tau_{n}$ using the UCN$\tau$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$\tau$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $\tau_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $\tau_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $\beta$-decay lifetime. Both techniques achieve consistent results and find a value $\tau_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.

nucl-ex

Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment

The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $\beta$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $\beta$-decay electrons are detected with $\approx 4\pi$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $\beta$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.

nucl-ex

A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment

A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.

physics.ins-det

A next-generation inverse-geometry spallation-driven ultracold neutron source

The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-magnitude higher than existing sources, is presented. This UCN-current-optimized source would dramatically improve cutting-edge UCN measurements that are currently statistically limited. A novel "Inverse Geometry" design is used with 40 L of superfluid $^4$He (He-II), which acts as a converter of cold neutrons (CNs) to UCNs, cooled with state-of-the-art sub-cooled cryogenic technology to $\sim$1.6 K. Our design is optimized for a 100 W maximum heat load constraint on the He-II and its vessel. In our geometry, the spallation target is wrapped symmetrically around the UCN converter to permit raster scanning the proton beam over a relatively large volume of tungsten spallation target to reduce the demand on the cooling requirements, which makes it reasonable to assume that water edge-cooling only is sufficient. Our design is refined in several steps to reach $P_{UCN}=2.1\times10^9\,/$s under our other restriction of 1 MW maximum available proton beam power. We then study effects of the He-II scattering kernel as well as reductions in $P_{UCN}$ due to pressurization to reach $P_{UCN}=1.8\times10^9\,/$s. Finally, we provide a design for the UCN extraction system that takes into account the required He-II heat transport properties and implementation of a He-II containment foil that allows UCN transmission. We estimate a total useful UCN current from our source of $R_{use}=5\times10^8\,/$s from a 18 cm diameter guide 5 m from the source. Under a conservative "no return" approximation, this rate can produce an extracted density of $>1\times10^4\,/$cm$^3$ in $<$1000~L external experimental volumes with a $^{58}$Ni (335 neV) cut-off potential.

physics.ins-det

Final results for the neutron $\beta$-asymmetry parameter $A_0$ from the UCNA experiment

The UCNA experiment was designed to measure the neutron $\beta$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.

nucl-ex

The neutron electric dipole moment experiment at the Spallation Neutron Source

Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.

nucl-ex

A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)

A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$\alpha$0$\gamma$)$^7$Li (6%) and $^{10}$B(n,$\alpha$1$\gamma$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $\alpha$, $^7$Li and $\gamma$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.

physics.ins-det